15-94
      
Test requirements:  
     
Vehicle diagnostic, testing and information 
system VAS 5051 or VAG 1551 Scan Tool 
connected 
     
Test sequence  
     
-  Initiate output Diagnostic Test Mode (DTM) and 
activate solenoid valve for camshaft adjuster. 
Output Diagnostic Test Mode Camshaft timing control
    
Display  
If the valve is not actuated (does not click).  
Checking internal resistance  
This valve is actuated (clicks) for approx. one minute if the operation is 
not switched to the next component by pressing the   key. 
-  Check internal resistance of solenoid valve for camshaft adjuster.
-  Switch ignition off.
    
-  Disconnect connector -arrow- from camshaft adjuster.