air condition Seat Ibiza 2020 Directive 2014/53/EU Bluetooth
[x] Cancel search | Manufacturer: SEAT, Model Year: 2020, Model line: Ibiza, Model: Seat Ibiza 2020Pages: 406, PDF Size: 9.22 MB
Page 331 of 406

Page 20 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
5.7.5 Earthed accessible conductive parts ..................... : N/A
5.7.6 Requirements when touch current exceeds ES2
limits N/A
Protective conductor current (mA) ......................... : N/A
Instructional Safeguard ................................ .......... : N/A
5.7.7 Prospective touch voltage and touch current
associated with external circuits N/A
5.7.7.1 Touch current from coaxial cables N/A
5.7.7.2 Prospective touch voltage and touch current
associated with paired conductor cables N/A
5.7.8 Summation of touch currents from external circ uits N/A
a) Equipment connected to earthed external
circuits, current (mA) ................................ ............. : N/A
b) Equipment connected to unearthed external
circuits, current (mA) ................................ ............. : N/A
5.8 Backfeed safeguard in battery backed up supplies
N/ A
Mains terminal ES ................................ ..................... : No battery bac ked up supplies N/ A
Air gap (mm) ................................ .............................. : N/ A
6 ELECTRICALLY - CAUSED FIRE
P
6.2 Classification of PS and PIS
P
6.2.2 Power source circuit classifications .......................... : (See appended table 6.2.2) P
6.2.3 Classification of potential ignition sources P
6.2.3.1 Arcing PIS ................................ ................................ : Open circuit voltage does not
exceed 50 V N/A
6.2.3.2 Resistive PIS ................................ ............................ : (See appended table 6.2.3.2) P
6.3 Safeguards against fire under normal operating and abnormal operating
conditions P
6.3.1 No ignition and attainable temperature value less
than 90 % defined by ISO 871 or less than 300 C
for unknown materials ................................ ........... : No ignition and no such
temperature attained within
the equipment P
Combustible materials outside fire enclosure .......... : Min. HB P
6.4 Safeguards against fire under single fault conditi ons
P
6.4.1 Safeguard method Control fire spread P
6.4.2 Reduction of the likelihood of ignition under single
fault conditions in PS1 circuits N/A
Page 352 of 406

Page 41 of 88 Report No. : 60404490 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
d) O vercurrent protective device limited output N/A
e) IC current limiter complying with G.9 N/A
Q.1.2 Test method and compliance ................................ : (See appended table Q.1) P
Current rating of overcurrent protective device (A)
................................ ................................ ............... : N/A
Q.2 Test for external circuits – paired conductor
cable N/A
Maximum output current (A) ................................ . : N/A
Current limiting method ................................ ......... :
R LIMITED SHORT CIRCUIT TEST
N/A
R.1 General
N/A
R.2 Test setup
N/A
Overcurrent protective device for test ................... :
R.3 Test method
N/A
Cord/cable use d for test ................................ ........ :
R.4 Compliance
N/A
S TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
S.1 Flammability test for fire enclosures and fire barrier materials of equipment
where the steady state power does not exceed 4 000 W N/A
Samples, material ................................ .................. :
Wall th ickness (mm) ................................ .............. :
Conditioning ( C) ................................ ................... :
Test flame according to IEC 60695 - 11 - 5 with
conditions as set out N/A
- Material not consumed completely N/A
- Material extinguishes within 30s N/A
- No burning of layer or wrapping tissue N/A
S.2 Fla mmability test for fire enclosure and fire barrier integrity
N/A
Samples, material ................................ .................. :
Wall thickness (mm) ................................ .............. :
Conditioning ( C) ................................ ................... :
S.3 Flammability test for the bottom of a fire enclosure
N/A
S.3.1 Mounting of samples N/A
S.3.2 Test method and compliance N/A