ECO mode CHRYSLER VOYAGER 2004 Manual Online

CHRYSLER VOYAGER 2004 Manual Online VOYAGER 2004 CHRYSLER CHRYSLER https://www.carmanualsonline.info/img/25/56870/w960_56870-0.png CHRYSLER VOYAGER 2004 Manual Online

Page 2431 of 2585

CHRYSLER VOYAGER 2004 Manual Online actuator cannot be adjusted or repaired and, if dam-
aged or faulty, it must be replaced.
REMOVAL
(1) Disconnect and isolate the battery negative
cable.
(2) Remove the right quarter trim panel and rig

Page 2433 of 2585

CHRYSLER VOYAGER 2004 Manual Online Refer to the appropriate wiring information for
diagnosis and testing of the micro-relay and for com-
plete HVAC wiring diagrams.
REMOVAL
(1) Disconnect and isolate the battery negative
cable.
(2) Unl

Page 2434 of 2585

CHRYSLER VOYAGER 2004 Manual Online (1) Disconnect and isolate the battery negative
cable.
(2) Disconnect the rear HVAC wire harness con-
nector from the rear blower motor resistor.
(3) Check for continuity between each of the
blower mo

Page 2435 of 2585

CHRYSLER VOYAGER 2004 Manual Online OPERATION
The rear mode door actuator is connected to the
front heater-A/C control module through the vehicle
electrical system by a dedicated two-wire take out
and connector of the rear HVAC wire har

Page 2436 of 2585

CHRYSLER VOYAGER 2004 Manual Online (6) Install the screw that secures the front of the
rear HVAC housing to the right quarter inner panel.
Tighten the screw to 11 N´m (97 in. lbs.).
(7) Install the screw that secures the back of the
r

Page 2441 of 2585

CHRYSLER VOYAGER 2004 Manual Online (2) Engage the retainer features on the top of the
outlet housing with their receptacles at the top of the
center bezel, then roll the bottom of the outlet hous-
ing downwards towards the center bezel

Page 2446 of 2585

CHRYSLER VOYAGER 2004 Manual Online (3) Align the locator hole on the center floor distri-
bution duct with the weld stud on the front floor
panel.
(4) Using hand pressure, push the locator hole of
the center floor distribution duct dow

Page 2449 of 2585

CHRYSLER VOYAGER 2004 Manual Online housing half to the lower half. Tighten the screws to
2 N´m (17 in. lbs.).
(3) Position the upper air inlet housing onto the
top of the HVAC housing over the recirculation air
door and the blower mot

Page 2462 of 2585

CHRYSLER VOYAGER 2004 Manual Online present. If system will not maintain vacuum level,
proceed with this procedure.
(2) Prepare a 0.284 Kg. (10 oz.) refrigerant charge
to be injected into the system.
(3) Connect and dispense 0.284 Kg. (

Page 2464 of 2585

CHRYSLER VOYAGER 2004 Manual Online NOTE: The proper amount of R-134a refrigerant for
the refrigerant system in this model is:
²Single or Dual Zone (Front Unit Only - 2.5L Die-
sel) ± 0.91 kilograms (2.00 pounds or 32 ounces)
²Single