fuel AUDI A4 1997 B5 / 1.G AFC Engine Cold Start Driveability Problems Workshop Manual
Page 3 of 4
24-44
      
CAUTION! 
     
Use a second technician to operate the VAG 
1551 scan tool. 
     
-  Start engine (without previously switching 
ignition off), drive and record voltage signal 
(display field 3 shows bank 1; display field 4 
shows bank 2). 
     
When oxygen sensor control starts, the voltage 
signal fluctuates between 0.0 and 0.9 volts (the 
voltage signals of both banks do not need to be 
synchronous with one another). 
     If driveability difficulties occur before the start of 
oxygen sensor control, oxygen sensor control 
can not be the cause of the problem. 
     If driveability difficulties occur after the start of 
oxygen sensor control, check function of heated 
oxygen sensor   page 24
-45
 . 
     
If driveability improves after the start of closed-
loop oxygen sensor control, the cause (e.g. air 
leak, faulty fuel injector) works against the 
improvement by interrupting control. This can 
be recognized by reading the oxygen sensor 
learned values   Repair Group 01, "Read 
Measuring Value Block" function 08, display 
Pa