heater AUDI A4 1995 B5 / 1.G ATW Engine Readiness Code Workshop Manual
Page 19 of 35
01-81
Display fields
1 2 3 4
Display group 030: Oxygen sensor status
Display
X X X
X X X
Indicated
Oxygen sensor status, bank 1, sensor 1
Oxygen sensor status, bank 2, sensor 1
Functional range
0 = off
1 = on 0 = off
1 = on
Specified value
1 1 1
1 1 0
Significance of 3 digit indications in display group 030 X
X
X
Display fields 1 and 2
X Oxygen sensor control: 0= not active; 1 = active
X Operational readiness of oxygen sensor: 0= not active; 1 = active
X Condition of oxygen sensor heater: 0= not active; 1 = active
Note:
The first position of the 3 digit indication (heating) fluctuates between 0 and 1 at certain operation points.
Oxygen sensor control of oxygen sensor behind catalytic converter (bank 1, sensor 2) is not active without engine load,
meaning that the third position of the 3-digit display is 0.
-
Do not start test until indication in display field 1
Pa
ge 19 of 35 Readiness code11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.01.8