fuel cap release SKODA OCTAVIA 1997 1.G / (1U) 1.8 92kw Engine Workshop Manual

Page 127 of 136

Downloaded from www.Manualslib.com manuals search engine Fuel Supply System20
Edition 08.96


 
Test procedure
- Switch off ignition.
- Connect remote control V.A.G 1348/3A with
adapter cable V.A.G 1348/3-2 ⇒ page 20-8.
- Remove cap from the fuel filler neck.
Important! Fuel system is pressurised! Place cleaning ragsaround the connection point before opening the
system. Then, release pressure by carefullyloosening the connection point.
- Disconnect fuel return flow pipe -2- (press
release buttons).
- Connect auxiliary hose to adapter V.A.G 1318/17 and fit onto the fuel return flow pipe of the engine and hold in a measuring vessel.
- Operate remote control for 15 seconds (press button and hold).
- Compare quantity of fuel supplied with spe-
cification.
*)Minimum delivery cm3/15 s
**)Voltage at fuel pump when engine switched
off and pump running (about 2 V less than battery voltage).