sensor AUDI A4 1997 B5 / 1.G ATQ Engine Oxygen Sensor Control Checking
Page 61 of 63
24-125
       If no malfunctions are found in wires:  
     
-  Replace appropriate Oxygen Sensor (O2S).
     
- Read readiness code   Page 01
-78
 . If DTC 
memory was erased, readiness code must be 
re-generated  Page 01
-82
 . 
Pa
ge 61 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
Page 62 of 63
24-126
      
Oxygen sensor, removing and installing
 
     
Special tools and equipment  
    
Removing  
Component location of harness connectors   Overview of component 
locations, page   Page 24
-5   
3337 wrench, 7-piece set Locking compound G 052 112 A3
-  Disconnect 4-pin harness connector leading to respective oxygen 
sensor. 
-  Open cable ties.
-  Unscrew oxygen sensor using special tool 3337.
Pa
ge 62 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
Page 63 of 63
24-127
      
Installing  
      Note the following when installing:  
     
Notes:  
     
Oxygen sensor threads are coated with an 
assembly paste. This paste must not contact 
sensor openings. 
     Cable ties must always be installed again in 
exactly the same place to prevent the sensor 
wire from contacting the exhaust pipe. 
     Tightening torque: 55 Nm
Pa
ge 63 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3