fuel DACIA DUSTER 2009 1.G Heating And Air Conditioning Workshop Manual
[x] Cancel search | Manufacturer: DACIA, Model Year: 2009, Model line: DUSTER, Model: DACIA DUSTER 2009 1.GPages: 54, PDF Size: 1.16 MB
Page 19 of 54
Downloaded from www.Manualslib.com manuals search engine 61A-17
HEATING
Distribution unit: Removal - Refitting
61A
REMOVAL
I - REMOVAL PREPARATION OPERATION
aLock the airbag computer (see Fault finding - Re-
placement of components) (88C, Airbags and pre-
tensioners).
aDisconnect the battery (see Battery: Removal - Re-
fitting) (80A, Battery).
a
aDrain the coolant circuit using the refrigerant
charging station (see Refrigerant circuit: Drain-
ing - Filling) .
aMove aside the engine compartment bulkhead
soundproofing.aRemove the bolts (1) from the pipe unions on the ex-
pansion valve.
aDisconnect the expansion valve pipes.
aFit plugs into the openings.
aFit hose clamps (Ms. 583) at (2) .
aRemove the clips (3) from the heater hoses.
aDisconnect the heater hoses. Special tooling required
Ms. 583Pipe clamps .
Equipment required
refrigerant charging station
AIR CONDITIONING
IMPORTANT
Consult the safety and cleanliness advice and
operation recommendations before carrying out
any repair (see Air conditioning: Precautions
for the repair) .
Note:
Use blanking plugs for the fuel circuits with part
numbers 77 01 208 229 or 77 01 476 857 to plug
any openings exposed to the open air. They m ust
be clean. Do not use any which have already
been used to plug a fuel circuit.
108112
WARNING
In order to avoid any refrigerant leaks, do not
damage (deform, twist, etc.) the pipe.
WARNING
To prevent moisture from entering the system,
place plugs on the cold loop components which
are open to the air.
108111
Page 41 of 54
Downloaded from www.Manualslib.com manuals search engine 62A-10
AIR CONDITIONING
Condenser: Removal - Refitting
AIR CONDITIONING
62A
Location and specifications (tightening torques, parts
always to be replaced, etc.) (see 62A, Air condition-
ing, Air conditioning: List and location of compo-
nents, page 62A-1) .
REMOVAL
I - REMOVAL PREPARATION OPERATION
aPosition the vehicle on a two-post lift (see Vehicle:
Towing and lifting) (02A, Lifting equipment).
aDrain the coolant circuit using the refrigerant
charging station.
aDisconnect the battery (see Battery: Removal - Re-
fitting) (80A, Battery).
aRemove the front bumper (see Front bumper as-
sembly: Exploded view) and (see Exterior body
front trim assembly: Exploded view) (55A, Exteri-
or protection).aRemove:
-the air deflector mountings (1) ,
-the air deflector (2) .
aRemove the intercooler (see ) (12B, Turbocharging).
II - REMOVAL OPERATION
aRemove the bolts from the pipes on the condenser
(see 62A, Air conditioning, Air conditioning: List
and location of components, page 62A-1) .
aDisconnect the pipes from the condenser (see 62A,
Air conditioning, Air conditioning: List and loca-
tion of components, page 62A-1) .
aFit blanking plugs on the pipe openings.
aRemove (see 62A, Air conditioning, Air conditio-
ning: List and location of components, page
62A-1) :
-the condenser bolts,
-the condenser. Equipment required
refrigerant charging station
IMPORTANT
To avoid all risk of damage to the systems, apply
the safety and cleanliness instructions and opera-
tion recommendations before carrying out any
repair (see Air conditioning: Precautions for the
repair) .
WARNING
To prevent moisture from entering the system,
place plugs on the cold loop components which are
open to the air.
Note:
Use blanking plugs for the fuel circuits with part
numbers 77 01 208 229 or 77 01 476 857 to plug
any openings exposed to the open air. They must
be clean. Do not use any which have already been
used to plug a fuel circuit.
WARNING
Consult the device's operating manual to avoid
incorrect use.
145079
K9K
WARNING
In order to avoid any refrigerant leaks, do not
damage (deform, twist, etc.) the pipe.
Page 43 of 54
Downloaded from www.Manualslib.com manuals search engine 62A-12
AIR CONDITIONING
Compressor: Removal - Refitting
AIR CONDITIONING
62A
REMOVAL
I - REMOVAL PREPARATION OPERATION
aPosition the vehicle on a two-post lift (see Vehicle:
Towing and lifting) (02A, Lifting equipment).
aDrain the coolant circuit using the refrigerant
charging station (see Refrigerant circuit: Drain-
ing - Filling) .
aDisconnect the battery (see Battery: Removal - Re-
fitting) (80A, Battery).aRemove:
-the front bumper (see Front bumper: Removal -
Refitting) and (see Exterior body front trim as-
sembly: Exploded view) (55A, Exterior protec-
tion),
-the front right-hand wheel (see Wheel: Removal -
Refitting) (35A, Wheels and tyres),
-the accessories belt (see Accessories belt: Re-
moval - Refitting) (11A, Top and front of engine).
II - REMOVAL OPERATION
aRemove:
-the pipe retaining bracket bolt (1) on the compres-
sor,
-the pipe union bolts (2) on the compressor. Equipment required
refrigerant charging station
Tightening torquesm
compressor bolts21 N.m
pipe union bolts8 N.m
pipe retaining bracket
bolt on the compressor21 N.m
IMPORTANT
Consult the safety instructions and cleanliness
advice and the operation recommendations before
carrying out any repairs (see Air conditioning:
Precautions for repair).
WARNING
To prevent moisture from entering the system,
place plugs on the cold loop components which are
open to the air.
Note:
Use blanking plugs for the fuel circuits with part
numbers 77 01 208 229 or 77 01 476 857 to plug
any openings exposed to the open air. They must
be clean. Do not use any which have already been
used to plug a fuel circuit.
WARNING
Consult the device's operating manual to avoid
incorrect use.
K4M
145190
Page 47 of 54
Downloaded from www.Manualslib.com manuals search engine 62A-16
AIR CONDITIONING
Expansion valve: Removal - Refitting
AIR CONDITIONING
62A
Location and specifications (tightening torques, parts
always to be replaced, etc.) (see 62A, Air condition-
ing, Air conditioning: List and location of compo-
nents, page 62A-1) .
REMOVAL
I - REMOVAL PREPARATION OPERATION
a
aDrain the coolant circuit using the refrigerant
charging station (see Refrigerant circuit: Drain-
ing - Filling) .
aDisconnect the battery (see Battery: Removal - Re-
fitting) (80A, Battery).
aRemove the engine cover.aMove aside the bulkhead soundproofing.
II - REMOVAL OPERATION
aRemove the bolts from the pipes on the expansion
valve (see 62A, Air conditioning, Air condition-
ing: List and location of components, page 62A-
1) .
aDisconnect the pipes from the expansion valve (see
62A, Air conditioning, Air conditioning: List and
location of components, page 62A-1) .
aFit blanking plugs on the pipe openings.
aRemove (see 62A, Air conditioning, Air conditio-
ning: List and location of components, page
62A-1) :
-the expansion valve bolts,
-the expansion valve.
REFITTING
I - REFITTING PREPARATION OPERATION
a
aCheck, and if necessary replace, the refrigerant cir-
cuit pipe seal. Equipment required
refrigerant charging station
IMPORTANT
Consult the safety instructions and cleanliness
advice and the operation recommendations before
carrying out any repairs (see Air conditioning:
Precautions for repair).
WARNING
To prevent moisture from entering the system,
place plugs on the cold loop components which are
open to the air.
Note:
Use blanking plugs for the fuel circuits with part
numbers 77 01 208 229 or 77 01 476 857 to plug
any openings exposed to the open air. They must
be clean. Do not use any which have already been
used to plug a fuel circuit.
WARNING
Consult the device's operating manual to avoid
incorrect use.
K9K
WARNING
In order to avoid any refrigerant leaks, do not
damage (deform, twist, etc.) the pipe.
WARNING
Do not remove the blanking plugs from each
component until the last moment.
Also, do not remove the components from their
packaging until they are to be fitted to the vehi-
cle.
Page 49 of 54
Downloaded from www.Manualslib.com manuals search engine 62A-18
AIR CONDITIONING
Refrigerant pipe seal: Removal - Refitting
62A
REMOVAL
I - REMOVAL PREPARATION OPERATION
a
aDrain the refrigerant circuit using the refrigerant
charging station (see Refrigerant circuit: Drain-
ing - Filling) .
aDisconnect the battery (see Battery: Removal - Re-
fitting) (80A, Battery).
aRemove the connecting pipe concerned:
- (see Condenser - evaporator connecting pipe:
Removal - Refitting) ,
- (see Condenser - expansion valve connecting
pipe: Removal - Refitting) ,
- (see Rear condenser - front condenser con-
necting pipe: Removal - Refitting) ,
- (see Evaporator - dehydrator reservoir con-
necting pipe: Removal - Refitting) ,
- (see Compressor - rear condenser connecting
pipe: Removal - Refitting) ,
- (see Condenser - evaporator connecting pipe:
Removal - Refitting) ,
- (see Compressor - dehydrator reservoir con-
necting pipe: Removal - Refitting) ,
- (see Dehydrator reservoir - rear expansion
valve connecting pipe: Removal - Refitting) ,
- (see Main expansion valve - additional expan-
sion valve pipe: Removal - Refitting) ,
- (see Expansion valve - intermediate pipe con-
necting pipe at the expansion valve outlet: Re-
moval - Refitting) ,
- (see Dehydrator reservoir - expansion valve
connecting pipe: Removal - Refitting) ,
- (see Condenser - dehydrator reservoir con-
necting pipe: Removal - Refitting) ,
- (see Expansion valve - compressor connecting
pipe: Removal - Refitting) ,
- (see Expansion valve - rear expansion valve
connecting pipe: Removal - Refitting) ,
- (see Rear expansion valve - compressor con-
necting pipe: Removal - Refitting) ,
- (see Compressor - condenser connecting pipe:
Removal - Refitting) , Special tooling required
Car. 1363Set of tr im removal levers.
Equipment required
refrigerant charging station
compressed air nozzle
IMPORTANT
To avoid all risk of damage to the systems, apply
the safety and cleanliness instructions and opera-
tion recommendations before carrying out any
repair:
- (see Air conditioning: Precautions for the
repair) ,
- (see Vehicle: Precautions for the repair) (01D,
Mechanical introduction).
WARNING
To prevent moisture from entering the system,
place plugs on the cold loop components which are
open to the air.
WARNING
Do not remove the blanking plugs from each com-
ponent until the last moment.
Also, do not remove the components from their
packaging until they are to be fitted to the vehicle.
Note:
Use blanking plugs for the fuel circuits with part
numbers 77 01 208 229 or 77 01 476 857 to plug
any openings exposed to the open air. They must
be clean. Do not use any which have already been
used to plug a fuel circuit.
WARNING
Consult the device's operating manual to avoid
incorrect use.
Page 52 of 54
Downloaded from www.Manualslib.com manuals search engine 62A-21
AIR CONDITIONING
Refrigerant circuit pipe: Removal - Refitting
AIR CONDITIONING
62A
Location and specifications (tightening torques, parts
always to be replaced, etc.) (see 62A, Air condition-
ing, Air conditioning: List and location of compo-
nents, page 62A-1) .
REMOVAL
I - REMOVAL PREPARATION OPERATION
a
Drain the coolant circuit using the refrigerant
charging station (see Refrigerant circuit: Drain-
ing - Filling) .
aDisconnect the battery (see Battery: Removal - Re-
fitting) (80A, Battery).
For the pipe between the expansion valve and the
condenser:
aPosition the vehicle on a two-post lift (see Vehicle:
Towing and lifting) (02A, Lifting equipment).aRemove:
-the front bumper (see Exterior body front trim as-
sembly: Exploded view) and (see Exterior body
front trim assembly: Exploded view) (55A, Exte-
rior protection),
-the air deflector mountings (1) ,
-the air deflector (2) .
For the pipes connected to the expansion valve:
aRemove the front engine cover.
aMove aside the bulkhead soundproofing.
II - REMOVAL OPERATION
a
aRemove the refrigerant circuit pipe (see 62A, Air
conditioning, Air conditioning: List and location
of components, page 62A-1) .
aFit blanking plugs on the pipe openings. Equipment required
refrigerant charging station
IMPORTANT
Consult the safety instructions and cleanliness
advice and the operation recommendations before
carrying out any repairs (see Air conditioning:
Precautions for repair).
WARNING
To prevent moisture from entering the system,
place plugs on the cold loop components which are
open to the air.
Note:
Use blanking plugs for the fuel circuits with part
numbers 77 01 208 229 or 77 01 476 857 to plug
any openings exposed to the open air. They must
be clean. Do not use any which have already been
used to plug a fuel circuit.
WARNING
Consult the device's operating manual to avoid
incorrect use.
145079
K9K
WARNING
In order to avoid any refrigerant leaks, do not
damage (deform, twist, etc.) the pipe.