engine RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16C36 Workshop Manual

Page 152 of 431

13B-152
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF249
CONTINUED
This fault appears when the computer detects a fault on the injector control section
Check the condition of the injector connectors (see Wiring Diagram Technical Note, Mégane II ph2, Scénic II
ph2, Component codes 193, 194, 195, 196).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity and insulation of the following connections:
– Connection code 3KW between components 193 and 120.
– Connection code 3CR between components 193 and 120.
– Connection code 3KX between components 194 and 120.
– Connection code 3CS between components 194 and 120.
– Connection code 3KY between components 195 and 120.
– Connection code 3CT between components 195 and 120.
– Connection code 3KZ between components 196 and 120.
– Connection code 3CU between components 196 and 120.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 153 of 431

13B-153
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF272
PRESENT
OR
STOREDEGR VALVE CONTROL CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
CC: Short circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on.
– the engine is started,
– a road test.
Special notes:
If the fault is present:
–the European On Board Diagnostic warning light is lit,
– there is smoke from the exhaust.
Use bornier Ele. 1681 for all operations on the engine management computer
connector.
For EGR valves with a flat connector, it is not possible to check the sensor resistance.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF272/EDC16C36_V4C_DF272/EDC16C36_V48_DF272/EDC16C36_V50_DF272/EDC16C36_V54_DF272/
EDC16C36_V58_DF272EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 154 of 431

13B-154
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF272
CONTINUED 1
CONOTESNone.
Check the condition of the connector of the EGR valve (see Wiring Diagram Technical Note, Mégane II ph2,
Scénic II ph2, Component code 1460).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity of the following connections:
– Connection code 3VP between components 1460 and 120.
– Connection code 3VQ between components 1460 and 120.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EGR valve with a square connector:
Measure the resistance of the EGR valve between the following connections:
– Connection code 3VP of component 1460.
– Connection code 3VQ of component 1460.
EGR valve with a flat connector:
Replace the EGR valve.
Replace the valve if the resistance is not between 1 Ω<X<400 Ω.
When replacing the EGR valve, run command SC036 Reinitialise programming and select EGR valve to
reinitialise the EGR valve offsets (see Replacement of components).
If the fault is still present, contact the Techline.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 155 of 431

13B-155
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF272
CONTINUED 2
CC.0
CC.1NOTESNone.
Check the condition of the connector of the EGR valve (see Wiring Diagram Technical Note, Mégane II ph2,
Scénic II ph2, Code organe1460).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation from + 12 V of the following connections:
– Connection code 3VP between components 1460 and 120.
– Connection code 3VQ between components 1460 and 120.
Check the insulation against +5 V (computer supplies) of the following connections:
– Connection code 3VP between components 1460 and 120.
– Connection code 3VQ between components 1460 and 120.
Check the insulation against earth of the following connections:
– Connection code 3VP between components 1460 and 120.
– Connection code 3VQ between components 1460 and 120.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EGR valve with a square connector:
Measure the resistance of the EGR valve between the following connections:
– Connection code 3VP of component 1460.
– Connection code 3VQ of component 1460.
EGR valve with a flat connector:
– Replace the EGR valve.
Replace the valve if the resistance is not between 1 Ω<X<400 Ω.
When replacing the EGR valve, run command SC036 Reinitialise programming
and select EGR valve to
reinitialise the EGR valve offsets (see Replacement of components).
If the fault is still present, contact the Techline.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 156 of 431

13B-156
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF272
CONTINUED 3
CCNOTESNone.
Check the condition of the connector of the EGR valve (see Wiring Diagram Technical Note, Mégane II ph2,
Scénic II ph2, Component code 1460).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation between the following connections:
– Connection code 3VP between components 1460 and 120.
– Connection code 3VQ between components 1460 and 120.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EGR valve with a square connector:
Measure the resistance of the EGR valve between the following connections:
– Connection code 3VP of component 1460.
– Connection code 3VQ of component 1460.
EGR valve with a flat connector:
– Replace the EGR valve.
Replace the valve if the resistance is not between 1 Ω<X<400 Ω.
When replacing the EGR valve, run command SC036 Reinitialise programming and select EGR valve to
reinitialise the EGR valve offsets (see Replacement of components).
If the fault is still present, contact the Techline.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 157 of 431

13B-157
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF276
PRESENT
OR
STOREDINJECTOR CODE PROGRAMMING
1.DEF: No code stored
2.DEF: Internal electronic fault during programming
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the ignition has been switched on.
Special notes:
If the fault is present,
– torque limited, engine speed limited to 1500 rpm,
– engine torque limited,
–the level 1 warning light is illuminated.
Use bornier Ele. 1681 for all operations on the engine management computer
connector.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
1.DEF
2.DEF
NOTESThis fault appears:
– when an incorrect injector code has been entered using
command SC002 Enter injector codes,
– after replacing the injection computer,
– after (re)programming.
EDC16C36_V44_DF276/EDC16C36_V4C_DF276/EDC16C36_V48_DF276/EDC16C36_V50_DF276/EDC16C36_V54_DF276/
EDC16C36_V58_DF276EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 159 of 431

13B-159
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF293
PRESENT
OR
STOREDWATER IN DIESEL FUEL SENSOR
1.DEF: Open circuit on the line or water present in the diesel fuel
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on,
– a road test.
Special notes:
If the fault is present,
– risk of engine destruction if fault DF293 not taken into account,
– water in diesel warning light on.
Use bornier Ele. 1681 for all operations on the engine management computer
connector.
IMPORTANT
Please observe the cleanliness guidelines and safety advice.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF293/EDC16C36_V4C_DF293/EDC16C36_V48_DF293/EDC16C36_V50_DF293/EDC16C36_V54_DF293/
EDC16C36_V58_DF293EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 160 of 431

13B-160
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF293
CONTINUED
Make sure that there is no water in the diesel filter.
Bleed the diesel filter and the low and high pressure diesel circuits, if necessary (see MR 364 (Mégane) or 370
(Scénic), Mechanical, 13A, Fuel supply, and 13B, Diesel injection).
If the diesel filter contains a large amount of water, apply the first part of the Test 11: Diesel fuel conformity check
(Is the fuel cloudy or does it separate into 2 parts?)
Start the engine and wait at least 1 minute to confirm the repair.
If the fault was stored but not present, carry out a road test (see Note).
If the fault does not reappear, end of fault finding procedure.
Check the continuity, insulation and the absence of interference resistance of the following connection:
– Connection code 3WT between components 414 and 120.
Check the +12 V after relay feed of the water detection sensor:
– Connection code3FB of component414.
Check the earth of the water detection sensor:
– Connection code NT of component 414.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
– Start the engine and wait at least 1 minute to confirm the repair.
Check the conformity of the fuel used by running test 11 Diesel fuel conformity check.
If none of these checks reveal any faults:
– Replace the water detection sensor,
– clear the fault,
– start the engine and wait at least 1 minute to confirm the repair.
Note:
When the water level in the fuel filter unit is below the sensor's electrodes, some driving conditions (cornering,
gradients) may result in water being detected (in fact, the sensor's off-centre position in the fuel filter unit, combined
with the driving conditions, causes water to be detected).
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 161 of 431

13B-161
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
*diff: differential
*temp: temperature
DF308
PRESENT
OR
STOREDCLOGGED PARTICLE FILTER
NOTESConditions for applying fault finding procedures to stored faults:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– the EGR function is inhibited,
– the vehicle performance is reduced,
–the level 1 warning light is lit and a warning message (or light) is displayed on the
instrument panel.
Priorities when dealing with a number of faults:
Deal with the following faults first:
– DF315 Particle filter differential pressure sensor if it is present.
– DF308 if DF315 is stored.
– DF316 Particle filter diff* pressure sensor if it is present or stored.
– DF226 Damper valve circuit if it is present or stored.
– DF272 EGR valve control circuit if it is present or stored.
– DF647 EGR valve position regulation if it is present or stored.
– DF309 Particle filter downstream temperature sensor if it is present or stored.
– DF899 Regeneration temperature threshold exceeded if it is present or stored.
– DF310 Particle filter upstream temperature sensor if it is present or stored.
– DF778 Turbine upstream temperature regulation if it is present or stored.
– DF652 Turbine upstream temperature sensor circuit if it is present or stored.
EDC16C36_V48_DF308/EDC16C36_V50_DF308/EDC16C36_V58_DF308EDC16 C36
Program No.: 91
Vdiag No.: 48, 50, 58

Page 163 of 431

13B-163
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
V9 MR-372-J84-13B450$103.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
*temp: temperature
DF309
PRESENT
OR
STOREDPARTICLE FILTER DOWNSTREAM TEMP.* SENSOR
CO.1: Open circuit or short circuit to +12 V
CC.0: Short circuit to earth
NOTESConditions for applying fault finding procedures to stored faults:
The fault becomes present if:
– ignition is on (CC.0),
– following a road test, engine warm (CO.1).
IMPORTANT
The particle filter downstream temperature sensor only measures temperatures
greater than 50°C.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.0
NOTESNone.
Check the condition of the particle filter downstream temperature sensor connector.
Check the condition of the engine management computer connector.
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the insulation from earth of the following connections:
– connection code3TG,
– connection code3XU,
between components 120 and 1288.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the particle filter downstream temperature sensor.
EDC16C36_V48_DF309/EDC16C36_V58_DF309EDC16 C36
Program No.: 91
Vdiag No.: 48, 58

Page:   < prev 1-10 ... 91-100 101-110 111-120 121-130 131-140 141-150 151-160 161-170 171-180 ... 360 next >