Df102 RENAULT TWINGO 2009 2.G Electrical Equipment - Petrol Injection Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: TWINGO, Model: RENAULT TWINGO 2009 2.GPages: 348
Page 41 of 348
17B-41V7 MR-413-X44-17B000$120.mif
PETROL INJECTION
Fault finding – Fault summary table17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
* TA: Automatic Transmission
* TDB: Instrument panel
Tool faultAssociated
DTCDiagnostic tool title
DF089105Inletmanifold pressure sensor cir cuit
DF091500Vehicle speed signal
DF092130Upstream oxygen sensor circuit
DF093136Downstream oxygen sensor circuit
DF095120Th rottle potentiometer circuit gang1
DF096220Th rottle potentiometer circuit gang 2
DF099C101Automatic gearbox (BVA) or sequential gearbox (BVR) connection via
multiplex network
DF100C155TDB* multiplex connection
DF101C122ESP multiplex connection
DF1022502Signal: power sig.* available
DF106575Cruise control/Speed limiter selector switch on steering wheel
DF109313Low fuel level misfiring
DF119340Camshaft sensor signal (only for CLIO III or MODUS)
DF1261604Passenger compartment heating resistor (only for CLIO III or MODUS)
DF127703Brake switch no. 1 circuit
DF128571Brake switch 2 circuit
DF150830Clutch contact circuit
DF154335Flywheel signal sensor circuit
DF196225Pedal sensor circuit track 1
DF1982120Pedal sensor circuit track 2
DF228504Brake signal
DF232530Refrigerant pressure sensor circuit
DF2341335After-sales tooth signal sensor circuit
Page 114 of 348
17B-114V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF102
PRESENT
OR
STOREDALTERNATOR POWER SIGNAL AVAILABLE
1.DEF: Multiplex line connection fault
NOTESConditions for applying the fault finding procedure to stored faults
The fault is declared present when the ignition is switched on or with the engine running.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, check the insulation and continuity of the following connections:
For NEW TWINGO or E33:
●AP29 between components 120 and 1016,
●2N between components 645 and 103,
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
For Clio III and MODUS:
●AP between components 120 and 1337,
●2N between components 1337 and 103.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
SIM32_V44_DF102/SIM32_V4C_DF102/SIM32_V50_DF102/SIM32_V54_DF102
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.