lights RENAULT SCENIC 2009 J84 / 2.G Air Conditioning Climate Control Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: SCENIC, Model: RENAULT SCENIC 2009 J84 / 2.GPages: 60
Page 2 of 60
62B - 2
CLIMATE CONTROL
Fault finding – Introduction62B
V3 MR-372-J84-62B000$010.mif
Vdiag No.: 44
162BCLIMATE CONTROL
Fault finding – Introduction
1. SCOPE OF THIS DOCUMENT
This document presents the fault finding procedure applicable to all computers with the following specifications:
2. PREREQUISITES FOR FAULT FINDING
Documentation type:
Fault finding procedures (this manual):
–Assisted fault finding (integrated into the diagnostic tool), Dialogys.
Wiring Diagrams:
–Visu-Schéma (CD-ROM), paper version.
Type of diagnostic tools:
–CLIP
Type of special tooling required:
3. RECAP
Procedure
To run fault finding on the vehicle's computers, switch on the ignition in fault finding mode (forced + after ignition
feed).
Proceed as follows:
–Renault card in the card reader (keyless vehicle scenario 1, standard, not hands-free and scenario 2, top of
the range, hands-free),
–press and hold the Start button (longer than 5 seconds) with start-up conditions not fulfilled,
–then connect the diagnostic tool and perform the required operations.
To cut off + after ignition, proceed as follows:
–disconnect the diagnostic tool,
–press the Start button twice briefly (less than 3 seconds),
–check that the + after ignition feed has been cut off by checking that the computer warning lights on the
instrument panel have gone out. Vehicle: Scénic II
Function concerned: Climate controlComputer name: Careg
Program No.: 0003
Vdiag No.: 44
SPECIAL TOOLING REQUIRED
Multimeter
Elé. 1681 Universal bornier
Note:
The left-hand and right-hand xenon bulb computers are powered when the dipped headlights are lit. Fault finding
procedures can only be carried out on them after the ignition has been switched on in fault finding mode (+ after
ignition imposed) and the dipped headlights are on.
ACREG X84 1.1
Edition 2
MR-372-J84-62B000$010.mif
Page 3 of 60
62B - 3
CLIMATE CONTROL
Fault finding – Introduction62B
V3 MR-372-J84-62B000$010.mif
Vdiag No.: 44
Faults:
Faults are declared as either present or stored (depending on whether they appeared in a certain context and have
disappeared since, or whether they remain present but have not been diagnosed within the current context).
The present or stored status of faults should be taken into consideration when the diagnostic tool is used after the
+ after ignition feed has been supplied (without acting on the system components).
For a present fault, apply the procedure described in the Interpretation of faults section.
For a stored fault, note the faults displayed and apply the instructions in the Notes section.
If the fault is confirmed when the notes are applied, the fault is present. Deal with the fault.
If the fault is not confirmed, check:
–The electrical lines which correspond to the fault,
–The connectors on these lines (corrosion, bent pins, etc.),
–The resistance of the faulty component,
–The condition of the wiring (insulation melted or cut, chafing, etc.).
Conformity check
The aim of the conformity check is to check statuses and parameters that do not produce a fault display on the
diagnostic tool when they are inconsistent. Therefore, this stage is used to:
–carry out fault finding on faults that do not have a fault display, and which may correspond to a customer complaint,
–check that the system is operating correctly and that there is no risk of a fault recurring after repairs.
This section gives the fault finding procedures for statuses and parameters and the conditions for checking them.
If a status is not behaving normally or a parameter is outside the permitted tolerance values, consult the
corresponding fault finding page.
Notes about the conformity check for the air conditioning system
All variables (statuses and parameters) and commands required for the air conditioning function are divided into four
sub-functions:
–the COLD LOOP sub-function, which groups together all the information required for producing cold air,
–the USER SELECTION sub-function, which groups together all the information relating to the user's requests
(buttons pressed, warning lights, etc.),
–the HEATING sub-function, which groups together all the information required for producing warm air,
–the PASSENGER COMPARTMENT VENTILATION sub-function, which groups together all the information
relating to ventilation, distribution and air distribution within the passenger compartment.
ACREG X84 1.1
Edition 2
Page 7 of 60
62B - 7
CLIMATE CONTROL
Fault finding – System operation62B
V3 MR-372-J84-62B000$020.mif
Vdiag No.: 44
CLIMATE CONTROL
Fault finding – System operation
GENERAL INFORMATION:
The climate control system fitted on the SCENIC is controlled by four computers. This system is called a
DISTRIBUTED FUNCTION. Fault finding on the climate control is performed in two different ways using the
diagnostic tool. The first method consists of performing fault finding on each computer which allows
communications to be established with just one computer (select the climate control computer). The second
procedure consists of performing fault finding on each function which allows communications to be established
with all four computers of the AIR CONDITIONING function. These two fault finding methods are described in the
introduction of this repair manual.
DESCRIPTION OF THE OPERA
TION OF THE CLIMATE CONTROL COMPUTER:
The climate control computer controls the passenger compartment ventilation, the distribution motor, the mixing
motor and the recirculation motor.
The climate control computer also controls two sensors, these being the interior temperature sensor and the solar
radiation sensor.
The two sensors and the three motors are connected to the climate control computer by wire connections. The
climate control computer controls the passenger compartment ventilation using a modulated control signal (square
signal) sent to a power module (wire connection).
All other signals used by the climate control computer or transmitted by this computer to other computers are sent on
the multiplex network.
Cold air production (cold loop) and warm air production (heating) are controlled by the other three computers
involved in the Air conditioning function (UCH, protection and switching unit and injection computer).
The main signals used by the climate control computer are:
–+ 12 V sidelights,
–0 V rheostat controlled,
–exterior temperature,
–engine coolant temperature,
–engine operating status,
–engine speed,
–electrical power consumed,
–request to set the blown air temperature.
OPERA
TING NOTES:
–When the engine is switched off, the passenger compartment blower unit operates approximately 30% slower than
the requested speed (control panel setting).
–If any of the actuators are faulty, the air conditioning can no longer control them, but the setting requests are still
displayed on the control panel: warning lights light up, display of symbols on the control panel (distribution motor
position, passenger compartment blower speed, AC symbol, etc.).
–If the exterior temperature sensor is faulty, the climate control computer is switched on 5 seconds after the
ignition is switched on (this allows a fault to be identified as fault finding cannot be performed on the exterior
temperature sensor by the UCH).
ACREG X84 1.1
Edition 2
MR-372-J84-62B000$020.mif
Page 9 of 60
62B - 9
CLIMATE CONTROL
Fault finding – Allocation of computer tracks62B
V3 MR-372-J84-62B000$030.mif
Vdiag No.: 44
CLIMATE CONTROL
Fault finding – Allocation of computer tracks
Allocation of climate control computer tracks.
Computer
tracksFunctions Sensor - actuator tracks
Connector A
1CAN L
2not used
3not used
4solar sensor signal track 2 of the solar sensor
5interior temperature sensor signal track 4 of the interior temperature sensor
6computer earth
7CAN H
8not used
9+ 12 V side lightsleft-hand side light fuse in the Protection and Switching
Unit (7.5 A)
10 + 12 V accessories feed passenger compartment fuse (15 A)
11 + 12 V before ignition feed passenger compartment fuse (20 A)
12 0 V sensors (solar, interior temperature)track 1 of the solar sensor and track 5 of the interior
temperature sensor
Connector B
1recirculation motor control track 5 of the recirculation motor
2not used
3not used
4not used
5not used
6not used
7passenger compartment blower module
controltrack 6 of the passenger compartment blower module
6-track connector
812 V supply of the mixing and distribution
motorstrack 2 of the mixing and distribution motors
9not used
10 recirculation motor control track 6 of the recirculation motor
11 distribution motor control track 1 of the distribution motor (coil B2)
12 distribution motor control track 6 of the distribution motor (coil A2)
13 distribution motor control track 3 of the distribution motor (coil B1)
14 distribution motor control track 4 of the distribution motor (coil A1)
15 mixing motor controltrack 1 of the mixing motor for B and C84 and track 3
of the mixing motor for J84 (B2 winding)
16 mixing motor control track 6 of the mixing motor (A2 winding)
17 mixing motor controltrack 3 of the mixing motor for B and C84 and track 1
of the mixing motor for J84 (B1 winding)
18 mixing motor control track 4 of the mixing motor (A1 winding)
ACREG X84 1.1
Edition 2
MR-372-J84-62B000$030.mif
Page 40 of 60
62B - 40
CLIMATE CONTROL
Fault finding – Conformity check62B
V3 MR-372-J84-62B000$090.mif
Vdiag No.: 44
MAIN SCREEN
NOTESOnly carry out this conformity check after a full check with the diagnostic tool (fault
reading and configuration checks).
Test conditions: engine off, ignition on (forced 12 V After ignition).
Air conditioning off (air conditioning compressor not triggered).
Special note:
The various conformity checks for the air conditioning function are explained in the
Introduction section.
Note:
This page lists the statuses and parameters provided by the climate control computer
but which are not associated with the four sub-functions given in the conformity check
(PASSENGER COMPARTMENT VENTILATION, COLD LOOP, USER SELECTION
and HEATING sub-functions).
Order FunctionParameter or Status
checked or Action Display and Notes Fault finding
1Electrical
suppliesPR092:Battery voltage10.5 < X < 14.4 VIn the event of a fault, see
the interpretation of this
parameter
ET007:+ after ignition
computer feedABSENT: Ignition off.
PRESENT: Ignition on.In the event of a fault, refer
to the interpretation of
this status.
ET002:+ 12 V side
lightsABSENT: Side lights
off.
PRESENT: Side lights
on.In the event of a fault,
consult the interpretation
of this status (see 87B,
Passenger compartment
connection unit).
PR122:Night-time
lighting level6% = minimum lighting
level.
99% = maximum
lighting level.
(side lights off: 102%)In the event of a fault, refer
to the interpretation of
parameter PR111 Lighting
dimmer voltage (see 83A,
Instrument panel).
ACREG X84 1.1
Edition 2
Page 54 of 60
62B-54
CLIMATE CONTROL
Fault finding – Fault Finding Chart62B
V3 MR-372-J84-62B000$110.mif
Vdiag No.: 44
ALP 13 No control panel lighting
NOTESOnly refer to this customer complaint after a full check of the multiplex network
and the air conditioning with the fault finding tool.
Special notes:
With the ignition on, the control panel screen is permanently on but the panel buttons
only light up when the sidelights are switched on.
Note:
If the external temperature sensor is faulty, the climate control computer is
switched on 5 seconds after the ignition is switched on (this allows a fault to be
identified as fault finding cannot be performed on the external temperature sensor
by the UCH).
Is the fault common to other components (instrument panel,
multifunction display, electric window buttons, etc.)?
YES
Switch on the ignition and switch on the side lights to check
there is a 12 V supply on track 6 of the brown 12-track
connector (PPH2) of the Protection and Switching Unit.
Is there a 12 V supply?
YES
Check the connection and the condition of the connectors at the air conditioning control panel
output.
Repair if necessary.
Check the insulation, continuity and absence of interference resistance on the following
connection:
Air conditioning computer 12-track connector
track 9
Repair if necessary.Protection and Switching Unit brown 12-track
(PPH2) connector
track 6
NO
NOPerform fault finding on the
protection and switching unit.
AFTER REPAIRPerform a complete check using the diagnostic tool.
ACREG X84 1.1
Edition 2