AUDI A8 2003 D3 / 2.G Technical Features Manual
Page 91 of 96
Downloaded from www.Manualslib.com manuals search engine 91
4.2 Auxiliary heating sequence
The level of fuel in the tank is
interrogated. If the fuel tank is "empty",
the auxiliary heating function is not
permitted and the auxiliary heater symbol
in the dash panel insert goes out. "Empty"
roughly corresponds to the red display
zone. The energy management control
unit J644 checks whether there is
sufficient energy to accept auxiliary
heating. If this is the case, the auxiliary
heater is switched on in the various
operating modes depending on the
characteristic temperature curve and the
fresh-air blower is actuated.
If the auxiliary heating temperature
reaches a level of 30 °C, the fresh-air
blower is activated and the coolant
shutoff valve N279 pulsed in line with the
characteristic curve.
The auxiliary heater is switched off
automatically on completion of the operating
time transmitted by the MMI system to the
Climatronic control unit or it can be switched
off using the remote control OFF button.
Auxiliary heater circulation pump control
To speed up heating of the passenger
compartment and to achieve a better "heat
yield" in the air conditioner unit heat
exchanger, the circulation pump V55 and
coolant shutoff valve N279 are pulsed as a
function of water temperature and the
heating circuit flow rate is thus reduced.
An electric circulation pump is used for the
auxiliary heater. It is not possible to reduce
the supply voltage in the auxiliary heater
control unit and the circulation pump is thus
actuated at specific intervals to decrease its
output.
Additional control curve for "auxiliary heater"
and "additional heater"
When the engine is on, the auxiliary heater
and engine temperatures are constantly
compared. A switch to the large coolant
circuit is made as soon as the engine
temperature exceeds the auxiliary heater
temperature.
Activation of auxiliary heater circulation
pump with engine on
(pulsed operation of circulation pump)
In order to be able to ensure a sufficient flow
of water through the heat exchanger, the
auxiliary heater circulation pump must
additionally be switched on, as is the case for
instance with the 12-cylinder engine.If the engine is switched off again and not
all additional heater criteria (temperature,
time) are satisfied, the auxiliary heater
remains in operation for any residual
operating time before being deactivated.
This function can be encoded.
Page 92 of 96
Downloaded from www.Manualslib.com manuals search engine 92
Small coolant circuit with auxiliary heater
The small coolant circuit employed with
auxiliary heating is designed to ensure rapid
warming of the passenger compartment.
With the engine stopped, the coolant shutoff
valve N279 switches to the small heating
circuit until a defined temperature value has
been attained. The coolant exiting from the
heat exchangers via the pump/valve unit is
conveyed by the circulation pump V55 into
the auxiliary heater. After being warmed, the
coolant is pumped back into the heat
exchangers and initially heats the passenger
compartment.
Heating/Air Conditioner
SSP282_097
Design and operation are described in
SSP 267 – The 6.0 l W12 engine in the
Audi A8 - Part 1.
Coolant shutoff
valve N279
Circulation pump V55Auxiliary heater with
additional heater control unit J364
Non-return valve 2
Continued coolant
circulation pump V51 Tempera-
ture
senderPump/valve unit with
heating-system heat
exchangers Cap
Coolant
circulation
pump V50
Page 93 of 96
Downloaded from www.Manualslib.com manuals search engine 93
Notes
Page 94 of 96
Downloaded from www.Manualslib.com manuals search engine 94
Notes
Page 95 of 96
Downloaded from www.Manualslib.com manuals search engine
Page 96 of 96
Downloaded from www.Manualslib.com manuals search engine Service.
For internal use only All rights reserved. Subject to
technical modification.
Copyright* 2002 AUDI AG, Ingolstadt
Department I/VK-35
D-85045 Ingolstadt
Fax 0841/89-36367
000.2811.02.20
Technical status as at 09/02
Printed in Germany
AUDI A8 ´03 - Technical Features
Self Study Programme 282
282
282