sensor RENAULT SCENIC 2008 J84 / 2.G Gas Injection LPG 3000 Owner's Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2008, Model line: SCENIC, Model: RENAULT SCENIC 2008 J84 / 2.GPages: 107, PDF Size: 0.31 MB
Page 85 of 107

17C-85
MR-372-J84-17C000$708.mif
V2
GAS INJECTION
Fault finding - Interpretation of parameters
LPG 3000
Program No.
Vdiag No: 08/10
17C
PR007
LPG TANK SENDER SIGNAL VOLTAGE
NOTESThere must be no present or stored faults.
Ignition on, engine stopped.
Using the LPG tank sender signal voltage value PR007 and measure the resistance, using a multimeter between
tracks A and C (for Mégane 2 ) or tracks A1 and A2 (for Logan).
Check the consistency between these values using the table below.
In the event of inconsistency, check for earth on track D or C (for Mégane 2 ) or track 3 or 4 (for Logan) of LPG
tank pressure sensor connector.
Repair if necessary.
Check the insulation against earth, continuity and the absence of interference resistance of the connections
between:
For Mégane 2:
LPG computer track A4
LPG computer track D3
For Logan:
LPG computer track B2
LPG computer track D3track A of the LPG tank sender
track C of the LPG tank sender
track A2 of the LPG tank sender
track A1 of the LPG tank sender unit
Repair if necessary.
Pressure sensor voltage
in V (± 0.5 V)Needle position
4Full
1Reserve
0Empty
AFTER REPAIRFollow the instructions to confirm repair.
GAZ3000_V08_PR007 / GAZ3000_V10_PR007
Page 86 of 107

17C-86
MR-372-J84-17C000$708.mif
V2
GAS INJECTION
Fault finding - Interpretation of parameters
LPG 3000
Program No.
Vdiag No: 08/10
17C
PR112
LPG PRESSURE DOWNSTREAM OF EXPANSION VALVE
NOTESThere must be no present or stored faults.
Ignition on, engine stopped.
Check that the LPG pressure downstream of the expansion valve is not more than 800 mbar greater than the
manifold pressure PR001 Manifold pressure.
Check the pressure value using parameters PR001 Manifold pressure, PR003 Pressure difference:
LPG/manifold and PR112 LPG pressure downstream of expansion valve and ensure that
PR003 = PR112 - PR001.
If the fault is still present, manipulate the wiring harness between the LPG computer and the LPG pressure/
temperature sensor to produce a status change.
Check the connection and condition of the LPG pressure/temperature sensor and its connections.
If necessary, repair or replace the connector.
Check for + 5V on track 1 (for Mégane 2) or track 3 (for Logan) of the LPG pressure/temperature sensor in LPG
mode. Check the insulation in relation to earth and the continuity and the absence of interference
resistance on the connection between:
For Mégane 2:
LPG computer track A3
For Logan:
LPG computer track A3track 1 of the LPG temperature/pressure sensor
track 3 of the LPG temperature/pressure sensor
Repair if necessary.
Check for earth on track 3 (for Mégane 2) or track 1 (for Logan) of the LPG pressure/temperature sensor in
LPG mode.
Check the insulation in relation to + 12V and the continuity and absence of interference resistance on
the connection between:
For Mégane 2:
LPG computer track B3
For Logan:
LPG computer track B3track 3 of the LPG temperature/pressure sensor
track 1 of the LPG temperature/pressure sensor
Repair if necessary.
AFTER REPAIRFollow the instructions to confirm repair.
GAZ3000_V08_PR112 / GAZ3000_V10_PR112
Page 87 of 107

17C-87
MR-372-J84-17C000$708.mif
V2
GAS INJECTION
Fault finding - Interpretation of parameters
LPG 3000
Program No.
Vdiag No: 08/10
17C
PR112
CONTINUED
Check the insulation, continuity and the absence of interference resistance on the connection between:
For Mégane 2:
LPG computer track C4
For Logan:
LPG computer track C3
LPG computer track E2track 2 of the LPG pressure/temperature sensor
track 4 of the LPG pressure/temperature sensor
track 2 of the LPG pressure/temperature sensor
Repair if necessary.
If the fault is still present, replace the LPG pressure/temperature sensor.
If the fault is still present, check the expansion valve (see MR 364 Mechanical, 17D, LPG injection).
AFTER REPAIRFollow the instructions to confirm repair.
Page 100 of 107

17C-100
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 2 LPG sender fault
For Mégane II
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESCheck that there is LPG in the tank.
Disconnect the LPG tank sender connector and check the voltage of the sensor signal using parameter
PR007 LPG tank sender signal voltage.
Replace the sensor if the signal voltage is not approximately:4.8 V tank full
1 V in reserve
0.2 V tank empty
Check for earth on track C (for Mégane 2) of the LPG tank connector.
Repair if necessary.
Check the insulation in relation to earth and the continuity and the absence of interference resistance on
the connection between:
For Mégane 2:
LPG computer track B1 track B of the LPG tank sender
If the fault is still present, check the intermediate connectors (R2 track 36 and R34 track 34 for Mégane 2).
Repair if necessary.
If the fault is still present, check the LPG tank pressure sensor (see MR 364 Mechanical, 17D, LPG injection).
AFTER REPAIRCheck using the diagnostic tool.
GAZ3000_V08_ALP2 / GAZ3000_V10_ALP2
Page 101 of 107

17C-101
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 2
CONTINUED 1
For Logan
IMPORTANT
When carrying out an operation on an LPG supply circuit component, consult the safety instructions
(see 17D, Gas injection, Introduction, Safety instructions for all operations).
NOTESAsk the customer if the problem always arises.
If it is not the case, do not replace the sensor, as it is not the cause.
Is the fault that the tank is not displaying full when it has just been filled with LPG?
Check that the tank has just been filled with LPG, otherwise refill it.
If the customer complaint is reproduced, continue fault finding.
If not, the fault does not always arise. Do not replace the sensor and deal
with the next customer complaint.
Disconnect the connector from the LPG tank sender and measure
the resistance between tracks A1 and A.
Replace the LPG tank sender if the resistance value is less than 5 kOhms,
because the sensor is incorrect.
If the fault is still present, contact the Techline.
Is the fault related to the LPG warning not being displayed when the tank is empty?
NOYES
YES
A
AFTER REPAIRCheck using the diagnostic tool.
Page 102 of 107

17C-102
MR-372-J84-17C000$944.mif
V2
GAS INJECTION
Fault finding - Fault finding chart (ALP)
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
ALP 2
CONTINUED 2
Check that the tank is empty, otherwise empty it by going for a drive.
If the customer complaint is reproduced, continue fault finding.
If not, the fault does not always arise. Do not replace the sensor and deal with the next customer complaint.
Disconnect the connector from the LPG tank sender and measure the resistance between tracks A1 and A.
Replace the LPG tank sender if the resistance value is greater than 2.1 kOhms, because the sensor is incorrect.
If the fault is still present, contact the Techline.
A
YES
AFTER REPAIRCheck using the diagnostic tool.