relay AUDI A4 1995 B5 / 1.G APB Engine Secondary Air System User Guide
Page 24 of 29
26-51
      
Check voltage supply of the Secondary Air 
Injection (AIR) pump motor  
     
-  Remove connector for Secondary Air Injection 
(AIR) pump motor -V101-. 
     
-  Connect VAG 1527B voltage tester between 
terminals 1 and 2 
     
-  Initiate output Diagnostic Test Mode (DTM) and 
activate Secondary Air Injection (AIR) pump 
relay -J299-. 
     
       Repair Manual, 2.7 Liter V6 5V BiTurbo Fuel 
Injection & Ignition, Engine Code(s): APB, Repair Group 01
   
     
 
LED must blink
Pa
ge 24 of 29 Secondar
y air s
ystem
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE05.26.2 
Page 25 of 29
26-52
       If LED does not blink:  
     
-  Perform following tests marked with dots:
     
Check wire connection from connector at 
Secondary Air Injection (AIR) pump motor-
V101- to Secondary Air Injection (AIR) pump 
relay -J299- (in 3-socket relay carrier in E-
Box, plenum chamber, position 2) for open 
circuit. 
     
       Electrical Wiring Diagrams, Troubleshooting & 
Component Locations   
     
Check wire connection from connector at 
Secondary Air Injection (AIR) pump motor -
V101- to Ground (GND) connection 1 in 
engine compartment wiring harness for open 
circuit: 
     
       Electrical Wiring Diagrams, Troubleshooting & 
Component Locations   
      If no malfunctions are detected:  
     
-  Replace Secondary Air Injection (AIR) pump 
motor -V101-. 
Pa
ge 25 of 29 Secondar
y air s
ystem
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE05.26.2