charging SUZUKI SWIFT 2000 1.G RG413 Service Owner's Manual

SUZUKI SWIFT 2000 1.G RG413 Service Owner's Manual SWIFT 2000 1.G SUZUKI SUZUKI https://www.carmanualsonline.info/img/20/7606/w960_7606-0.png SUZUKI SWIFT 2000 1.G RG413 Service Owner's Manual

Page 683 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual CHARGING SYSTEM 6H-3
CARE OF BATTERY
1) The battery is a very reliable component, but needs periodical attentions.
Keep the battery carrier clean
Prevent rust formation on the terminal posts
Keep t

Page 684 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual 6H-4 CHARGING SYSTEM
GENERATOR
The generator is a small and high performance type with an IC regulator incorporated.
The internal components are connected electrically as shown below figure.
The gener

Page 685 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual CHARGING SYSTEM 6H-5
DIAGNOSIS
BATTERY
VISUAL INSPECTION
Check for obvious damage, such as cracked or broken case or cover, that could permit loss of electrolyte. If
obvious damage is noted, replace b

Page 686 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual 6H-6 CHARGING SYSTEM
GENERATOR
Trouble in charging system will show up as one or more of the fol-
lowing conditions:
1) Faulty indicator lamp operation.
2) An undercharged battery as evidenced by slow

Page 687 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual CHARGING SYSTEM 6H-7
UNDERCHARGED BATTERY
This condition, as evidenced by slow cranking or indicator clear
with red dot can be caused by one or more of the following condi-
tions even though indicator

Page 688 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual 6H-8 CHARGING SYSTEM
3) Ground F terminal and start engine, then measure voltage at
B terminal as shown in left figure.
Voltage is higher than standard value
It is considered that generator itself is

Page 689 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual CHARGING SYSTEM 6H-9
ON-VEHICLE SERVICE
BATTERY
JUMP STARTING IN CASE OF EMERGENCY
WITH AUXILIARY (BOOSTER) BATTERY
Both booster and discharged battery should be treated carefully when using jumper ca

Page 690 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual 6H-10 CHARGING SYSTEM
DISMOUNTING
1) Disconnect negative cable (1).
2) Disconnect positive cable (2).
3) Remove retainer (3).
4) Remove battery (4).
HANDLING
When handling battery, following safety pr

Page 691 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual CHARGING SYSTEM 6H-11
DISMOUNTING AND REMOUNTING
DISASSEMBLY AND REASSEMBLY
1.“B” terminal wire 3. Generator bolt 5. Splash cover (Right) Tightening torque
2.“B” terminal nut 4. Generator belt

Page 692 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Owners Manual 6H-12 CHARGING SYSTEM
INSPECTION
ROTOR
1) Using ohmmeter, check for continuity between slip rings of
rotor. If there is no continuity, replace rotor.