INFINITI Q50 HYBRID 2015  Dismantling Guide 1. About the INFINITI Q50 HYBRID 
This hybrid electric vehicle (HEV) uses two types of batteries. One is a 12-volt battery that is the same as 
the battery in vehicles powered by internal combustion e

Page 7 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide 1-1.2 Interior 
Interior components referenced in this manual are as follows:A. Assist charge gauge B. Energy flow display *1 C. READY indicator (green) 
D. Energy flow display *1 E. Trunk lid release

Page 10 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide 2. Basic High Voltage Information 
2-1 Battery Information 
The Q50 HYBRID utilizes two batteries in order to supply both high and low voltage. 
2-1.1 12-Volt Battery• The Q50 HYBRID contains a conv

Page 12 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide No. Component Location Description� High voltage Battery
Trunk area (behind
rear seat back) The high voltage battery stores and outputs
DC power (Maximum voltage 400V) needed to
propel the vehicle.
DC

Page 14 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide 2-5 High Voltage Safety System 
The high voltage safety system is intended to help keep vehicle occupants and emergency responders safe 
from high voltage electricity.• A high voltage fuse provides

Page 20 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide 3-4 How to Handle a Damaged Vehicle 
3-4.1 High Voltage System Shut-Down Procedure 
Any of the following procedures can shut down the high voltage system. The dismantling operation canonly 
begin afte

Page 21 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide Powering Down the High Voltage System 
The high voltage system can be shut down with any 1 of the following procedures:• Turn OFF the power switch and disconnect the 12-volt battery. Refer to
Primar

Page 22 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide 5. Open the trunk using any of the following:NOTE: 
The trunk release power cancel switch must be in
the ON position in order for the trunk to be opened
using any of the methods below.
a. push-button

Page 23 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide NOTE: 
If the electrical release does not work, the trunk will have to be forced open.6. Open the 12-volt battery service access cover. 
7. Disconnect negative (-) battery cable and cover it withinsul

Page 25 of 55

INFINITI Q50 HYBRID 2015  Dismantling Guide 4. Disengage pawls (A) of underhood fuse panel cover andremove underhood fuse panel cover (1) . 
NOTE:
: Arrow in illustration depicts vehicle front
direction.
5. Pull underhood fuse panel (1) out by