phone Seat Ibiza 2020 Directive 2014/53/EU Bluetooth
[x] Cancel search | Manufacturer: SEAT, Model Year: 2020, Model line: Ibiza, Model: Seat Ibiza 2020Pages: 406, PDF Size: 9.22 MB
Page 384 of 406

Page 73 of 88 Report No. : 60404490 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
known by other means such as setting or automatic
detection, the L Aeq , T acoustic output shall be ≤ 80 dB
when playing the fixed “programme simulation
noise” described in EN 50332 - 1.
– for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that
allows connection to a listening device for general
use, the unweighted r.m.s. output voltage shall be ≤
15 mV (analogue interface) or - 30 dBFS (digital
interface) w hen playing the fixed “programme
simulation noise” described in EN 50332 - 1.
10.6.3.3 RS2 limits (new)
RS2 is a class 2 acoustic energy source that does
not exceed the following:
– for equipment provided as a package (player with
its listening device ), and with a proprietary connector
between the player and its listening device, or where
the combination of player and listening device is
known by other means such as setting or automatic
detection, the weekly sound exposure level, as
described in EN 503 32 - 3, shall be ≤ 80 dB when
playing the fixed "programme simulation noise"
described in EN 50332 - 1.
– for equipment provided with a standardized
connector (for example, a 3,5 phone jack) that
allows connection to a listening device for general
use, the unw eighted r.m.s. output level, integrated
over one week, as described in EN50332 - 3, shall be
≤ 15 mV (analogue interface) or - 30 dBFS (digital
interface) when playing the fixed “programme
simulation noise” described in EN 50332 - 1. N/A
10.6.4
Requirements f or maximum sound exposure
N/A
10.6.4.1 Measurement methods
All volume controls shall be turned to maximum
during tests.
Measurements shall be made in accordance with EN
50332 - 1 or EN 50332 - 2 as applicable. N/A
10.6.4.2 Protection of persons
Except as given below, protection requirements for
parts accessible to ordinary persons , instructed
persons and skilled persons are given in 4.3.
NOTE 1 Volume control is not considered a safeguard.
Between RS2 and an ordinary person , the basic
safeguard may be r eplaced by an instructional
safeguard in accordance with Clause F.5, except
that the instructional safeguard shall be placed on
the equipment, or on the packaging, or in the
instruction manual. N/A
Page 386 of 406

Page 75 of 88 Report No. : 60404490 001
IEC 62368 - 1_ATTACHMENT 2
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
are offered, an administrator (for example, parental
restrictions, business/educational administrators,
etc.) shall be able to lock any optional settings into a
specific configuration.
The personal music player shall be supplied with
easy to understand explanation to the user of the
dose management system, the risks involved, and
how to use the system safely. The user shall be
ma de aware that other sources may significantly
contribute to their sound exposure, for example
work, transportation, concerts, clubs, cinema, car
races, etc.
10.6.5.2 Dose - based warning and requirements
When a dose of 100 % CSD is reached, and at lea st
at every 100 % further increase of CSD , the device
shall warn the user and require an
acknowledgement. In case the user does not
acknowledge, the output level shall automatically
decrease to compliance with class RS1.
The warning shall at least clearly indicate that
listening above 100 % CSD leads to the risk of
hearing damage or loss. N/A
10.6.5.3 Exposure - based requirements
With only dose - based requirements, cause and
effect could be far separated in time, defying the
purpose of educating users abo ut safe listening
practice. In addition to dose - based requirements, a
PMP shall therefore also put a limit to the short - term
sound level a user can listen at.
The exposure - based limiter (EL) shall automatically
reduce the sound level not to exceed 100 dB (A) or
150 mV integrated over the past 180 s, based on
methodology defined in EN 50332 - 3.
The EL settling time (time from starting level
reduction to reaching target output) shall be 10 s or
faster.
Test of EL functionality is conducted according to
EN 50 332 - 3, using the limits from this clause. For
equipment provided as a package (player with its
listening device), the level integrated over 180 s
shall be 100 dB or lower. For equipment provided
with a standardized connector, the unweighted level
integrate d over 180 s shall be no more than 150 mV
for an analogue interface and no more than - 10
dBFS for a digital interface.
NOTE In case the source is known not to be music (or test
signal), the EL may be disabled. N/A
10.6.6
Requirements for listening devic es (headphones, earphones, etc.)
N/A