oil AUDI A4 1995 B5 / 1.G Instrument Cluster OBD From Model Year 2000 User Guide

Page 70 of 99

01-134
Adaptation table: Adaptation channel
Adaptation function
02 Resetting SRI after service Page 01
-136

03 Adaptation of fuel gauge Page 01
-140

04 Language version of driver information display Page 01
-143

09 Odometer Page 01
-148

18 Adaptation of auxiliary heater Page 01
-152

30 Adaptation of fuel gauge sender resistance range Page 01
-155

35 Adaptation of engine speed threshold Page 01
-158

40 Adaptation for distance driven since service Page 01
-161

41 Adaptation for time since service Page 01
-164

42 Adaptation for minimum mileage performance Page 01
-167

43 Adaptation for maximum mileage performance Page 01
-170

44 Adaptation for maximum time interval Page 01
-173

45 Adaptation for oil quality Page 01
-176

46 Adaptation for total consumption quantity (only gasoline engines) Page 01
-179

60 Adaptation powertrain data-BUS Page 01
-181

61 Adaptation comfort system data-BUS Page 01
-185

62 Adaptation information data-BUS Page 01
-188

Pa
ge 70 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 95 of 99

01-158

Adaptation of the engine speed threshold
This function is used to adapt the offset value for
the engine speed threshold to the dynamic oil
pressure warning. Rapid data transfer
HELP
Select function XX

Indicated on display
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
10 - Adaptation

Indicated on display
- Press -Q- button to confirm input.
Adaptation Input channel number XX

Indicated on display:
- Press buttons -3- and 5-.
- Press -Q- button to confirm input.
Pa
ge 95 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 96 of 99

01-159

Channel 35 Adaptation 0
- 1 3-

Indicated on display: Adaptation value is displayed, for example 0.
Notes:
The adaptation value of 0 corresponds to the value set at the factory
for the oil pressure warning if the oil pressure drops below 1.2 bar at
1500 rpm. The adaptation can be performed in four steps (0-1000).The adaptation value of "250" changes the engine speed threshold to
1750 rpm. If the value "0" was changed due to a customer complaint, the
changed value must be transferred when replacing instrument cluster.
-
Press button.
Channel 35 Adaptation 0 Input adaptation value XXXXX

Indicated on display:
- Input adaptation value using keypad, filling initial positions with "0", for
example, 00250.
Channel 35 Adaptation 0
Q
Input adaptation value 00250

Indicated on display:
- Press -Q- button to confirm input.
Pa
ge 96 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2