TF-24
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
DATA MONITOR MODE
Operation Procedure
1. Perform “CONSULT-II Start Procedure”. Refer to GI-38, "CONSULT-II Start Procedure" .
2. Touch “DATA MONITOR”.
3. Select from “SELECT MONITOR ITEM”, screen of data monitor mode is displayed. NOTE:
When malfunction is detected, CONSULT-II performs REAL-TIME DIAGNOSIS.
Also, any malfunction detected while in this mode will be displayed at real time.
Display Item List
× : Standard –: Not applicable
Monitored item (Unit) Monitor item selection
Remarks
ECU INPUT
SIGNALS MAIN
SIGNALS SELECTION
FROM MENU
FR RH SENSOR [km/h] or [mph] ××× Wheel speed calculated by front wheel
sensor RH signal is displayed.
FR LH SENSOR [km/h] or [mph] ××× Wheel speed calculated by front wheel
sensor LH signal is displayed.
RR RH SENSOR [km/h] or [mph] ××× Wheel speed calculated by rear wheel
sensor RH signal is displayed.
RR LH SENSOR [km/h] or [mph] ××× Wheel speed calculated by rear wheel
sensor LH signal is displayed.
BATTERY VOLT [V] – – ×Power supply voltage for AWD control unit
THRTL POS SEN [%] – – ×Throttle opening status is displayed.
ETS SOLENOID [A] – – × Monitored value of current at AWD sole-
noid
STOP LAMP SW [ON/OFF] – – × Stop lamp switch signal status via CAN
communication line is displayed.
ENG SPEED SIG [RUN/STOP] – – ×Engine status is displayed.
ETS ACTUATOR [ON/OFF] – – × Operating condition of AWD actuator relay
(integrated in AWD control unit) is dis-
played.
4WD WARN LAMP [ON/OFF] – – × Control status of AWD warning lamp is dis-
played.
4WD MODE SW [AUTO] – – × AWD lock switch is not equipped, but dis-
played.
4WD MODE MON [AUTO] – – ×Control status of AWD is displayed.
DIS-TIRE MONI [mm] – – × Improper size tire installed condition is dis-
played.
P BRAKE SW [ON/OFF] – – × Parking switch signal status via CAN com-
munication line is displayed.
Voltage [V] – – × The value measured by the voltage probe
is displayed.
Frequency [Hz] – – ×
The value measured by the pulse probe is
displayed.
DUTY-HI (high) [%] – –
×
DUTY-LOW (low) [%] – – ×
PLS WIDTH-HI [msec] – – ×
PLS WIDTH-LOW [msec] – – ×