battery RENAULT SCENIC 2008 J84 / 2.G Electrical Equipment - Multiplexing Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2008, Model line: SCENIC, Model: RENAULT SCENIC 2008 J84 / 2.GPages: 25, PDF Size: 0.09 MB
Page 14 of 25
88B - 14
MULTIPLEXING
Fault finding - Interpretation of faults
88B
V4 MR-372-J84-88B050$700_eng.mif
MULTIPLEXING
Fault finding - Interpretation of faults
FAULTY SEGMENT ON THE MULTIPLEX NETWORK
NOTESFirst check that the computer at the end of the faulty segment is properly
powered (earth, + battery, + accessories or + after ignition).
Always check the computer conformity.
If the Protection and Switching Unit computer is not detected, apply the appropriate
fault finding procedure (see 87G, Engine Compartment Connection Unit, Fault
Finding Chart, ALP1).
IMPORTANT
The tool may not be able to pinpoint the faulty segment(s) exactly. It then suggests
several segments that could be faulty. In this event, repair the segment closest to the
diagnostic socket.
Isolate the faulty segment by disconnecting both ends of the segment. Check the condition of the connections (see
Technical Note 6015A Repairing electrical wiring, Multiplex: Multiplex network, Repair).
Check the continuity and insulation of the multiplex line H and multiplex line L lines between the two connectors
on the isolated segment.
Refer to the vehicle's multiplex network diagram for the allocation of tracks on the computers and connections.
Perform the necessary operations to check the continuity of the two lines (for example, replacing the wiring).
Make sure that the computer present in the vehicle is compatible with the Scénic II ph2 and that the signals it is
producing are correct.
Reconnect the segment.
Run the multiplex network test again using the diagnostic tool.
Is the segment still declared faulty?
NoEnd of fault finding.
Are there other faulty segments?
Yes
NoTest the multiplex network again to check the continuity and
insulation of the multiplex line H and multiplex line L lines
between the end of the faulty segment and the diagnostic
socket at connections 133B and 133C (see diagnostic
socket diagram).
Apply the same procedure to each segment.
Yes
AFTER REPAIRRun the multiplex network test again using the diagnostic tool.
Clear the stored faults on all the computers connected to the network.
Deal with any other faults.
MR-372-J84-88B050$700_eng.mif
Page 15 of 25
88B - 15
MULTIPLEXING
Fault finding - Interpretation of faults
88B
V4 MR-372-J84-88B050$700_eng.mif
FAULTY COMPUTER
NOTES–Make sure the computers installed in the vehicle are the correct type and are
compatible with the Scénic II ph2.
–Check the power supply of the computers (earth, + battery, + accessories or + after
ignition).
Make sure that the computer wake-up mode is in full working order on the vehicle and properly assimilated by the
computers.
The wake-up mode is:
–timed power supply: UCH, instrument panel.
–+ accessories feed: Protection and Switching Unit, Heating and Air Conditioning System, Central
Communication Unit.
–+ After ignition feed: Injection, ABS/ESP, airbag, Electric Power-Assisted Steering, Automatic
Transmission, LPG/Natural Gas Fuel, Steering column lock, Driving School Unit, Automatic Parking
Brake, Parking Distance Control.
–+ After ignition + dipped headlights: Xenon bulbs.
IMPORTANT
Only establish dialogue with the discharge bulbs with + after ignition and the dipped headlights on.
–Switch to computer diagnostics mode.
Attempt to establish dialogue with computers.
●No dialogue from computers to diagnostic tool: see ALP 1
No dialogue with the computer or computers not communicating with the diagnostic tool.
Check the connections to the computers and that there are no open circuits.
If there is a repair procedure (see Technical Note 6015A, Repairing electrical wiring, wiring:
precautions for repairs), repair the connectors, otherwise change them.
●The computers only produce partial information when identified:
Check in the MR or World Vehicle Database to see that the computer really is compatible with the
Scénic II ph2.
Make sure the CLIP diagnostic tool update is recent enough to handle Scénic II ph2 faults.
If after these tests no faults or open or short circuits have been detected, contact your Techline.
AFTER REPAIRRun the multiplex network test again using the diagnostic tool.
Clear the stored faults on all the computers connected to the network.
Deal with any other faults.
Page 17 of 25
88B - 17
MULTIPLEXING
Fault finding - Interpretation of faults
88B
V4 MR-372-J84-88B050$700_eng.mif
MULTIPLEX NETWORK NOT OPERATIONAL
NOTESFirst check that the computer at the end of the faulty segment is properly
powered (earth, + battery, + accessories or + after ignition).
Always check the computer conformity.
IMPORTANT
Switch off the ignition or remove the RENAULT card from the card reader, check that
the side lights are off and wait for 1 minute.
Finding the fault
type
NOTESUse the diagram of the multiplex network of the vehicle
(diagram of the diagnostic socket).
Measure the resistance between connections 133B and 133C on the diagnostic socket.
What is the resistance?
0 ΩΩ Ω ΩThe two lines are in short circuit (see Introduction: Repair advice).
Check that there is earth, + battery feed, + accessories feed or + after ignition feed
at the airbag computer and UCH terminals. To allocate the connections on the
computers and connections, use the vehicle diagrams for the airbag computer (756)
and the UCH (645).
For each 133B and 133C connection between the different vehicle computers, check
there is no interference resistance and no short circuit to earth or to the + battery feed.
60 ΩΩ Ω Ω
± 10 ΩΩ Ω Ω
Between 70 ΩΩ Ω Ω
and 110 ΩΩ Ω Ω
AFTER REPAIRRun the multiplex network test again using the diagnostic tool.
Clear the stored faults on all the computers connected to the network.
Deal with any other faults.
Page 23 of 25
88B - 23
MULTIPLEXING
Fault finding - Fault Finding Chart
88B
V4 MR-372-J84-88B050$900_eng.mif
ALP 1
CONTINUED 3
NOTESVehicle computer power supply for fault finding:
insert the vehicle card in the card reader.
Press and hold (over 5 seconds) the Start button in the absence of start conditions (for
example: selecting a gear).
Connect the diagnostic tool and perform the required operations.
IMPORTANT
To supply the discharge bulb computers, switch on the dipped headlights.
Use Technical Note Wiring diagram, Scénic II ph2.
Check the following connections on the diagnostic socket:
BP 32 + battery feed
NAM and MAM Earth
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Computer connected to multiplex line V
If the fault is still present, check the continuity and the insulation of the following connections:
Multiplex line H (133B of component 225)
Multiplex line L (133C of component 225)
Use a multimeter to check that the voltages at the terminals of component 225 are approximately:
–2.5 V between multiplex line H (133B) and the earth (NAM and MAM) (Average values)
–2.5 V between multiplex line L (133C) and the earth (NAM and MAM) (Average values).
Refer to the Introduction - “Repair advice” to detect a short circuit on the vehicle's multiplex network.
Page 24 of 25
88B - 24
MULTIPLEXING
Fault finding - Fault Finding Chart
88B
V4 MR-372-J84-88B050$900_eng.mif
ALP 2No topology diagram or configuration table display at the end of
the multiplex network test
The topology cannot be displayed under the following conditions:
1. The two computers storing the multiplex network configuration have failed to respond.
2. The multiplex network is not operational, therefore dialogue is impossible.
3. The two computers storing the multiplex network configuration do not have the same configurations.
4. On the multiplex network tab on the configuration screen, an incorrect network version number has been
entered on one of the two computers storing the network configuration.
5. No network version has been entered on the two computers that store the configuration.
1 – The two computers storing the multiplex network configuration have failed to respond.
Check first that the computers storing the configuration (Airbag and UCH) are correctly supplied (earth,
+ battery, + accessories or + after ignition).
Check the condition of the multiplex network and the continuity and insulation of the multiplex line H and
multiplex line L lines between the computers storing the configuration.
2 – The multiplex network is not operational, therefore dialogue is impossible (see Network not
operational fault).
3 – The two computers that store the multiplex network configuration do not have the same configurations
(see Network configurations configuration).
4 – On the multiplex network tab on the configuration screen, an incorrect network version has been
entered on one of the two computers storing the network configuration (see Network configurations
configuration).
5 – No diagram version has been entered into the two calculators that store the configuration (see Network
configurations configuration).