050TJ±13
05±1094
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
DIAGNOSTIC TROUBLE CODE CHART
If malfunction code is displayed during the DTC check (sensor check), ch\
eck the circuit listed for the code
in the table below (Proceed to the page given for that circuit).
DTC No.
(See Page)Detection ItemTrouble AreaMemory
00Normal±±
11 *1
(05±1102)
Room temperature sensor circuit
(open/short) Cooler thermistor (room temp. sensor)
Harness or connector between cooler thermistor (room
temp. sensor) and A/C amplifier assy
A/C amplifier assy
(8.5 min. or more)
12 *2
Ambient temperature sensor circuit
(open/short) Thermistor assy (ambient temp. sensor)
Harness or connector between thermistor assy (ambient
temp. sensor) and combination meter
Combination meter12
(05±1106) Combination meter
Harness or connector between combination meter and A/C
amplifier assy
A/C amplifier assy
(8.5 min. or more)
13
(05±1109)
Evaporator temperature sensor circuit
(open/short) Cooler thermistor No.1 (evaporator temp. sensor)
Harness or connector between cooler thermistor No.1
(evaporator temp. sensor) and A/C amplifier assy
A/C amplifier assy
(8.5 min. or more)
21 *3
Solar sensor circuit (open) (Passenger
side) Automatic light control sensor (solar sensor)
Harness or connector between automatic light control sen-
( l ) d A/C lifi
(8.5 min. or more)
21
(05±1113)
Solar sensor circuit (short) (Passenger
side)sor (solar sensor) and A/C amplifier assy
A/C amplifier assy
±
23
(05±1116)
Pressure sensor circuit A/C tube assy (pressure sensor)
Harness or connector between A/C tube assy (pressure
sensor) and A/C amplifier assy
A/C amplifier assy
±
24 *3
Solar sensor circuit (open)
(Driver side)Automatic light control sensor (solar sensor)
Harness or connector between automatic light control sen-
( l ) d A/C lifi
(8.5 min. or more)
24
(05±1119)
Solar sensor circuit (short)
(Driver side)sor (solar sensor) and A/C amplifier assy
A/C amplifier assy
±
31
(05±1122)
Air mix damper position sensor circuit
(Passenger side) Air mix damper servo sub±assy (air mix damper position
sensor)
Harness or connector between air mix damper servo sub±
assy (air mix damper position sensor) and A/C amplifier
assy
A/C amplifier assy
(1 min. or more)
33
(05±1126)
Air outlet damper position sensor circuit Mode damper servo sub±assy (mode damper position sen-
sor)
Harness or connector between mode damper servo sub±
assy (mode damper position sensor) and A/C amplifier assy
A/C amplifier assy
(1 min. or more)
36
(05±1129)
Air mix damper position sensor circuit
(Driver side) Air mix damper servo sub±assy (Air mix damper position
sensor)
Harness or connector between air mix damper servo sub±
assy (air mix damper position sensor) and A/C amplifier
assy
A/C amplifier assy
(1 min. or more)
41
(05±1133)
Air mix damper control servomotor
(Passenger side) Air mix damper servo sub±assy (air mix damper control)
Harness or connector between air mix damper servo sub±
assy (air mix damper control) and A/C amplifier assy
A/C amplifier assy
(15 sec.)
Page 1111 of 5135
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
05±1095
AVENSIS REPAIR MANUAL (RM1018E)43
(05±1136)
Air outlet damper control servomotor Mode damper servo sub±assy (mode damper control)
Harness or connector between mode damper servo sub±
assy (mode damper control) and A/C amplifier assy
A/C amplifier assy
(15 sec.)
46
(05±1139)
Air mix damper control servomotor
(Driver side) Air mix damper servo sub±assy (air mix damper control )
Harness or connector between air mix damper servo sub±
assy (air mix damper control servomotor) and A/C amplifier
A/C amplifier assy
(15 sec.)
HINT:
*1: If the room temp. is approx. ±18.6 C (±3.7 F) or lower, DTC 11 may be output even though the sys-
tem is normal.
*2: If the ambient temp. is approx. ±52.9 C (±61.4 F) or lower, DTC may be output even though the
system is normal.
*3: If the check is being performed in a dark place, DTC 21 and 24 (solar \
sensor circuit abnormal) could
be displayed.
Page 1114 of 5135
I36146
Display code R/FDEFLHD:
I36147
Display code RHD:R/FDEF
Blower level Step No.Display
codeConditions
Air flow bent Air inlet damper Compressor
ºCOOLº side (Full closed)Air mix damper
OFF FRESH
FACE 0
1
2
3
6
7
8
9
104
51
16
16
16
16
16
16
16
31 0
1
2
3
6
7
8 4
5
9FACE
FACE
FACE
B/L
FOOT1
FOOT/ DEF.
DEF.FRESH
ON
ON
ON
ON
ON
ON
ONºCOOLº side (Full closed)
ºCOOLº side (Full closed)
ºCOOLº side (Full closed)
ºCOOLº/ ºHOT º (50 % open)
ºHOTº side (Full opened)
FOOT FACE1FRESH
FRESH
RECIRCULATION
RECIRCULATION
RECIRCULATION
RECIRCULATION
RECIRCULATION
RECIRCULATIONHot gas magnetic valve
ºCOOLº/ ºHOT º (50 % open)
ºHOTº side (Full opened)
ºHOTº side (Full opened)ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF OFF
ºHOTº side (Full opened) OFF
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1093
AVENSIS REPAIR MANUAL (RM1018E)
6. ACTUATOR CHECK
(a) After entering the DTC check mode (Sensor Check
Mode) press the R/F switch.
(b) Since each damper, motor and relay automatically oper-
ates at 1 second intervals beginning in order from 10 in
the temperature display, check the temperature and air
flow from visual and by hand.
If the slower display is desired, press the DEF switch and
change it to step operation. Each time the DEF switch is
pressed, the display changes by 1 step.
HINT:
Codes are displayed from the smaller to the larger num-
bers in order.
To cancel the check mode, press the OFF switch.
Page 1140 of 5135
I35378
A23
Air Mix Control Servo Motor (Driver Side) A/C Control Assembly
M
MAX
HOT4P±L
A15 AMDH12
MAX
COOL5B
A15 AMDC11
PT 3GR
A16 TPD8
VZ 2Y±B
A16 S5±22
GND 1Y±R
A15 SG±214
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1139
AVENSIS REPAIR MANUAL (RM1018E)
DTC 46 AIR MIX DAMPER CONTROL SERVOMOTOR
CIRCUIT (DRIVER SIDE)
CIRCUIT DESCRIPTION
The air mix damper servo sub±assy is controlled by the A/C amplifier and moves the air mix damper to the
desired position.
DTC No.Detection ItemTrouble Area
46Air mix damper position sensor value does not change even if
A/C amplifier operated air mix damper control servomotor.
Air mix damper servo sub±assy (air mix damper control )
Harness or connector between air mix damper servo sub±
assy (air mix damper control servomotor) and A/C amplifier
A/C amplifier assy
WIRING DIAGRAM
05A8A±02
Page 1141 of 5135
05±1140
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
1PERFORM ACTUATOR CHECK
(a)Set the actuator check mode (See page 05±1091).
(b) Press the DEF switch (driver side) and change to the step operation.
(c) Check the air flow temperature by hand.
Display CodeAir Mix Damper Operation
0COOL side (0 % open)
1COOL side (0 % open)
2COOL side (0 % open)
3COOL side (0 % open)
4COOL/HOT (50% open)
5COOL/HOT (50% open)
6HOT side (100% open)
7HOT side (100% open)
8HOT side (100% open)
9HOT side (100% open)
NG PROCEED TO NEXT CIRCUIT INSPECTION SHOWN ON PROBLEM SYMPTOMS TABLE
OK
Page 1142 of 5135
I35383
RHD Models:
MAX. COOL MAX. HOT
1
2
3
4
5
MAX HOTMAX COOL
I36141
LHD Models:
MAX. COOL MAX. HOT
MAX HOTMAX COOL
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
05±1141
AVENSIS REPAIR MANUAL (RM1018E)
2INSPECT AIRMIX DAMPER SERVO SUB±ASSY
(a)Remove the air mix damper servo sub±assy.
(b)Connect the positive (+) lead from the battery to terminal
MAX HOT and negative (±) lead to terminal MAX COOL,
then check that the lever turns to ºHOTº side smoothly.
(c)Connect the positive (+) lead from the battery to terminal MAX COOL and negative (±) lead to terminal MAX HOT,
then check that the lever turns to ºCOOLº side smoothly.
NGREPLACE AIRMIX DAMPER SERVO SUB±ASSY
OK
3CHECK HARNESS AND CONNECTOR(AIRMIX DAMPER SERVO SUB±ASSY ± A/C AMPLIFIER)
(a)Check for an open or short circuit in harness and connector between air mix c\
ontrol servomotor and
A/C amplifier (See page 01±32).
NG REPAIR OR REPLACE HARNESS ORCONNECTOR
OK
REPLACE AIR CONDITIONING AMPLIFIER
Page 1146 of 5135
I35377
A24
Air Mix Control Servo Motor (Front Passenger Side) A/C Control Assembly
MA15 AMPH W
(*1)
W
(*2) W
(*2)5
IQ1 MAX 4 (*1)
HOT 5 (*2)
A15 AMPC Y
(*1)
Y
(*2) Y
(*2)4
IQ1 MAX 5 (*1)
COOL 4 (*2)2
1
A16 TPP V
(*1)
V
(*2) V
(*2)3
IQ1 PT20
3
A16 S5±1 R
(*1)
R
(*2) R
(*2)1
IQ1 VZ 2 (*1)
1 (*2)1
A15 SG±1 P
(*1)
P
(*2) P
(*2)2
IQ1 GND
1 (*1)
2 (*2)13
*1: LHD
*2: RHD
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1133
AVENSIS REPAIR MANUAL (RM1018E)
DTC 41 AIR MIX DAMPER CONTROL SERVOMOTOR
CIRCUIT(PASSENGER SIDE)
CIRCUIT DESCRIPTION
This air mix damper servo sub±assy is controlled by the A/C amplifier and moves the air mix damper to the
desired position.
DTC No.Detection ItemTrouble Area
41Air mix damper position sensor value does not change even if
A/C amplifier operated air mix damper control servomotor.
Air mix damper servo sub±assy (air mix damper control)
Harness or connector between air mix damper servo sub±
assy (air mix damper control) and A/C amplifier assy
A/C amplifier assy
WIRING DIAGRAM
05A83±02
Page 1147 of 5135
05±1134
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
AVENSIS REPAIR MANUAL (RM1018E)
INSPECTION PROCEDURE
1PERFORM ACTUATOR CHECK
(a)Set the actuator check mode (See page 05±1091).
(b) Press the DEF switch (passenger side) and change to step operation.
(c) Check the air flow temperature by hand.
Display CodeAir Mix Damper Operation
0COOL side (0% open)
1COOL side (0% open)
2COOL side (0% open)
3COOL side (0% open)
4COOL/HOT (50% open)
5COOL/HOT (50% open)
6HOT side (100% open)
7HOT side (100% open)
8HOT side (100% open)
9HOT side (100% open)
OK PROCEED TO NEXT CIRCUIT INSPECTION SHOWN ON PROBLEM SYMPTOMS TABLE
NG
Page 1148 of 5135
I35383
LHD Models:
MAX. COOL MAX. HOT
1
2
3
4
5
MAX HOTMAX COOL
I36141
LHD Models:
MAX. COOL MAX. HOT
MAX HOTMAX COOL
±
DIAGNOSTICS AIR CONDITIONING SYSTEM
05±1135
AVENSIS REPAIR MANUAL (RM1018E)
2INSPECT AIRMIX NO.2 DAMPER SERVO SUB±ASSY
(a)Remove the air mix damper servo sub±assy.
(b)Connect the positive (+) lead from the battery to terminal
MAX HOT and negative (±) lead to terminal MAX COOL,
then check that the lever turns to ºHOTº side smoothly.
(c)Connect the positive (+) lead from the battery to terminal MAX COOL and negative (±) lead to terminal MAX HOT,
then check that the lever turns to ºCOOLº side smoothly.
NGREPLACE AIRMIX NO.2 DAMPER SERVO SUB±ASSY
OK
3CHECK HARNESS AND CONNECTOR(AIRMIX DAMPER NO.2 SERVO SUB±ASSY ± A/C AMPLIFIER)
(a)Check for an open or short circuit in harness and connector between air mix d\
amper control servomotor
and A/C amplifier (See page 01±32).
NG REPAIR OR REPLACE HARNESS ORCONNECTOR
OK
REPLACE AIR CONDITIONING AMPLIFIER
Page 1149 of 5135
4(V)
1
0
100%
TPI terminal voltage
Damper opening angle
I35378
A23
Air Mix Control Servo Motor (Driver Side) A/C Control Assembly
M
MAX
HOT4P±L
A15 AMDH12
MAX
COOL5B
A15 AMDC11
PT 3GR
A16 TPD8
VZ 2Y±B
A16 S5±22
GND 1Y±R
A15 SG±214
± DIAGNOSTICSAIR CONDITIONING SYSTEM
05±1129
AVENSIS REPAIR MANUAL (RM1018E)
DTC 36 AIR MIX DAMPER POSITION SENSOR
CIRCUIT (DRIVER SIDE)
CIRCUIT DESCRIPTION
This sensor detects the position of the air mix damper and
sends the appropriate signals to the A/C amplifier. The position
sensor is built in the air mix damper servo sub±assy.
DTC No.Detection ItemTrouble Area
36Short to ground or power source circuit in air mix damper posi-
tion sensor circuit.
Air mix damper servo sub±assy (Air mix damper position
sensor)
Harness or connector between air mix damper servo sub±
assy (air mix damper position sensor) and A/C amplifier assy
A/C amplifier assy
WIRING DIAGRAM
05A80±02