manual transmission TOYOTA AVENSIS 2005 Service Manual PDF

Page 976 of 5135

D26542
E1
ECT SolenoidECM
17
SLT+ E13 P±L
2 O
16
SLT± E13 P
7 SLT+
SLT± G
D25234
SLT+
SLT±
± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FE))05±895
AVENSIS REPAIR MANUAL (RM1018E)
WIRING DIAGRAM
INSPECTION PROCEDURE
1 INSPECT TRANSMISSION WIRE(SLT)
(a) Disconnect the transmission wire connector from the
transaxle.
(b) Measure the resistance between terminals SLT+ and
SLT± of the transmission wire connector.
OK:
Resistance: 5.0 to 5.6 at 20C (68F)
(c) Measure the resistance between body ground and that
SLT+ as well as SLT± of the transmission wire connector.
OK:
Resistance: 1M or higher
NG Go to step 3
OK

Page 977 of 5135

C95813SLT+
SLT±
D25466
12
12
(+)
(±)
05±896± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FE))
AVENSIS REPAIR MANUAL (RM1018E)
2 CHECK HARNESS AND CONNECTOR(TRANSMISSION WIRE ± ECM)
(a) Connect the transmission wire connector to the transaxle.
(b) Disconnect the ECM connector.
(c) Measure the resistance between terminals SLT+ and
SLT± of the ECM connector.
OK:
Resistance: 5.0 to 5.6  at 20C (68F)
(d) Measure the resistance between body ground and that
SLT+ as well as SLT± of the ECM connector.
OK:
Resistance: 1M or higher
NG REPAIR OR REPLACE HARNESS OR
CONNECTOR
OK
CHECK AND REPLACE ECM
3 INSPECT SHIFT SOLENOID VALVE(SLT)
(a) Remove the shift solenoid valve SLT.
(b) Measure the resistance between terminals of the shift so-
lenoid valve SLT.
OK:
Resistance: 5.0 to 5.6  at 20C (68F)
(c) Connect the positive (+) lead with a 21 W bulb to terminal
2 and the negative (±) lead to terminal 1 of the solenoid
valve connector, then check the movement of the sole-
noid valve.
OK:
The solenoid valve makes an operating noise.
NG REPLACE SHIFT SOLENOID VALVE(SLT)
OK
REPAIR OR REPLACE TRANSMISSION WIRE

Page 983 of 5135

D25234
SL1+
SL1± SL2±SL2+
S4
± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FE))05±889
AVENSIS REPAIR MANUAL (RM1018E)
INSPECTION PROCEDURE
1 INSPECT TRANSMISSION WIRE(SL1/SL2/S4)
(a) Disconnect the transmission wire connector from the
transaxle.
(b) Measure the resistance between terminals SLT1+ and
SL1± of the transmission wire connector.
OK:
Resistance: 5.0 to 5.6  at 20C (68F)
(c) Measure the resistance between body ground and that
SL1+ as well as SL1± of the transmission wire connector.
OK:
Resistance: 1M or higher
NG Go to step 3
(d) Measure the resistance between terminals SL2+ and
SL2±.
OK:
Resistance: 5.1 to 5.5  at 20C (68F)
(e) Measure the resistance between body ground and that
SL2+ as well as SL2± of the transmission wire connector.
OK:
Resistance: 1M or higher
NG Go to step 4
(f) Measure the resistance between terminal S4 of the trans-
mission wire connector and body ground.
OK:
Resistance: 11 to 15  at 20C (68F)
NG Go to step 5
OK

Page 984 of 5135

C95812
E1
S4
SL1±
SL2+ SL1+
SL2±
D25466
12
12
(+)
(±)
05±890± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FE))
AVENSIS REPAIR MANUAL (RM1018E)
2 CHECK HARNESS AND CONNECTOR(TRANSMISSION WIRE ± ECM)
(a) Connect the transmission wire connector to the transaxle.
(b) Disconnect the connector from the ECM.
(c) Measure the resistance between terminals.
OK:
Resistance:
SL1+ ± SL1±: 5.0 to 5.6  at 20C (68F)
SL2+ ± SL2±: 5.1 to 5.5  at 20C (68F)
S4 ± E1: 11 to 15  at 20C (68F)
(d) Measure the resistance between terminals SL1+, SL1±,
SL2+ and SL2± of the ECM connector and body ground.
OK:
Resistance: 1M or higher
NG REPAIR OR REPLACE HARNESS OR
CONNECTOR
OK
CHECK AND REPLACE ECM
3 INSPECT SHIFT SOLENOID VALVE(SL1)
(a) Remove the shift solenoid valve SL1.
(b) Measure the resistance between terminals of the shift so-
lenoid valve SL1.
OK:
Resistance: 5.0 to 5.6  at 20C (68F)
(c) Connect the positive (+) lead with a 21 W bulb to terminal
2 and the negative (±) lead to terminal 1 of the solenoid
valve connector, then check the movement of the sole-
noid valve.
OK:
The solenoid valve makes an operating noise.
NG REPLACE SHIFT SOLENOID VALVE(SL1)
OK
REPAIR OR REPLACE TRANSMISSION WIRE

Page 985 of 5135

D25466
12
12
(+)
(±)
D25467
(+) (±)
± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FE))05±891
AVENSIS REPAIR MANUAL (RM1018E)
4 INSPECT SHIFT SOLENOID VALVE(SL2)
(a) Remove the shift solenoid valve SL2.
(b) Measure the resistance between terminals of the shift so-
lenoid valve SL2.
OK:
Resistance: 5.1 to 5.5  at 20C (68F)
(c) Connect the positive (+) lead with a 21 W bulb to terminal
2 and the negative (±) lead to terminal 1 of the solenoid
valve connector, then check the movement of the sole-
noid valve.
OK:
The solenoid valve makes an operating noise.
NG REPLACE SHIFT SOLENOID VALVE(SL2)
OK
REPAIR OR REPLACE TRANSMISSION WIRE
5 INSPECT SHIFT SOLENOID VALVE(S4)
(a) Remove the shift solenoid valve S4.
(b) Measure the resistance between the solenoid connector
and the solenoid body.
OK:
Resistance: 11 to 15  at 20C (68F)
(c) Connect the positive (+) lead to the terminal of solenoid
connector and the negative (±) lead to the solenoid body.
OK:
The solenoid valve makes an operating noise.
NG REPLACE SHIFT SOLENOID VALVE(S4)
OK
REPAIR OR REPLACE TRANSMISSION WIRE

Page 989 of 5135

D25234
SL1+
SL1± SL2±SL2+
S4
± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FSE))05±959
AVENSIS REPAIR MANUAL (RM1018E)
INSPECTION PROCEDURE
1 INSPECT TRANSMISSION WIRE(SL1/SL2/S4)
(a) Disconnect the transmission wire connector from the
transaxle.
(b) Measure the resistance between terminals 5 and 10.
OK:
Resistance: 5.0 to 5.6  at 20C (68F)
(c) Measure the resistance between terminals 5 and 10 of
the transmission wire connector and body ground.
OK:
Resistance: 1M or higher
NG Go to step 3
(d) Measure the resistance between terminals 4 and 9.
OK:
Resistance: 5.1 to 5.5  at 20C (68F)
(e) Measure the resistance between terminals 4 and 9 of the
transmission wire connector and body ground.
OK:
Resistance: 1M or higher
NG Go to step 4
(f) Measure the resistance between terminal 8 and body
ground.
OK:
Resistance: 11 to 15  at 20C (68F)
NG Go to step 5
OK

Page 990 of 5135

C91565
E1
S4
SL1±
SL2+ SL1+
SL2±
D25466
12
12
(+)
(±)
05±960± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FSE))
AVENSIS REPAIR MANUAL (RM1018E)
2 CHECK HARNESS AND CONNECTOR(TRANSMISSION WIRE ± ECM)
(a) Connect the transmission wire connector to the transaxle.
(b) Disconnect the connector from the ECM.
(c) Measure the resistance between terminals of the ECM
connector.
OK:
Resistance:
SL1+ ± SL1±: 5.0 to 5.6  at 20C (68F)
SL2+ ± SL2±: 5.1 to 5.5  at 20C (68F)
S4 ± E1: 11 to 15  at 20C (68F)
(d) Measure the resistance between terminals SL1+, SL1±,
SL2+ and SL2± of the ECM connector and body ground.
OK:
Resistance: 1M or higher
NG REPAIR OR REPLACE HARNESS OR
CONNECTOR
OK
CHECK AND REPLACE ECM
3 INSPECT SHIFT SOLENOID VALVE(SL1)
(a) Remove the shift solenoid valve SL1.
(b) Measure the resistance between terminals of the shift so-
lenoid valve SL1.
OK:
Resistance: 5.0 to 5.6  at 20C (68F)
(c) Connect the positive (+) lead with a 21 W bulb to terminal
2 and the negative (±) lead to terminal 1 of the solenoid
valve connector, then check the movement of the sole-
noid valve.
OK:
The solenoid valve makes an operating noise.
NG REPLACE SHIFT SOLENOID VALVE(SL1)
OK
REPAIR OR REPLACE TRANSMISSION WIRE

Page 991 of 5135

D25466
12
12
(+)
(±)
D25467
(+) (±)
± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FSE))05±961
AVENSIS REPAIR MANUAL (RM1018E)
4 INSPECT SHIFT SOLENOID VALVE(SL2)
(a) Remove the shift solenoid valve SL2.
(b) Measure the resistance between terminals of the shift so-
lenoid valve SL2.
OK:
Resistance: 5.1 to 5.5  at 20C (68F)
(c) Connect the positive (+) lead with a 21 W bulb to terminal
2 and the negative (±) lead to terminal 1 of the solenoid
valve connector, then check the movement of the sole-
noid valve.
OK:
The solenoid valve makes an operating noise.
NG REPLACE SHIFT SOLENOID VALVE(SL2)
OK
REPAIR OR REPLACE TRANSMISSION WIRE
5 INSPECT SHIFT SOLENOID VALVE(S4)
(a) Remove the shift solenoid valve S4.
(b) Measure the resistance between the solenoid connector
and the solenoid valve body.
OK:
Resistance: 11 to 15  at 20C (68F)
(c) Connect the positive (+) lead to the terminal of solenoid
connector and the negative (±) lead to the solenoid valve
body.
OK:
The solenoid valve makes an operating noise.
NG REPLACE SHIFT SOLENOID VALVE(S4)
OK
REPAIR OR REPLACE TRANSMISSION WIRE

Page 992 of 5135

D25466
12
12
(+)
(±)
05±954± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FSE))
AVENSIS REPAIR MANUAL (RM1018E)
DTC P0746 PRESSURE CONTROL SOLENOID ºAº
PERFORMANCE (SHIFT SOLENOID VALVE
SL1)
SYSTEM DESCRIPTION
The ECM uses signals from the vehicle speed sensor to detect the actual gear position (1st, 2nd, 3rd or O/D
gear).
Then the ECM compares the actual gear with the shift schedule in the ECM memory to detect mechanical
troubles of the shift solenoid valves and valve body.
DTC No.DTC Detecting ConditionTrouble Area
P0746The gear required by the ECM does not match the actual gear
when driving (2±trip detection logic)Shift solenoid valve SL1 is stuck open or closed
Valve body is blocked up or stuck
Automatic transaxle (clutch, brake or gear etc.)
INSPECTION PROCEDURE
1 INSPECT SHIFT SOLENOID VALVE(SL1)
(a) Remove the shift solenoid valve SL1.
(b) Measure the resistance between terminals of the shift so-
lenoid valve SL1.
OK:
Resistance: 5.0 to 5.6  at 20C (68F)
(c) Connect the positive (+) lead with a 21 W bulb to terminal
2 and the negative (±) lead to terminal 1 of the solenoid
valve connector, then check the movement of the sole-
noid valve.
OK:
The solenoid valve makes an operating noise.
NG REPLACE SHIFT SOLENOID VALVE(SL1)
OK
2 INSPECT TRANSMISSION VALVE BODY ASSY
NG REPAIR OR REPLACE TRANSMISSION VALVE
BODY ASSY
OK
05C9D±01

Page 995 of 5135

C54864
DSL
C91565
DSLE1
05±952± DIAGNOSTICSELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] (U241E(1AZ±FSE))
AVENSIS REPAIR MANUAL (RM1018E)
INSPECTION PROCEDURE
1 INSPECT TRANSMISSION WIRE(DSL)
(a) Disconnect the solenoid connector from the transaxle.
(b) Measure the resistance between the terminal 3 and the
body ground.
OK:
Resistance: 11 to 13 at 20C (68F)
NG Go to step 3
OK
2 CHECK HARNESS AND CONNECTOR(TRANSMISSION WIRE ± ECM)
(a) Connect the transmission wire connector.
(b) Disconnect the ECM connector.
(c) Measure the resistance between terminal DSL and E1.
OK:
Resistance: 11 to 13 at 20C (68F)
NG REPAIR OR REPLACE HARNESS OR
CONNECTOR
OK
CHECK AND REPLACE ECM