PETROL INJECTION
Fault finding - System operation
17B
17B - 7
PETROL INJECTION
Fault finding - System operation
17B
17B - 7V9 MR-372-J84-17B050$094.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54PETROL INJECTION
Fault finding - System operation
1. SYSTEM OPERATION
Composition
The injection system consists of the:
– accelerator potentiometer,
– clutch pedal switch,
– TDC sensor,
– atmospheric pressure sensor,
– air temperature sensor,
– coolant temperature sensor,
– upstream oxygen sensor,
– downstream oxygen sensor,
– cruise control switch,
– steering column switch,
– cruise control on/off switch,
– fuel vapour absorber,
– injection computer,
– motorised throttle valve,
– 4 injectors,
– 4 pencil coils,
– pinking sensor,
– camshaft dephaser solenoid valve (non-LPG K4M only),
– camshaft position sensor (non-LPG K4M only),
– turbocharging pressure sensor (F4R turbo only)
– electric coolant pump (F4R turbo only),
– wastegate solenoid valve (only on F4R Turbo),
– turbocharging solenoid valve (only on F4R-Turbo)
Computer
128 track SAGEM type S3000 FLASH EEPROM computer controlling injection and ignition.
Multipoint injection in sequential mode.
Connections to the other computers:
– air conditioning,
– UCH,
– protection and switching unit (UPC)
– Automatic Gearbox Electronic Control Unit (AUTO).
– airbag,
– ABS/ESP,
– instrument panel.
MR-372-J84-17B050$094.mif
Page 10 of 230
PETROL INJECTION
Fault finding - System operation
17B
17B - 10
PETROL INJECTION
Fault finding - System operation
17B
17B - 10V9 MR-372-J84-17B050$094.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
Fuel supply management
Fuel is supplied by the fuel pump. It is controlled each time the ignition is switched on, for 1 second, to provide a
certain pressure level in the circuit, and thereby achieve a correct start, particularly if the vehicle has been unused
for a long time.
When the engine is running, the fuel pump relay is always controlled.
Control of the petrol pump relay can be viewed through status ET047 Petrol pump control circuit.
The petrol tank is vented by way of a canister filled with activated charcoal that traps the vapour from the petrol tank.
This canister is bled via the engine vacuum pipe. It enters the inlet plenum via a hose, whose section is controlled by
a bleed valve. It is controlled by the injection computer via the opening cycle ratio. For reasons of engine instability
or canister bleed solenoid valve operating noise emitted by the vehicle, there are two possible frequencies for
controlling the canister bleed solenoid valve:
●a low frequency 8Hz,
●a high frequency 20 Hz.
The frequency of the control opening cycle ratio depends on the engine speed.
Bleed the canister to drain it as it fills, to limit vapour release into the air if a canister is saturated for example.
Air supply management
The idling speed regulator performs all the calculations required for physical control of the idling speed actuator: the
motorised throttle. The functional component of the regulator is adaptive (variation programming and ageing).
If the idling speed regulation conditions are observed, ET054 Idle speed regulation is ACTIVE, the idling speed
regulator continuously positions the motorised throttle to maintain the engine speed at its idling setpoint. The
motorised throttle opening ratio necessary to comply with the speed setpoint is then given by parameter PR091
Idling speed regulation theoretical OCR.
Note on parameter PR091:
This parameter uses only 2 parameters accessible in fault finding frame: PR444 Idle speed integral correction and
PR090 Idle speed regulation programming value which is the integral adaptive action.
–PR090 Idling speed regulation programming value is a stored parameter designed to program dispersion and
engine ageing for the idling speed regulator. The programming is carried out only when the engine is idling and
warm, and no electrical consumer (air conditioning, fan assembly, power assisted steering) is operating. Therefore
it adjusts slowly.
–PR444 Idling speed regulation integral correction is continuously calculated to take into account the air required
by consumers.
Page 14 of 230
PETROL INJECTION
Fault finding - System operation
17B
17B - 14
PETROL INJECTION
Fault finding - System operation
17B
17B - 14V9 MR-372-J84-17B050$094.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
3. OBD management
Managed OBD programming is as follows:
– catalytic converter operational fault finding,
– upstream oxygen sensor operational fault finding,
– misfiring fault finding with two levels of detection: pollutant misfiring and catalytic converter breakage
misfiring,
– fuel supply system fault finding.
The misfiring and fuel supply system fault finding is performed continuously.
The operational fault finding for the upstream sensor and the catalytic converter can be only be carried out once per
journey, and can never occur at the same time.
OBD fault manager:
The OBD faults manager does not replace or modify conventional electrical fault management. Perform to comply
with OBD standard.
The requirements are:
●storing OBD faults,
●illuminate the OBD warning light for all faults where the OBD emission thresholds are exceeded,
●flash the OBD warning light for misfire faults damaging the catalytic converter.
Operating principle.
If a fault is detected and confirmed during 3 consecutive journeys then:
●an OBD stored fault is raised,
●the OBD fault warning light receives a request to be lit continuously. This request is only recognised if the
fault in question is authorised to activate the OBD warning light.
To deactivate the warning light, no OBD faults should be detected for 3 consecutive journeys.
The electrical fault finding checks taken into consideration by the OBD faults manager are as follows:
– pressure,
– turbocharging pressure,
– coolant temperature,
– air temperature
– upstream sensor,
– downstream sensor,
– upstream sensor heating,
– downstream sensor heating,
–injector1,
–injector2,
–injector3,
–injector4,– ignition coil 1,
– ignition coil 2,
– ignition coil 3,
– ignition coil 4,
– petrol pump,
– wastegate,
– canister bleed,
– air line system,
– turbocharging system
– pinking sensor,
– camshaft dephaser.
Page 31 of 230
PETROL INJECTION
Fault finding - Fault summary table
17B
17B-31
PETROL INJECTION
Fault finding - Fault summary table
17B
17B-31V9 MR-372-J84-17B050$282.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
Tool faultAssociated
DTC codeDescriptionLevel 2 fault
warning light
(Red brake
warning light)Level 1 fault
warning light
(Orange
injection
warning light)No warning
light onOBD
warning light
DF079 0638Motorised throttle
valve automatic
control2.DEF/
3.DEF/
4.DEF/CO/
6.DEF1.DEF/5.DEF/
7.DEF/8.DEF
DF080 0010Camshaft
dephaser circuitCO/CC.0/
CC.1/1.DEF/
2.DEF/3.DEF/
4.DEF/5.DEF
DF081 0443Canister bleed
solenoid valve
circuitCC.O/1.DEF CO/ CC.1
DF084 0685Actuator relay
control circuitCO/CC.0
CC.1
DF085 0627Fuel pump relay
control circuitCO/CC.0
CC.1/1.DEF
DF088 0325Pinking sensor
circuit1.DEF/2.DEF
DF089 0105Inlet manifold
pressure sensor
circuit1.DEF
2.DEF
3.DEF1.DEF
2.DEF
3.DEF
DF091 0500Vehicle speed
signal1.DEF/2.DEF
DF092 0130Upstream oxygen
sensor circuitCO.0
CC.1/1.DEF
2.DEF
DF093 0136Downstream
oxygen sensor
circuitCO.0
CC.1/1.DEF
DF095 0120Throttle
potentiometer
circuit gang 1CO.0/CC.1
1.DEF/2.DEF
DF096 0220Throttle
potentiometer
circuit track 2CO.0/ CC.1
DF099 C101Automatic gearbox
or sequential
gearbox
connection via the
multiplex network1.DEF/2.DEF/
3.DEF/4.DEF
DF101 C122ESP multiplex
connection1.DEF
Page 33 of 230
PETROL INJECTION
Fault finding - Fault summary table
17B
17B-33
PETROL INJECTION
Fault finding - Fault summary table
17B
17B-33V9 MR-372-J84-17B050$282.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
Tool faultAssociated
DTC codeDescriptionLevel 2 fault
warning light
(Red brake
warning light)Level 1 fault
warning light
(Orange
injection
warning light)No warning
light onOBD
warning light
DF404 C302Automatic gearbox
or sequential
gearbox CAN
connection1.DEF/2.DEF/
3.DEF
DF410 C155Instrument panel
connection1.DEF
DF436 0300Detection of engine
misfiring1.DEF/
2.DEF
3.DEF
DF455 0460Low fuel level
signal1.DEF/2.DEF
DF457 0315 Flywheel target1.DEF/
2.DEF
DF570 2600COOLANT PUMP
RELAYCO/CC.0
CC.1
DF601 0135Upstream O
2
sensor heating
power circuitCO.0/CC.1
1.DEF
DF602 0141Downstream O
2
sensor heating
power circuitCO.0/CC.1
1.DEF
DF623 C315Closing brake
signal1.DEF
DF624 C111UPC multiplex
connection1.DEF
2.DEF
DF635 1301LPG cylinder 1
combustion misfire1.DEF
2.DEF
DF636 1302LPG cylinder 2
combustion misfire1.DEF
2.DEF
DF637 1303LPG cylinder 3
combustion misfire1.DEF
2.DEF
DF638 1304LPG cylinder 4
combustion misfire1.DEF
2.DEF
DF639 1300Combustion misfire
in LPG mode1.DEF
2.DEF
3.DEF
DF650 2299Accelerator pedal
position signal1.DEF
DF1070 0534 Cold loop
Page 51 of 230
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-51
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-51V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF059
PRESENT
OR
STOREDCOMBUSTION MISFIRES ON CYLINDER 1
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– ignition: DF361 Ignition coil circuit cylinders 1-4
DF362 Ignition coil circuit cylinders 2-3
– fuel supply circuit:
DF026 Injector control circuit cylinder 1,
DF027 Injector control circuit cylinder 2,
DF028 Injector control circuit cylinder 3,
DF029 Injector control circuit cylinder 4,
DF085 Fuel pump relay control circuit.
– engine flywheel signal: DF154 Flywheel signal sensor circuit
DF457 Flywheel target
Check whether there are other cylinders with a combustion misfire fault detected by the
tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (coolant temperature 75°C minimum),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
–OBD warning light illuminated.
1.DEF
NOTESSpecial note:
– As soon as the fault is detected, the injection is cut off on
the faulty cylinder(s) to limit the temperature increase in
the catalytic converter,
– if a fault is present, the OBD warning light flashes.
2.DEFSpecial note:
–the OBD warning light remains continuously lit.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF059/S3000_V54_DF059
Page 53 of 230
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-53
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-53V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF060
PRESENT
OR
STOREDCOMBUSTION MISFIRING ON CYLINDER 2
1.DEF: Programming of stops
2.DEF: Dephaser mechanically jammed
3.DEF: Servo-control fault
4.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– ignition: DF361 Ignition coil circuit cylinders 1-4
DF362 Ignition coil circuit cylinders 2-3
– fuel supply circuit:
DF026 Injector control circuit cylinder 1,
DF027 Injector control circuit cylinder 2,
DF028 Injector control circuit cylinder 3,
DF029 Injector control circuit cylinder 4,
DF085 Fuel pump relay control circuit.
– engine flywheel signal: DF154 Flywheel signal sensor circuit
DF457 Flywheel target
Check whether there are other cylinders with a combustion misfire fault detected by the
tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (coolant temperature 75°C minimum),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
–OBD warning light illuminated.
1.DEF
NOTESSpecial note:
– As soon as the fault is detected, the injection is cut off on
the faulty cylinder(s) to limit the temperature increase in
the catalytic converter,
– if a fault is present, the OBD warning light flashes.
2.DEFSpecial note:
–the OBD warning light remains continuously lit.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF060/S3000_V54_DF060
Page 55 of 230
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-55
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-55V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF061
PRESENT
OR
STOREDCOMBUSTION MISFIRING ON CYLINDER 3
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– ignition: DF361 Ignition coil circuit cylinders 1-4
DF362 Ignition coil circuit cylinders 2-3
– fuel supply circuit:
DF026 Injector control circuit cylinder 1,
DF027 Injector control circuit cylinder 2,
DF028 Injector control circuit cylinder 3,
DF029 Injector control circuit cylinder 4,
DF085 Fuel pump relay control circuit.
– engine flywheel signal: DF154 Flywheel signal sensor circuit
DF457 Flywheel target
Check whether there are other cylinders with a combustion misfire fault detected by the
tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (coolant temperature 75°C minimum),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
–OBD warning light illuminated.
1.DEF
NOTESSpecial note:
– As soon as the fault is detected, the injection is cut off on
the faulty cylinder(s) to limit the temperature increase in
the catalytic converter,
– if a fault is present, the OBD warning light flashes.
2.DEFSpecial note:
–the OBD warning light remains continuously lit.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF061/S3000_V54_DF061
Page 57 of 230
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-57
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-57V9 MR-372-J84-17B050$329.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF062
PRESENT
OR
STOREDCOMBUSTION MISFIRING ON CYLINDER 4
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– ignition: DF361 Ignition coil circuit cylinders 1-4
DF362 Ignition coil circuit cylinders 2-3
– fuel supply circuit:
DF026 Injector control circuit cylinder 1,
DF027 Injector control circuit cylinder 2,
DF028 Injector control circuit cylinder 3,
DF029 Injector control circuit cylinder 4,
DF085 Fuel pump relay control circuit.
– engine flywheel signal: DF154 Flywheel signal sensor circuit
DF457 Flywheel target
Check whether there are other cylinders with a combustion misfire fault detected by the
tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (coolant temperature 75°C minimum),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
–OBD warning light illuminated.
1.DEF
NOTESSpecial note:
– As soon as the fault is detected, the injection is cut off on
the faulty cylinder(s) to limit the temperature increase in
the catalytic converter,
– if a fault is present, the OBD warning light flashes.
2.DEFSpecial note:
–the OBD warning light remains continuously lit.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V4C_DF062/S3000_V54_DF062
Page 68 of 230
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-68
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-68V9 MR-372-J84-17B050$376.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF085
PRESENT
OR
STOREDFUEL PUMP RELAY CONTROL CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition is switched on or command AC079
Actuator static test is activated.
Special note:
–OBD warning light illuminated.
CO/CC.1: The vehicle stalls and restart impossible
CC.0: Risk of fire in the event of an accident: petrol leak.
Intermittent CO: Intermittent relay cut-off: risk of draining the battery.
If the relay does not click:
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the injection actuator relay connections.
Check the cleanliness and condition of the connections of the fuel pump relay connector.
Repair if necessary.
Disconnect connector MT1 of the Protection and Switching Unit.
Check the cleanliness and condition of its connections.
Use the "Universal bornier" to check the insulation and continuity on the following connection:
Computer, connectorC, track D1Protection and Switching Unit, connector MT1,
track 5
Repair if necessary.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF085/S3000_V54_DF085