reset MITSUBISHI LANCER EVOLUTION 2011 10.G Owners Manual
[x] Cancel search | Manufacturer: MITSUBISHI, Model Year: 2011, Model line: LANCER EVOLUTION, Model: MITSUBISHI LANCER EVOLUTION 2011 10.GPages: 618, PDF Size: 19.05 MB
Page 241 of 618
3-156 Features and controls
3
Odometer/Trip odometer
N00555400139
Each time you lightly press the multi-information meter
switch, the display screen switches.
Odometer/Trip odometer → Odometer/Trip odometer
→ Service reminder → Redisplay of a warning display screen
→ Odometer/Trip odometer .
Odometer
Shows the total distance traveled.
Trip odometer
Shows the distance traveled between two points.
To reset the trip odometer
To return the display to 0, hold down the multi-information
meter switch for about 2 seconds or more. Only the currently
displayed value will be reset.
Example
If trip odometer is displayed, only trip odometer will
be reset.
NOTEIf there is no warning display, the switching sequence is:
odometer/trip odometer → odometer/trip odometer
→ service reminder → odometer/trip odometer .
Both tripmeters and can count up to 9999.9
miles/kilometers.
When a tripmeter goes past 9999.9 miles/kilometers, it
returns to 0.0 miles/kilometers.
When disconnecting the battery terminal, the memories of
tripmeter displays and are cleared, and their dis-
plays return to “0.0 miles/kilometers”.Service reminder
N00555500013
Shows the distance and number of months until the next peri-
odic inspection.
Refer to “Service reminder” on page 3-169.
Usage examples for trip odometer , trip odometer
It is possible to measure two currently traveled distances,
from home using trip odometer and from a particular
point on the way using trip odometer .BK0123500US.book 156 ページ 2010年6月4日 金曜日 午後5時1分
Page 248 of 618
Features and controls
3-163
3
Average speed displayThis displays the average speed from the last reset to the
present.
There are 2 types of mode settings as follows.
For details on how to change the average speed display setting,
refer to “Changing the function settings (With ignition switch
in the “ON” position)” on page 3-172.
Manual reset mode
When the average speed is being displayed, if you hold
down the multi-information meter switch, these calcula-
tions will be reset to zero.
When the ignition switch is turned to the “ON” position
from the “ACC” or “LOCK” position, the mode setting
changes automatically from manual to auto.
Switching to auto occurs automatically. If switching to
manual mode is done, however, the data from the last
reset is displayed.
Auto reset mode
When the average speed is being displayed, if you hold
down the multi-information meter switch, these calcula-
tions will be reset to zero.
When the ignition switch has been set to the “ACC” or
“LOCK” position for about 4 hours or more, the average
speed display will automatically reset.
NOTEThe average speed display and the average fuel consump-
tion display can be reset separately in both auto reset
mode and manual reset mode.
“---” is displayed when the average speed cannot be mea-
sured.
The initial (default) setting is “Auto reset mode”.
The display setting can be changed to the preferred units
(mph or km/h).
Refer to “Changing the function settings (With ignition
switch in the “ON” position)” on page 3-172.
The average speed display memories for auto reset mode
and manual reset mode are erased if the battery is discon-
nected.Average fuel consumption displayThis displays the average fuel consumption from the last reset
to the present.
There are 2 types of mode settings as follows.
For details on how to change the average fuel consumption dis-
play setting, refer to “Changing the function settings (With
ignition switch in the “ON” position)” on page 3-172.
The “ ” mark in the momentary fuel gauge shows the average
fuel consumption.
Manual reset mode
When the average fuel consumption is being displayed, if
you hold down the multi-information meter switch, these
calculations will be reset to zero.
BK0123500US.book 163 ページ 2010年6月4日 金曜日 午後5時1分
Page 249 of 618
3-164 Features and controls
3
When the ignition switch is turned to the “ON” position
from the “ACC” or “LOCK” position, the mode setting
changes automatically from manual to auto.
Switching to auto occurs automatically. If switching to
manual mode is done, however, the data from the last
reset is displayed.
Auto reset mode
When the average fuel consumption is being displayed, if
you hold down the multi-information meter switch, these
calculations will be reset to zero.
When the ignition switch has been set to the “ACC” or
“LOCK” position for about 4 hours or more, the average
fuel consumption display will automatically reset. NOTEThe average speed display and the average fuel consump-
tion display can be reset separately in both auto reset
mode and manual reset mode.
“---” is displayed when the average fuel consumption can-
not be measured.
The initial (default) setting is “Auto reset mode”.
Average fuel consumption may vary depend on the driv-
ing conditions (road conditions, how you drive, etc.) The
actual fuel consumption may differ from the fuel con-
sumption displayed, so treat the fuel consumption dis-
played as just a rough guideline.
The average fuel consumption display memories for auto
reset mode and manual reset mode are erased if the battery
is disconnected.The display setting can be changed to the preferred units
{mpg (US), mpg (UK), L/100km or km/L}.
Refer to “Changing the function settings (With ignition
switch in the “ON” position)” on page 3-172.
BK0123500US.book 164 ページ 2010年6月4日 金曜日 午後5時1分
Page 250 of 618
Features and controls
3-165
3
Momentary fuel consumption displayWhile driving, the momentary fuel consumption is shown with
a bar graph.
When the momentary fuel consumption surpasses the average
fuel consumption, the momentary fuel consumption is dis-
played with a green bar graph.
Be conscious of maintaining the momentary fuel consumption
above the average fuel consumption, it can help you drive with
the better fuel consumption.NOTEWhen the momentary fuel consumption cannot be mea-
sured, a bar graph is not shown.
The display setting can be changed to the preferred units
{mpg (US), mpg (UK), L/100km or km/L}.
Refer to “Changing the function settings (With ignition
switch in the “ON” position)” on page 3-172.
It is possible to cancel the green bar graph.
Refer to “Changing the function settings (With ignition
switch in the “ON” position)” on page 3-172.S-AWC operation displayThe S-AWC operation status is displayed.
For further details, refer to “S-AWC operation display” on
page 3-122.
Function setting screenThe “Display language”, “Temperature unit”, “Fuel consump-
tion unit”, and “Average fuel consumption and speed reset
method” settings can be modified as desired.
For further details, refer to “Changing the function settings
(With ignition switch in the “ON” position)” on page 3-172.
WA R N I N G
!Always concentrate on your driving first. Keep your
eyes and mind on the road. Distractions while driv-
ing can lead to an accident.
BK0123500US.book 165 ページ 2010年6月4日 金曜日 午後5時1分
Page 255 of 618
3-170 Features and controls
3
2. This informs you that a periodic inspection is due. Contact
an authorized Mitsubishi Motors dealer or a repair facility
of your choice to have the system checked.
At that time, when the ignition switch is switched from
the “OFF” position to the “ON” position, “PERIODIC
INSPECTION” is displayed for a few seconds on the
information screen.
3. After your vehicle is inspected at an authorized Mitsubishi
Motors dealer, it displays the time until the next periodic
inspection.
To reset The “---” display can be reset while the ignition switch is in the
“OFF” position. When the display is reset, the time until the
next periodic inspection is displayed and the warning display is
no longer displayed when the ignition switch is switched from
the “OFF” position to the “ON” position.
1. When you lightly press the multi-information meter
switch, the information screen switches to the service
reminder display screen.
BK0123500US.book 170 ページ 2010年6月4日 金曜日 午後5時1分
Page 256 of 618
Features and controls
3-171
3
2. Press and hold the multi-information meter switch (for
about 2 seconds or more) to display “ ” and make it
flash. (If there is no operation for about 10 seconds with
this indicator flashing, the display returns to the previous
screen.)
3. With this indicator flashing, if you lightly press the multi-
information meter switch, the screen switches from “---”
to “CLEAR”. After that, the time until the next periodic
inspection is shown.
NOTEThe “---” display cannot be reset while the ignition switch
is in the “ON” position.
When “---” is displayed, after a certain distance and a cer-
tain period of time, the display is reset and the time until
the next periodic inspection is displayed.
If you accidentally reset the display, consult an authorized
Mitsubishi Motors dealer for assistance.
CAUTION
!The customer is responsible for making sure that
regular inspections and maintenance and periodic
inspections and maintenance are performed.
Inspections and maintenance must be performed to
prevent accidents and malfunctions.
BK0123500US.book 171 ページ 2010年6月4日 金曜日 午後5時1分
Page 258 of 618
Features and controls
3-173
3
3. Press and hold the multi-information meter switch (for
about 2 seconds or more) to switch from the setting mode
screen to the menu screen.
NOTETo return the menu screen to the function setting screen,
press and hold the multi-information meter switch (for
about 2 seconds or more).
If no operations are made within about 15 seconds of the
menu screen being displayed, the display returns to the
function setting screen.
4. Select the item to change on the menu screen and change
to the desired setting. For further details on the operation
methods, refer to the following sections.
Refer to “Changing the reset mode for average fuel con-
sumption and average speed” on page 3-174.
Refer to “Changing the fuel consumption display unit” on
page 3-175.
Refer to “Changing the temperature unit” on page 3-176.
Refer to “Changing the display language” on page 3-177.
Refer to “Changing the language on Mitsubishi Multi-
Communication System or Bluetooth
® 2.0 interface to
match the multi-information display (if so equipped)” on
page 3-178.
Refer to “Operation sound setting” on page 3-179.
Refer to “Changing the time until “REST REMINDER” is
displayed” on page 3-180.
Refer to “Changing the turn signal sound” on page 3-181.
Refer to “Changing the momentary fuel consumption dis-
play” on page 3-182.
Refer to “Returning to the factory settings” on page 3-
182.
CAUTION
!For safety, stop the vehicle before operating.
While driving, even if you operate the multi-infor-
mation meter switch, the function setting screen is
not displayed.
BK0123500US.book 173 ページ 2010年6月4日 金曜日 午後5時1分
Page 259 of 618
3-174 Features and controls
3
Changing the reset mode for average fuel consumption
and average speed
N00557000155
You can change the mode condition for the average fuel con-
sumption and average speed display to “Auto reset” or “Man-
ual reset.”
1. Press and hold the multi-information meter switch (for
about 2 seconds or more) to switch from the setting mode
screen to the menu screen.
Refer to “Changing the function settings (With ignition
switch in the “ON” position)” on page 3-172.
2. Lightly press the multi-information meter switch to select
“AVG” (average fuel consumption and average speed set-
ting).3. Press and hold the multi-information meter switch (for
about 2 seconds or more) to switch in sequence from A
(Auto reset) → M (Manual reset) → A (Auto reset).
The setting is changed to the selected reset condition.
Manual reset mode
If you press and hold the multi-information meter switch
when the average fuel consumption and average speed are
displayed, these calculations will be reset to zero.
When the ignition switch is turned to the “ON” position
from the “ACC” or “LOCK” position, the mode setting
changes automatically from manual to auto.
Switching to auto occurs automatically. If switching to
manual mode is done, however, the data from the last
reset is displayed.
Auto reset mode
When the average fuel consumption and average speed
are being displayed, if you hold down the multi-informa-
tion meter switch, these calculations will be reset to zero.
When the ignition switch has been set to the “ACC” or
“LOCK” position for about 4 hours or more, the average
fuel consumption display and the average speed display
will automatically reset.
NOTEThe average speed display and average fuel consumption
display can be reset separately in both auto reset mode and
manual reset mode.
The average speed display memories and average fuel
consumption memories for auto reset mode and manual
reset mode are erased if the battery is disconnected.
The initial (default) setting is “Auto reset mode”.
BK0123500US.book 174 ページ 2010年6月4日 金曜日 午後5時1分
Page 266 of 618
Features and controls
3-181
3
3. Press and hold the multi-information meter switch (for
about 2 seconds or more) to display “ALARM” (rest time
setting).
4. Lightly press the multi-information meter switch to select
the time until the display appears.
5. Press and hold the multi-information meter switch (for
about 2 seconds or more) to change the setting to the
selected time.NOTEIf the battery is disconnected, the memory of the unit set-
ting is erased and is automatically set to the “OFF”.
The drive time is reset when the ignition switch is in the
“OFF” position.
Changing the turn signal sound
N00563500067
It is possible to change the turn signal sound.
1. Press and hold the multi-information meter switch for
about 2 seconds or more to switch from the setting mode
screen to the menu screen.
Refer to “Changing the function settings (With ignition
switch in the “ON” position)” on page 3-172.
2. Lightly press the multi-information meter switch to select
. (changing the turn signal sound)
3. Press and hold the multi-information meter switch for
about 2 seconds or more to switch in sequence from 1
(turn signal sound 1) → 2 (turn signal sound 2) → 1 (turn
signal sound 1).
The setting changes to the selected turn signal sound.
BK0123500US.book 181 ページ 2010年6月4日 金曜日 午後5時1分
Page 267 of 618
3-182 Features and controls
3
Changing the momentary fuel consumption display
N00563600026
It is possible to change the bar graph setting of the momentary
fuel consumption display.
1. Press and hold the multi-information meter switch for
about 2 seconds or more to switch from the setting mode
screen to the menu screen.
Refer to “Changing the function settings (With ignition
switch in the “ON” position)” on page 3-172.
2. Lightly press the multi-information meter switch to select
. (changing the momentary fuel consumption display)
3. Press and hold the multi-information meter switch for
about 2 seconds or more to switch in sequence from ON
(with the green bar graph) → OFF (without the green bar
graph) → ON (with the green bar graph).
The setting changes to the selected bar graph setting.
Returning to the factory settings
N00557600177
All of the function settings can be returned to their factory set-
tings.
1. Press and hold the multi-information meter switch (for
about 2 seconds or more) to switch from the setting mode
screen to the menu screen.
Refer to “Changing the function settings (With ignition
switch in the “ON” position)” on page 3-172.
2. Lightly press the multi-information meter switch to select
“RESET” (return to the factory settings).
BK0123500US.book 182 ページ 2010年6月4日 金曜日 午後5時1分