fuses RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16C36 Workshop Manual

Page 64 of 431

13B-64V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF025
PRESENT
OR
STOREDPRE-POSTHEATING UNIT DIAGNOSTIC LINE
1.DEF: Faulty heater plug(s) or open circuit on the preheating unit return line to the
computer
NOTESPriorities when dealing with a number of faults:
Deal with fault DF017 Preheating control circuit first, if it is present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– when the ignition is switched on, during the preheating phase,
– engine running in postheating phase,
– controlling the heater plugs using command AC037 Preheating relay.
Special notes:
If the fault is present:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
–The European On Board Diagnostic injection warning light is lit.
– Difficult to start the engine.
– Refer to the Wiring Diagram Technical Notes for the vehicle to locate the fuses and
relays concerned.
IMPORTANT
Please observe the cleanliness guidelines and safety advice.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF025/EDC16C36_V4C_DF025/EDC16C36_V48_DF025/EDC16C36_V50_DF025/EDC16C36_V54_DF025/
EDC16C36_V58_DF025
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 74 of 431

13B-74V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF032
PRESENT
OR
STOREDTHERMOPLUNGER 1 RELAY CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– actuator command AC063 Thermoplunger no. 1 relay.
Special notes:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.1
NOTESNone.
1.DEFSpecial note:
This fault appears when the computer control section has
overheated.
Check the conformity of fuses F2 (70A) and F3 (70A) on component 777, replace if necessary.
Check the connections on the additional heater interface unit.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition feed on connections BP27 and BP35 of component 1550.
If there is no + 12 V, refer to the interpretation of fault DF151 Main relay circuit.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EDC16C36_V48_DF032/EDC16C36_V58_DF032
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58

Page 76 of 431

13B-76V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF033
PRESENT
OR
STOREDTHERMOPLUNGER 2 RELAY CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– actuator command AC064 Thermoplunger no. 2 relay.
Special notes:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.1
NOTESNone.
1.DEFSpecial note:
This fault appears when the computer control section has
overheated.
Check the conformity of fuses F2 (70A) and F3 (70A) on component 777, replace if necessary.
Check the connections on the additional heater interface unit.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition feed on connections BP27 and BP35 of component 1550.
If there is no + 12 V, refer to the interpretation of fault DF151 Main relay circuit.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EDC16C36_V48_DF033/EDC16C36_V58_DF033
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58

Page 78 of 431

13B-78V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF034
PRESENT
OR
STOREDTHERMOPLUNGER 3 RELAY CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– actuator command AC031 Thermoplunger no. 3 relay.
Special notes:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.1
NOTESNone.
1.DEFSpecial note:
This fault appears when the computer control section has
overheated.
Check the conformity of fuses F2 (70A) and F3 (70A) on component 777, replace if necessary.
Check the connections on the additional heater interface unit.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition feed on connections BP27 and BP35 of component 1550.
If there is no + 12 V, refer to the interpretation of fault DF151 Main relay circuit.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EDC16C36_V48_DF034/EDC16C36_V58_DF034EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.

Page 209 of 431

13B-209V9 MR-372-J84-13B450$131.mif
DIESEL INJECTION
Fault finding – Interpretation of statuses13B
ET004
CONTINUED
Sensor electrical conformity
YESThe air conditioning authorisation only changes to YES if:
– the air conditioning request has been made by the driver (air conditioning switch in
AC or AUTO position with minimum ventilation),
– the engine is not under full load,
– the air conditioning system is not faulty.
NOStatus ET004 remains NO under the following conditions:
– Vehicle stopped with the ignition on,
– faults present in the air conditioning circuit,
– no air conditioning request made by the driver,
– engine under full load.
If status ET004 remains NO then the air conditioning should be authorised. Check:
– that the air conditioning compressor starts correctly,
– the air conditioning system supply fuses,
– the presence of refrigerant in the air conditioning circuit,
If the fault is still present, check the air conditioning computer faults (see 62B, Air
conditioning).
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 373 of 431

13B-373
AFTER REPAIRRepeat the conformity check in the interpretation of statuses and parameters
V9 MR-372-J84-13B450$170.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
AC038LOW-SPEED FAN ASSEMBLY RELAY
NOTESThere must be no present or stored faults.
Perform this fault finding after an engine cooling fault or air conditioning fault.
Refer to the Wiring Diagram Technical Notes for the vehicle to locate the fuses and
relays concerned.
Ignition on and engine stopped.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
If the low speed fan assembly relay does not operate when command AC038 is run:
Check the low-speed fan assembly relay mounting and the connections of the engine management computer.
Check the fan assembly connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, check that the relay is actuated by the engine management computer as follows:
Disconnect the low-speed fan assembly relay, and fit a 50 to 100 Ω resistor on the relay mounting in place of the
coil, and connect a voltmeter as follows:
– positive terminal to +12 V battery,
– negative terminal to connection 3JN of component 336.
Run command AC038
If the voltmeter shows the battery voltage (4 ON-OFF cycles of 10 seconds), replace the relay.
If the low speed fan assembly relay is supplied using command AC038, but there is still a fan assembly activation
fault, check using the wiring diagram.
The conformity of the fan assembly FM15 maxi-fuse.
EDC16C36_V44_AC038/EDC16C36_V4C_AC038/EDC16C36_V48_AC038/EDC16C36_V50_AC038/EDC16C36_V54_AC038/
EDC16C36_V58_AC038EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58

Page 375 of 431

13B-375
AFTER REPAIRRepeat the conformity check in the interpretation of statuses and parameters
V9 MR-372-J84-13B450$170.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
AC039HIGH SPEED FAN ASSEMBLY
NOTESThere must be no present or stored faults:
Perform this fault finding after an engine cooling fault.
Refer to the Wiring Diagram Technical Notes for the vehicle to locate the fuses and
relays concerned.
Ignition on and engine stopped.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
If, when running command AC039, the high-speed fan assembly relay is not activated:
Check the high-speed fan assembly relay mounting and the connections of the engine management computer.
Check the fan assembly connections.
Repair if necessary.
If the fault is still present, check that the relay is actuated by the engine management computer as follows:
Disconnect the high speed fan assembly relay 335, fit a 50 to 100 Ω resistor on its mounting in place of the coil,
and connect a voltmeter as follows:
- positive terminal to +12 V battery,
- negative terminal to connection 3JP of component 335.
Run command AC039.
If the voltmeter shows the battery voltage (4 ON-OFF cycles of 10 seconds), replace the relay.
Disconnect the high speed fan assembly relay 337, fit a 50 to 100 Ω resistor on its mounting in place of the coil,
and connect a voltmeter as follows:
- positive terminal to +12 V battery,
- negative terminal to connection 3JP of component 337.
Run command AC039.
If the voltmeter shows the battery voltage (4 ON-OFF cycles of 10 seconds), replace the relay.
If the high-speed fan assembly relays are fed using command AC153, but there is still a fan activation fault, check
using the wiring diagram:
The conformity of the fan assembly FM15 maxi-fuse.
EDC16C36_V44_AC039/EDC16C36_V4C_AC039/EDC16C36_V48_AC039/EDC16C36_V50_AC039/EDC16C36_V54_AC039/
EDC16C36_V58_AC039EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58