19-9
      
-  Close drain plug at engine block and at bottom 
left of radiator. 
     
-  Push on connection flange of coolant hose at 
bottom of radiator, and install locking element for 
connection flange. 
    
-  Unscrew cap on expansion tank, screw on adapter VAG 1274/1, and 
extend with 42mm diameter and 100 mm long auxiliary hose. 
    
-  Open hose clamp, pull back coolant hose sufficiently so that vent hole 
is no longer concealed by connection. 
-  Open bleed screw at coolant pipe below expansion tank.
-  Pour coolant into system until it flows out at bleeder hole, then tighten 
screw to 15 Nm (11 ft lb). 
-  Pour in more coolant until it flows out at vent hole, then push on 
coolant hose and tighten. 
-  Close cap on expansion tank and set heater controls to hot position.
-  Start engine and run at about 2000 RPM for about 3 minutes.
Pa