AUDI A6 2000 C5 / 2.G AHA Engine Multiport Fuel Injection And Ignition System Workshop Manual
Page 151 of 166
24-116
      
Evaporative Emissions (EVAP) canister 
purge regulator valve, checking
 
     
WARNING! 
     
Whenever carrying out work on the fuel 
supply and/or fuel injection systems, read 
and carefully follow the Cautions, Warnings, 
and rules of cleanliness   page 24-9 . 
     
Note:  
     Component locations   page 24
-1  
     
Required special tools and test equipment  
     
VAG1551 or VAG1552 Scan Tool (ST) with 
VAG1551/3 adapter cable 
     
Test conditions  
     Engine coolant temperature at least 80 C 
(176 F) 
     
Function check  
     
-  Connect VAG1551 or VAG1552 scan tool and 
press buttons -0- and -1- to insert "Engine 
Electronics" address word 01 (with engine 
running at idle)   page 01
-8 . 
Pa
ge 151 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1 
Page 152 of 166
Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
Pa
ge 152 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1 
Page 153 of 166
24-117
      
-  Press buttons -0- and -8- to select "Read 
Measuring Value Block" function 08, and press -
Q- button to confirm input. Read Measurin
g Value Block 
HELP
Input displa
y group number XXX
    
Indicated on display  
-  Press buttons -0-, -7- and -0- to input display group number 70 (070), 
and press -Q- button to confirm input. 
Read Measuring Value Block 70 1 2 3 4 
    
Indicated on display (1-4 = display fields)  
Note:  
During this diagnosis there should not be any load placed on the engine, 
otherwise the diagnosis is interrupted and must be started again.  -  Press button -4- to select "Basic Setting" function 04 (diagnosis for 
EVAP canister purge regulator valve is initiated). 
System in Basic Setting 70 1 2 3 4 
    
Indicated on display (1-4   display fields)  
If the diagnosis is initiated by the ECM, the display changes from "Test 
OFF" to "Test ON" in display field 4.  
Note:  
If the display changes from "Test ON" to "Test OFF" during the test, 
accelerate with a brief burst to repeat the test. -  Continue to run engine at idle until "EVAP OK" is indicated in display 
field 4. 
Pa
ge 153 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1 
Page 154 of 166
24-118
 
  
Display fields  
  
1   2   3   4  
Display group 70: EVAP canister purge regulator valve  
Display   xxx %   xx.x %   xx.xx g/s   Test OFF/Test 
ON  
EVAP OK  
EVAP n.OK  
Indicated   EVAP canister purge regulator 
valve duty cycle during diagnosis  Oxygen sensor deviation 
during diagnosis  Idle Air Control (IAC) valve 
deviation during diagnosis  Diagnosis 
condition  
Diagnosis 
results  
Range   0 - 100 %   -25.0 to +25.0 %   -2.70 to +4.16 g/s   ---  
Specified 
value  0 - 93 %   - 15.0 to +15.0 %   1.00 - 0.00 g/s   EVAP OK        If "EVAP n.OK" is indicated in display field 4:  
     
-  Check for blockage or leaks   page 24
-119
 .
      If "EVAP OK" is indicated in display field 4:  
     
- 
Press  button.Rapid data transfer 
HELP
    
Indicated on display  
Pa
ge 154 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1 
Page 155 of 166
Select function XX
-  Press buttons -0- and -6- to select "End Output" function 06, and 
press -Q- button to confirm input. 
Pa
ge 155 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1 
Page 156 of 166
24-119
      
Checking for blockage and leaks  
      The EVAP canister purge regulator valve is 
closed when power is off.  
     
-  Remove EVAP canister purge regulator valve -
N80- (component locations   page 24
-1 ) 
     
-  Connect removed valve to harness connector.
     
-  Start output Diagnostic Test Mode (DTM) and 
select -N80-   page 01
-51
 . 
     
-  Blow into long connection during output DTM, 
and check whether valve opens and closes 
properly. Replace valve if necessary. 
      If valve -N80- does not open and close as 
specified:  
     
- Replace -N80-. 
      If valve -N80- is OK:  
     
-  Check all hose connections between tank and 
valve for blockage or leaks. 
Pa
ge 156 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1 
Page 157 of 166
24-120
      
EVAP canister purge regulator valve -N80- 
electrical test  
     
-  Disconnect harness connector from EVAP 
canister purge regulator valve. 
    
If resistance is NOT OK:  -  Connect multimeter US1119 (Fluke 83 or equivalent) and check 
resistance at across valve terminals. 
  
Specified value: 22-30   -  Replace EVAP canister purge regulator valve
Pa
ge 157 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1 
Page 158 of 166
24-121
      
Checking EVAP canister purge regulator 
valve voltage supply  
     
Test conditions  
     
Fuse for EVAP canister purge regulator 
valve OK 
     
-  Disconnect harness connector from EVAP 
canister purge regulator valve. 
    
If LED test light does not light:  
If wiring is OK:  -  Connect VAG1527B LED voltage tester between connector terminal 1 
(B+) and engine Ground. 
-  Operate starter motor. 
   Specified value: LED must light up
-  Check wiring for open circuit between connector terminal 1 and fuse, 
according to wiring diagram; repair if necessary. 
  
Specified value: 1.0   max.-  Check fuel pump relay   page 24
-95
 .
Pa
ge 158 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1 
Page 159 of 166
24-122
      
Checking signal to EVAP canister purge 
regulator valve  
    
If LED test light does not blink, or stays on:  
If LED test light does not blink:  -  Connect VAG1527B LED voltage tester between connector terminals 1 
(B+) and 2. 
-  Start output Diagnostic Test Mode (DTM) for EVAP canister purge 
regulator valve -N80-   page 01
-51
 . 
   LED must blink
-  Connect VAG1598/22 test box to ECM harness connector   page 01
-
67
 . 
    
If LED test light stays on:  -  Check wiring between connector terminal 2 and Motronic ECM terminal 
15 for open circuit or short circuit to B+. 
-  Check wiring between connector terminal 2 and Motronic ECM terminal 
15 for short circuit to Ground. 
Pa
ge 159 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1 
Page 160 of 166
24-123
       If wiring is OK:  
     
-  Replace Motronic ECM -J220-   page 01
-68
 .
     
-  Carry out adaptation of throttle valve control 
module to ECM   page 24
-150
 . 
     
- Check readiness code   page 01
-70
 . If 
Diagnostic Trouble Code (DTC) memory has 
been erased, or ECM was disconnected, 
generate new readiness code   page 01
-73
 . 
Pa
ge 160 of 166 Motronic Multi
port Fuel In
jection 
(MFI
) and i
gnition s
ystem
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU03.24.1