aircon Citroen XSARA PICASSO 2004 1.G User Guide

Page 483 of 523

Downloaded from www.Manualslib.com manuals search engine 479
ELECTRICAL
SYSTEM
ALTERNATORS
Allocation of alternator classes
XSARA PICASSO
Meaning of abbreviations, see page:472.
Without aircon With aircon
Heated Nav. + Heated Nav. +
Engine Gearbox Climate Base seat Nav. Heated seat Base seat Nav. Heated seat
C
1.6i T
78+BVMF8+GF
C121.8i 16VT
8+BVM F
GF
C
122.0i 16V T
BVA F8+
8+GF
C
1.6 HDi 16V T
2.0 HDi F
15 15GF

Page 487 of 523

Downloaded from www.Manualslib.com manuals search engine 483
TU EW
DW
XU10
TU
EW7 DW10
BRESIL ALL TYPES
590 gr + 0 50 gr
725 gr + 0 50 gr
675 gr ± 50 gr
775 gr ± 25 gr
AIR CONDITIONING R 134 a (HFC)
Vehicle Engines DateRefrigerant
refillCompressor
Variable
CapacityOil quantity cc
Oil reference
AIRCON
C2
SD 6 V 12
SD 7 V 16
SD 6 V 12
SD 7 V 16135 SP 10
12/1999
#
03/2001 #
XSARA
XSARA
PICASSO
ALL TYPES 05/2003 #600 + 0 50 gr
09/2000
#
C3ALL TYPES11/2001 #625 + 0 50 grC3 Pluriel

Page 488 of 523

Downloaded from www.Manualslib.com manuals search engine 484
ELECTRICAL
SYSTEM
C5HP073C
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Clickfit connector removing/fitting tool
Ø Inch
V ehicle
XSARA
XSARA
PICASSOTT
BP
HP5/8Black
8005T.A
3/8Red
8005T.C Ring colour Tool kit 4164T
Tightening torques (m.daN).
Unions
Steel/Steel
Aluminium/Steel Ø Pipes
1,7 ±0,3
1,3 ± 0,3 M 06
3,8 ± 0,3
2 ± 0,2
M 08
4 ± 0,3
2,5 ± 0,3 M 10
NOTE:Tighten the union to the recommended torque using a retaining spanner whenever possible.
NOTE:For operations concerning draining, drying (empty), checking and recharging of a system:refer to BRE 0290.
WARNING: For R 134.a quantities (see table on preceding page:483).
Aircon compressor fixings.
ESSENTIAL: Tighten the front part of the compressor(timing belt end), before the rear part of the compressor.

Page 489 of 523

Downloaded from www.Manualslib.com manuals search engine 485
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Compressor (MANULLI seal)
«EUR OCLIM»
Tools.
Tool for removingrefitting air conditioning seals: FACOM ().1702
IMPERATIVE: Removingrefitting the MANULLI seal
(see corresponding operation).
MANULLI seal.
C2 C3 : All engineversions
XSARA
(Compressor and condenser end): 08/2000 #
XSARA PICASSO
(Compressor end):11/2002 #
Engineversions:
NFV : 10/12/2001
#
6FZ : 01/04/2002 #
RHY: 04/11/2002 #
Aircon compressor.
XSARA PICASSOengine versions:6FZ and RHY
Discontinuation
of compressor SD 6 V 12
Replaced
by compressor SD 7 V 16: 04/11/2002#
C2 C3 XSARA PICASSO
The drive plate (1)is held on the aircon compressor shaft by ribs.
New wiring
(2).
New seals
(3) (MANULLI).
Identification label
(4) for aircon compressor.
AIRCONC5HP18UD

Page 490 of 523

Downloaded from www.Manualslib.com manuals search engine 486
ELECTRICAL
SYSTEM
MANULLI calibrated seal (3).
Direction of fitting of the seal (3).
Before fitting the seal, amply lubricate the seal with air conditioningcompressor oil
(SP10). The condenser
(5)has a cylinder (6)incorporating the function of aircon
fluid reservoir and with integral filtering cartridge.The inlet
(7)and the outlet (8)of the condenser (5)are equipped with
new seals (3) (MANULLI).
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Seals (MANULLI seal)
Condenser (MANULLI seal)
C5HP18VDC5HP18XD
C2 C3 XSARA PICASSO

Page 491 of 523

Downloaded from www.Manualslib.com manuals search engine 487
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Presence of pollen filter
Vehicle Equipment RPO No. Presence of filter Observations
SAXO
C2 C3ALL TYPESNO
YES
YES
(Behr)
YES (Larger)
YES (Valéo)
NO(Valéo)
YES (Valéo)
Without aircon
Base aircon
Regulated airconWithout aircon
Base airconXSARA
XSARA PICASSO
BERLINGOExcept driving school
AIRCON

Page 494 of 523

Downloaded from www.Manualslib.com manuals search engine 490
AIRCONAIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Tools.
[1]
Charge station :(according to workshop equipment)[2]TORX adaptor: TORX 70 FACOM
[3]Inertia extractor:1671T Tool kit 4114T
[4]Endpiece Ø 20 : 1671T.D20
[5]Set of plugs: ().0188.T
[6]Circlip pliers: FACOM
Removing.
Depressurise the aircon circuit, using tool [1].
Remove the grille.At
«a», remove the pin and the plastic cover.
Unclip the condenser at «b»and «c», using a screwdriver.
Tilt the condenser towards the front.
Lift and release the condenser.Clean the area around the cap
(3).
Remove the plastic cap (3), using tool [2].
Remove the safety circlip (4), using tool [6].
Position the tool [3]and[4]in the aperture of the cartridge (5).
Extract the cartridge from the reservoir (6), using tool [3]and [4].
Block the reservoir (6), using tool [5].
C4AP163CC4AP164CC4AP166CC4AP165C
C2 C3 C3 PLURIEL

Page 495 of 523

Downloaded from www.Manualslib.com manuals search engine 491
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Changing the filtering/drying cartridge
Refitting.
Remove the new cartridge from its packaging.
Do not expose the cartridge, the filter and seals to pollutants.
Lightly oil the seals
(compressor oil).
Remove tool [5] from the reservoir (6).
Insert the new cartridge (5)into the reservoir (6).
Refit the safety circlip (4), using tool [6].
Make sure that the circlip (4)is correctly positioned in its location.
WARNING: Not more than 5 minutes should elapse between the removal of
the cartridge (6) from its packaging and its being fitted.
Refit:
The plastic cap (3), using tool [5] Tighten to 1,2 ±0,1 m.daN.
The condenser (reclip, pushing at «b»and «c»).
The plastic cover and the pins at «a».
The grille (2).
The screws (1).
Proceed to:
Recharge the circuit
(see corresponding operation).
Check the operation of the air conditioning (see corresponding operation).
C4AP167CC4AP165CC4AP164CC4AP163C
C2 C3 C3 PLURIEL

Page 496 of 523

Downloaded from www.Manualslib.com manuals search engine 492
AIRCONAIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Pollen filter
XSARA
Removingrefitting.
Remove:
The interior trim (1).
The cover (4).
The pollen filter(3).
Concerns vehicles equipped with aircon without temperature regulation.
Fitting of a new pollen filter necessitates the following operations:
Engage the pollen filter upwards (following arrow «c»).
Slide the pollen filter towards the rear (following arrow «d»).
Position the index (4)on the cover forward of the pollen filter((4)Index on the cover).
C5HP07JC
C5FP075D

Page 497 of 523

Downloaded from www.Manualslib.com manuals search engine 493
AIRCON
SPECIAL FEATURES: AIR CONDITIONING SYSTEM (R 134.a)
Pollen filter
Remove:
The three screws (1).
The cover
(2).
Remove the pollen filter.
XSARA PICASSO