ECU DODGE RAM SRT-10 2006 Service Repair Manual
[x] Cancel search | Manufacturer: DODGE, Model Year: 2006, Model line: RAM SRT-10, Model: DODGE RAM SRT-10 2006Pages: 5267, PDF Size: 68.7 MB
Page 4930 of 5267

For a complete wiring diagramRefer to Section 8W.
Theory of Operation
The A/C Heater Control drives the Driver Blend Door Actuator via the (C61) Blend Door Driver circuit and the (C34)
Common Door Driver circuit. The A/C Heater Control drives the Passenger Blend Door Actuator via the (C33) Pas-
senger Blend Door Driver circuit and the (C34) Common Door Driver circuit.The A/C Heater Control drives the
Mode Door 1 (Panel to Floor) Actuator via the (C29) Mode Door 1 Driver circuit and the (C34) Common Door Driver
circuit. The A/C Heater Control drives the Mode Door 2 (Defrost to Floor) Actuator via the (C801) Mode Door 2
Driver circuit and the (C34) Common Door Driver circuit. The A/C Heater Control drives the Recirculation Door
Actuator via the (C32) Recirculation Door Driver circuit and the (C34) Common Door Driver circuit. All of the door
actuators share the (C34) Common Door Driver circuit. Inside the A/C Heater Control, each door actuator has its
own unique driver, but all share a single common door driver circuit. Due tothesharedcircuitrysimilarDTCscan
set at the same time for multiple actuators depending upon the type of short, its location, and the direction the
actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C34) Common Door Driver circuit is shorted to ground.
Possible Causes
(C34) COMMON DOOR DRIVER CIRCUIT SHORTED TO GROUND
(C34) COMMON DOOR DRIVER CIRCUIT SHORTED TO OTHER DOOR DRIVER CIRCUIT(S)
DRIVER BLEND DOOR ACTUATOR
PASSENGER BLEND DOOR ACTUATOR
MODE DOOR 1 (PANEL TO FLOOR) ACTUATOR
MODE DOOR 2 (DEFROST TO FLOOR) ACTUATOR
RECIRCULATION DOOR ACTUATOR
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C34) COMMON DOOR DRIVER CIRCUIT FOR A SHORT TO GROUND
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Measure the resistance of the (C34) Common Door Driver circuit
between ground and the A/C Heater Control C1 harness connector.
Istheresistancebelow10kohms?
Ye s>>
Repair the (C34) Common Door Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
Page 4938 of 5267

For a complete wiring diagramRefer to Section 8W.
Theory of Operation
The A/C Heater Control drives the Blend Door Actuator via the (C61) Blend Door Driver circuit and the (C34) Com-
mon Door Driver circuit. The A/C Heater Control drives the Mode Door 1 (Panel to Floor) Actuator via the (C29)
Mode Door 1 Driver circuit and the (C34)CommonDoorDrivercircuit.TheA/CHeater Control drives the Mode
Door 2 (Defrost to Floor) Actuator via the (C801) Mode Door 2 Driver circuitand the (C34) Common Door Driver
circuit. The A/C Heater Control drives the Recirculation Door Actuator via the (C32) Recirculation Door Driver circuit
and the (C34) Common Door Driver circuit. All of the door actuators share the (C34) Common Door Driver circuit.
Inside the A/C Heater Control, each door actuator has its own unique driver, but all share a single common door
driver circuit. Due to the shared circuitry similar DTCs can set at the sametime for multiple actuators depending
upon the type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C34) Common Door Driver circuit is shorted to ground.
Possible Causes
(C34) COMMON DOOR DRIVER CIRCUIT SHORTED TO GROUND
(C34) COMMON DOOR DRIVER CIRCUIT SHORTED TO OTHER DOOR DRIVER CIRCUIT(S)
BLEND DOOR ACTUATOR
MODE DOOR 1 (PANEL TO FLOOR) ACTUATOR
MODE DOOR 2 (DEFROST TO FLOOR) ACTUATOR
RECIRCULATION DOOR ACTUATOR
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C34) COMMON DOOR DRIVER CIRCUIT FOR A SHORT TO GROUND
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Measure the resistance of the (C34) Common Door Driver circuit
between ground and the A/C Heater Control C1 harness connector.
Istheresistancebelow10kohms?
Ye s>>
Repair the (C34) Common Door Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
Page 4957 of 5267

Theory of Operation
The A/C Heater Control drives the Mode Door 1 (Panel to Floor) Actuator via the (C29) Mode Door 1 Driver circuit
and the (C34) Common Door Driver circuit. All of the door actuators share the (C34) Common Door Driver circuit.
Inside the A/C Heater Control, each door actuator has its own unique driver, but all share a single common door
driver circuit. Due to the shared circuitry similar DTCs can set at the sametime for multiple actuators depending
upon the type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C29) Mode Door 1 Driver circuit is shorted to ground.
Possible Causes
(C29) MODE DOOR 1 DRIVER CIRCUIT SHORTED TO GROUND
(C29) MODE DOOR 1 DRIVER CIRCUIT SHORTED TO OTHER DOOR DRIVER CIRCUIT(S)
MODE DOOR 1 (PANEL TO FLOOR) ACTUATOR
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C29) MODE DOOR 1 DRIVER CIRCUIT FOR A SHORT TO GROUND
NOTE: If present, diagnose and repair DTC B10AB Right Blend
Door Control Circuit High or B10AA Right Blend Door Control Cir-
cuit Low before proceeding.
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Measure the resistance of the (C29) Mode Door 1 Driver circuit
between ground and the A/C Heater Control C1 harness connector.
Istheresistancebelow10kohms?
Ye s>>
Repair the (C29) Mode Door 1 Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
Page 4961 of 5267

Theory of Operation
The A/C Heater Control drives the Mode Door 1 (Panel to Floor) Actuator via the (C29) Mode Door 1 Driver circuit
and the (C34) Common Door Driver circuit. All of the door actuators share the (C34) Common Door Driver circuit.
Inside the A/C Heater Control, each door actuator has its own unique driver, but all share a single common door
driver circuit. Due to the shared circuitry similar DTCs can set at the sametime for multiple actuators depending
upon the type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C29) Mode Door 1 Driver circuit is shorted to ground.
Possible Causes
(C29) MODE DOOR 1 DRIVER CIRCUIT SHORTED TO GROUND
(C29) MODE DOOR 1 DRIVER CIRCUIT SHORTED TO OTHER DOOR DRIVER CIRCUIT(S)
MODE DOOR 1 (PANEL TO FLOOR) ACTUATOR
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C29) MODE DOOR 1 DRIVER CIRCUIT FOR A SHORT TO GROUND
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Measure the resistance of the (C29) Mode Door 1 Driver circuit
between ground and the A/C Heater Control C1 harness connector.
Istheresistancebelow10kohms?
Ye s>>
Repair the (C29) Mode Door 1 Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
Page 4965 of 5267

Theory of Operation
The A/C Heater Control drives the Mode Door 1 (Panel to Floor) Actuator via the (C29) Mode Door 1 Driver circuit
and the (C34) Common Door Driver circuit. All of the door actuators share the (C34) Common Door Driver circuit.
Inside the A/C Heater Control, each door actuator has its own unique driver, but all share a single common door
driver circuit. Note that due to the shared circuitry similar DTCs can set at the same time for multiple actuators
depending upon the type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C29) Mode Door 1 Driver circuit is shorted to voltage.
Possible Causes
(C29) MODE DOOR 1 DRIVER CIRCUIT SHORTED TO VOLTAGE
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C29) MODE DOOR 1 DRIVER CIRCUIT FOR A SHORT TO VOLTAGE
NOTE: If present, diagnose and repair DTC B10AB Right Blend
Door Control Circuit High or B10AA Right Blend Door Control Cir-
cuit Low before proceeding.
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
Measure the voltage of the (C29) Mode Door 1 Driver circuit.
Is the voltage above 0.2 volts?
Ye s>>
Repair the (C29) Mode Door 1 Driver circuit for a short to
voltage.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
2.RUN THE ACTUATOR DTC DETECTION TEST
Turn the ignition off.
Reconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
With the scan tool in HVAC, select System Tests and then select Actuator DTCDetection. When the test is com-
plete, select View DTCs.
Does the scan tool only display: B1042–PANEL MODE DOOR 1 CONTROL CIRCUIT HIGH?
Ye s>>
Replace the A/C Heater Control in accordance with the Service Information.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).
No, Other DTC(s) Displayed
Page 4968 of 5267

Theory of Operation
The A/C Heater Control drives the Mode Door 1 (Panel to Floor) Actuator via the (C29) Mode Door 1 Driver circuit
and the (C34) Common Door Driver circuit. All of the door actuators share the (C34) Common Door Driver circuit.
Inside the A/C Heater Control, each door actuator has its own unique driver, but all share a single common door
driver circuit. Note that due to the shared circuitry similar DTCs can set at the same time for multiple actuators
depending upon the type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C29) Mode Door 1 Driver circuit is shorted to voltage.
Possible Causes
(C29) MODE DOOR 1 DRIVER CIRCUIT SHORTED TO VOLTAGE
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C29) MODE DOOR 1 DRIVER CIRCUIT FOR A SHORT TO VOLTAGE
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
Measure the voltage of the (C29) Mode Door 1 Driver circuit.
Is the voltage above 0.2 volts?
Ye s>>
Repair the (C29) Mode Door 1 Driver circuit for a short to
voltage.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
2.RUN THE ACTUATOR DTC DETECTION TEST
Turn the ignition off.
Reconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
With the scan tool in HVAC, select System Tests and then select Actuator DTCDetection. When the test is com-
plete, select View DTCs.
Does the scan tool only display: B1042–PANEL MODE DOOR 1 CONTROL CIRCUIT HIGH?
Ye s>>
Replace the A/C Heater Control in accordance with the Service Information.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).
No, Other DTC(s) Displayed
Page 4982 of 5267

Theory of Operation
The A/C Heater Control drives the Mode Door 2 (Defrost to Floor) Actuator viathe(C801)ModeDoor2Driver
circuit and the (C34) Common Door Driver circuit. All of the door actuatorsshare the (C34) Common Door Driver
circuit. Inside the A/C Heater Control, each door actuator has its own unique driver, but all share a single common
door driver circuit. Due to the shared circuitry similar DTCs can set at thesame time for multiple actuators depend-
ing upon the type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C801) Mode Door 2 Driver circuit is shorted to ground.
Possible Causes
(C801) MODE DOOR 2 DRIVER CIRCUIT SHORTED TO GROUND
(C801) MODE DOOR 2 DRIVER CIRCUIT SHORTED TO OTHER DOOR DRIVER CIRCUIT(S)
MODE DOOR 2 (DEFROST TO FLOOR) ACTUATOR
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C801) MODE DOOR 2 DRIVER CIRCUIT FOR A SHORT TO GROUND
NOTE: If present, diagnose and repair DTC B10AB Right Blend
Door Control Circuit High or B10AA Right Blend Door Control Cir-
cuit Low before proceeding.
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Measure the resistance of the (C801) Mode Door 2 Driver circuit
between ground and the A/C Heater Control C1 harness connector.
Istheresistancebelow10kohms?
Ye s>>
Repair the (C801) Mode Door 2 Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
Page 4986 of 5267

Theory of Operation
The A/C Heater Control drives the Mode Door 2 (Defrost to Floor) Actuator viathe(C801)ModeDoor2Driver
circuit and the (C34) Common Door Driver circuit. All of the door actuatorsshare the (C34) Common Door Driver
circuit. Inside the A/C Heater Control, each door actuator has its own unique driver, but all share a single common
door driver circuit. Due to the shared circuitry similar DTCs can set at thesame time for multiple actuators depend-
ing upon the type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C801) Mode Door 2 Driver circuit is shorted to ground.
Possible Causes
(C801) MODE DOOR 2 DRIVER CIRCUIT SHORTED TO GROUND
(C801) MODE DOOR 2 DRIVER CIRCUIT SHORTED TO OTHER DOOR DRIVER CIRCUIT(S)
MODE DOOR 2 (DEFROST TO FLOOR) ACTUATOR
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C801) MODE DOOR 2 DRIVER CIRCUIT FOR A SHORT TO GROUND
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Measure the resistance of the (C801) Mode Door 2 Driver circuit
between ground and the A/C Heater Control C1 harness connector.
Istheresistancebelow10kohms?
Ye s>>
Repair the (C801) Mode Door 2 Driver circuit for a short to
ground.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
Page 4990 of 5267

Theory of Operation
The A/C Heater Control drives the Mode Door 2 (Defrost to Floor) Actuator viathe(C801)ModeDoor2Driver
circuit and the (C34) Common Door Driver circuit. All of the door actuatorsshare the (C34) Common Door Driver
circuit. Inside the A/C Heater Control, each door actuator has its own unique driver, but all share a single common
door driver circuit. Due to the shared circuitry similar DTCs can set at thesame time for multiple actuators depend-
ing upon the type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C801) Mode Door 2 Driver circuit is shorted to voltage.
Possible Causes
(C801) MODE DOOR 2 DRIVER CIRCUIT SHORTED TO VOLTAGE
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C801) MODE DOOR 2 DRIVER CIRCUIT FOR A SHORT TO VOLTAGE
NOTE: If present, diagnose and repair DTC B10AB Right Blend
Door Control Circuit High or B10AA Right Blend Door Control Cir-
cuit Low before proceeding.
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
Measure the voltage of the (C801) Mode Door 2 Driver circuit.
Is the voltage above 0.2 volts?
Ye s>>
Repair the (C801) Mode Door 2 Driver circuit for a short to
voltage.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
2.RUN THE ACTUATOR DTC DETECTION TEST
Turn the ignition off.
Reconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
With the scan tool in HVAC, select System Tests and then select Actuator DTCDetection. When the test is com-
plete, select View DTCs.
Does the scan tool only display: B1048–FLOOR/DEFROST MODE DOOR CONTROL CIRCUIT HIGH?
Ye s>>
Replace the A/C Heater Control in accordance with the Service Information.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).
No, Other DTC(s) Displayed
Page 4993 of 5267

Theory of Operation
The A/C Heater Control drives the Mode Door 2 (Defrost to Floor) Actuator viathe(C801)ModeDoor2Driver
circuit and the (C34) Common Door Driver circuit. All of the door actuatorsshare the (C34) Common Door Driver
circuit. Inside the A/C Heater Control, each door actuator has its own unique driver, but all share a single common
door driver circuit. Due to the shared circuitry similar DTCs can set at thesame time for multiple actuators depend-
ing upon the type of short, its location, and the direction the actuator is moving when the short is present.
When Monitored:
When the Actuator DTC Detection Test is executed.
Set Condition:
If the (C801) Mode Door 2 Driver circuit is shorted to voltage.
Possible Causes
(C801) MODE DOOR 2 DRIVER CIRCUIT SHORTED TO VOLTAGE
A/C HEATER CONTROL
Diagnostic Test
1.CHECK (C801) MODE DOOR 2 DRIVER CIRCUIT FOR A SHORT TO VOLTAGE
Turn the ignition off.
Disconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
Measure the voltage of the (C801) Mode Door 2 Driver circuit.
Is the voltage above 0.2 volts?
Ye s>>
Repair the (C801) Mode Door 2 Driver circuit for a short to
voltage.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8
- ELECTRICAL/ELECTRONIC CONTROL MODULES -
STANDARD PROCEDURE).
No>>
Go To 2
2.RUN THE ACTUATOR DTC DETECTION TEST
Turn the ignition off.
Reconnect the A/C Heater Control C1 harness connector.
Turn the ignition on.
With the scan tool in HVAC, select System Tests and then select Actuator DTCDetection. When the test is com-
plete, select View DTCs.
Does the scan tool only display: B1048–FLOOR/DEFROST MODE DOOR CONTROL CIRCUIT HIGH?
Ye s>>
Replace the A/C Heater Control in accordance with the Service Information.
Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL
MODULES - STANDARD PROCEDURE).
No, Other DTC(s) Displayed