display TOYOTA PRIUS PLUG-IN HYBRID 2018 Owner's Manual
Page 125 of 772
1252-2. Charging
2
Plug-in hybrid system
PRIUS PHV_OM_OM47C99E_(EE)
The illumination/flashing pattern
changes to inform the user of the
charging status in the following
ways.
*1: If equipped
*2: Flashes for approximately 15 seconds.
*3: Flashes for approximately 10 seconds.
■Charging indicator
When a system malfunction occurs while charging or using the Remote Air
Conditioning System, the charging indicator rapidly flashes for approximately
10 seconds, and then turns off.
If this occurs, the next time the hybrid system is started, a message is dis-
played on the multi-information display. When a message is displayed, follow
the instructions displayed on the screen.
Charging indicator
Illumination/flashing
patternVehicle condition
Illuminated
• Charging is in progress
• Charging is possible
• “Traction Battery Heater” (P. 149) is operating
• “Traction Battery Cooler” (P. 150) is operating
*1
Flashing
(normally)
*2When charge schedule is registered (P. 171) and
charging cable is connected to vehicle
Rapidly flashing*3When charging cannot be carried out due to mal-
function in a power source or the vehicle etc.
(P. 189)
Not illuminated
• Charging connector is not inserted into charging
inlet
• When the charging timer (P. 171) is on standby
• When charging is completed
Page 145 of 772
1452-2. Charging
2
Plug-in hybrid system
PRIUS PHV_OM_OM47C99E_(EE)
■The charging environment
For safe charging, the following charging equipment and settings are recom-
mended.
●Rain-tight socket
When charging outdoors, connect the plug to a rain-tight socket, and ensure
that the plug remains waterproof while the plug is connected.
●Dedicated circuit
• To reduce the risk of fire, connect only to an at least 13A branch circuit
with an over-current protection.
• To reduce the risk of electric shock when working with the plug, connect
to a socket that has a Residual Current Circuit-Breaker (RCCB) installed.
●Remote switch
Allows the electricity from the socket to be interrupted by operating a switch,
thus allowing safe removal and insertion of the plug on rainy days.
■When your circuit breaker trips during charging
The upper limit of the charging current can be changed in the “Vehicle Set-
tings” settings on the multi-information display.
Press or of the meter control switches to select (“Vehicle
Settings”) in the screen, and then press .
Press or of the meter control switches to select “Charge Settings”,
and then press .
The “Charge Settings” screen will display.
Press or of the meter control switches to select “Charge Settings”,
and then press .
The “Charge Current” screen will display.
Press or of the meter control switches to select “8A”, and then
press .
The maximum charging current during charging will be restricted to 8A.
*
If the breaker still trips while charging, even after changing the upper limit of
the charging current, check if the connected power source meets the speci-
fied charging conditions. (P. 144)
*: Restricting the charging current will lengthen the charging time.
1
2
3
4
Page 150 of 772
1502-2. Charging
PRIUS PHV_OM_OM47C99E_(EE)■
“Traction Battery Cooler” (if equipped)
When the hybrid battery (traction battery) is hot, this function pro-
tects it by using the vehicle air conditioning to cool it before
charging is carried out.
When the hybrid battery (trac-
tion battery) is above a certain
temperature and the power
switch is turned off, a check
screen is displayed on the
multi-information display that
indicates whether “Traction Bat-
tery Cooler” is implemented.
When “No” is selected, the hybrid battery (traction battery) cooling sys-
tem does not operate.
■“Traction Battery Heater”
●“Traction Battery Heater” may operate when charging is not being per-
formed.
●When “Traction Battery Heater” is operating, the charging indicator illumi-
nates.
●When “Traction Battery Heater” is operating during charging, the charging
time may be longer than normal.
●If the outside temperature becomes high while “Traction Battery Heater” is
operating, charging may complete earlier than the “Departure” time set.
(P. 171)
●“Traction Battery Heater” can be turned on and off in the “Vehicle Settings”
settings on the multi-information display. (P. 738)
Page 151 of 772
1512-2. Charging
2
Plug-in hybrid system
PRIUS PHV_OM_OM47C99E_(EE)■“Traction Battery Cooler” (if equipped)
●When the hybrid battery (traction battery) is above a certain temperature
and the power switch is turned off, a check screen is displayed on the multi-
information display that indicates whether “Traction Battery Cooler” is imple-
mented. Approximately 5 minutes after selecting “Yes” on this screen, sys-
tem operation becomes possible.
●When charging starts, “Traction Battery Cooler” only operates if the hybrid
battery (traction battery) temperature is hot.
●The charging indicator is illuminated while “Traction Battery Cooler” is on
standby or operating.
●“Traction Battery Cooler” is implemented for a maximum of approximately
30 minutes. However, when the “Departure” time is set (P. 171) and there
is not sufficient time between the current time and the time that charging will
complete, “Traction Battery Cooler” operation time may become shorter.
●When there is a small amount of remaining charge in the hybrid battery
(traction battery), even if the hybrid battery (traction battery) is hot, “Traction
Battery Cooler” may not be implemented.
●When the following operations are performed while “Traction Battery Cooler”
is operating, the hybrid battery (traction battery) cooling operation stops.
• A door is opened
• The hood is opened
• The power switch is turned to any mode other than off
• The alarm operates (if equipped) (P. 8 8 )
• The shift position is changed to any position other than P
• The Remote Air Conditioning System is operated (P. 542)
• “Charge Now” is implemented (P. 179)
• The amount of remaining charge in the hybrid battery (traction battery) is
below a certain amount
●When the power switch is turned off, a check screen is displayed on the
multi-information display that indicates whether “Traction Battery Cooler” is
implemented. This check screen can be turned on and off in the “Meter Cus-
tomize” settings on the multi-information display (P. 253). However, when
the check screen is set to “Off”, “Traction Battery Cooler” is no longer oper-
ates.
●“Traction Battery Cooler” uses the power of the hybrid battery (traction bat-
tery) and external power source.
• While “Traction Battery Cooler” is operating, the amount of the remaining
charge of the hybrid battery (traction battery) increases and decreases in
a certain range, and does not increase as in normal charging.
• The operation of “Traction Battery Cooler” is recognized as charging by a
charging equipment. The charging equipment that calculates the fee
according to charging time causes a charging fee.
Page 154 of 772
1542-2. Charging
PRIUS PHV_OM_OM47C99E_(EE)
Information related to charging can be displayed and checked on the
vehicle’s multi-information display.
■While charging
When any door is opened
during charging, the current
charging condition and remain-
ing time until charging is com-
plete can be checked.
■After charging is complete
After charging is complete, the
first time that the hybrid system
is started, a message detailing
the results of the charging is
displayed. Also, a message is
displayed if an operation that
cannot be performed or a situa-
tion that charging cannot be
performed occurs during
charging is performed.
When a message is displayed, follow the instructions displayed on the
screen. (P. 192)
■Combination meter display during charging
If approximately 100 seconds elapse after the power switch is turned to ON
mode during charging, the power switch will automatically turn off and the dis-
play will disappear.
Checking information related to charging
Page 157 of 772
1572-2. Charging
2
Plug-in hybrid system
PRIUS PHV_OM_OM47C99E_(EE)■Capacity reduction of the hybrid battery (traction battery)
The capacity of the hybrid battery (traction battery) will decline gradually
when the hybrid battery (traction battery) is in use. The rate at which it
declines will differ in accordance with environmental conditions and the way
in which the vehicle is used. Observing the following can help suppress bat-
tery capacity decline.
●Avoid parking the vehicle in areas with a high temperature under direct sun-
light when the hybrid battery (traction battery) is fully charged.
●Avoid accelerating and decelerating frequently and suddenly when EV driv-
ing.
●Avoid frequent driving near the top speed for EV driving. (P. 1 0 6 )
●Leave a low level of charge in the hybrid battery (traction battery) when
leaving the vehicle undriven for a long period of time.
After confirming that EV mode has switched to HV mode, turn the power
switch off.
●Use the charging timer function as much as possible in order to fully charge
the hybrid battery (traction battery) immediately before starting off.
(P. 171)
Also, if the hybrid battery (traction battery) capacity reduces, the distance that
can be driven in EV mode decreases. However, vehicle performance does
not significantly become worse.
■When the remaining charge of the hybrid battery (traction battery) is low
after charging
In the following situations, the remaining charge of the hybrid battery (traction
battery) after charging completes may be less than normal in order to protect
the system (the EV driving range after the battery is fully charged may be
shorter).
*
●Charging is carried out when the outside temperature is low or high
●Charging is carried out immediately after high-load driving or in extreme
heat
When none of the above situations apply and there is a drastic drop in the
remaining charge of the hybrid battery (traction battery) after charging com-
pletes, have the vehicle inspected by any authorized Toyota retailer or Toyota
authorized repairer, or any reliable repairer.
*: When this occurs, even if the remaining charge display of the hybrid battery
(traction battery) shows that it is fully charged, the remaining charge rapidly
decreases faster than normal.
Page 161 of 772
1612-2. Charging
2
Plug-in hybrid system
PRIUS PHV_OM_OM47C99E_(EE)
When using the Mode 3
charging cable (if equipped):
Remove the cap of the charging
connector that is connected to
the charging equipment, and
then connect the charging con-
nector to the charging equip-
ment.
Follow the instructions displayed on the charging equipment for details
regarding how to connect the charging cable and how to start charging.
Depending on the charging device, it may be necessary to receive authori-
zation to use the device. For details, refer to the information displayed on
the charging device.
Open the charging port lid.
( P. 122)
The charging inlet light will illumi-
nate.
Remove the charging inlet cap
and secure it as shown in the
illustration.
Charging inlet light3
4
Page 163 of 772
1632-2. Charging
2
Plug-in hybrid system
PRIUS PHV_OM_OM47C99E_(EE)
If the charging indicator flashes
after inserting the charging con-
nector:
The charge schedule is regis-
tered (P. 171). Carry an elec-
tronic key and press the
charging connector lock switch
to unlock the charging connec-
tor.
After temporarily removing the charging connector, reinsert it within
approximately 5 seconds. (P. 163)
If the error warning indicator on the CCID (Charging Circuit Interrupting
Device) flashes during charging, check P. 129 and follow the correction
procedure.
The charging indicator will turn off when charging is completed.
■During charging
●The surface of the CCID (Charging Circuit Interrupting Device) may become
hot, but this does not indicate a malfunction. (When using Mode 2 charging
cable.)
●Depending on radio wave conditions, interference may be heard on the
radio.
●The current charging condition and the estimated time until charging will
complete can be checked on the multi-information display. (P. 154)
●During charging, the hybrid battery (traction battery) status indicator illumi-
nates and flashes, and changes according to the charging amount.
(P. 123)
■If the charging indicator flashes after connecting the charging cable
The charge schedule (P. 171) is registered and charging cannot be per-
formed immediately. To cancel charging using the timer and start charging
immediately, perform any of the following procedures.
●Turn “Charge Now” on (P. 179)
●While the charging indicator is flashing, remove and reconnect the charging
connector within 5 seconds
■When the charging connector cannot be inserted into the charging inlet
P. 141
Page 166 of 772
1662-2. Charging
PRIUS PHV_OM_OM47C99E_(EE)
■Charging time
P. 148
■ Safety function
Charging will not start when the charging connector is not locked. If the
charging indicator does not illuminate even when the charging connector is
inserted, remove and reinsert the connector, and then check that the charging
indicator illuminates.
■ When the outside temperature is low or high
The level shown on the remaining charge display ( P. 235) may drop slightly
when the power switch is turned to ON mode, even if charging has been com-
pleted and the hybrid battery (traction battery) is fully charged. However, this
does not indicate a malfunction.
■ Charging time may increase
P. 149
■ While charging
When the power switch is turned to ON mode and the energy monitor dis-
plays, the charging connector is displayed on the energy monitor and the flow
of electricity during charging is displayed ( P. 226). Also, when the charging
connector is locked, is displayed.
■ When removing the charging connector
■ Push lifter
Carry an electronic key and press the
charging connector lock switch and check
that the lock is released, and then pull the
charging connector towards you.
When the charging port lid is open, make
sure not to touch the push lifter. If it is
touched accidentally, the charging port lid
or connector lock may operate.
If they are accidentally operated, carry an
electronic key or unlock the doors, and
then press the charging connector lock
switch to unlock.Push lifter
Page 174 of 772
1742-2. Charging
PRIUS PHV_OM_OM47C99E_(EE)
When operating timer settings, use the charging timer switch and
meter control switches.
Charging timer switch
Meter control switches
(P. 199)
Multi-information display
■Registering the charge schedule
Press the charging timer switch.
The “Charge Schedule” screen will display on the multi-information dis-
play.
Press or of the
meter control switches to
select “Scheduled Events”,
and then press .
The “Scheduled Events” screen
will display.
Press or of the
meter control switches to
select “+”, and then press
.
The “Edit Charging Event”
screen will display.
Setting procedure
1
2
3
1
2
3