01-154

Channel 18 Adaptation 1
Q
- 1 3-

Indicated on display:
- Press -Q- button to confirm input.
Channel 18 Adaptation 1
Q
Store changed value?

Indicated on display:
- Press -Q- button to confirm input.
Channel 18 Adaptation 1 Changed value is stored

Indicated on display:
-
End adaptation of the auxiliary heater by pressing the button.
Pa
ge 91 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 92 of 99

01-155

Adaptation of fuel gauge sender resistance
range
This function is used to adjust the fuel gauge
sender resistance range if the fuel gauge display
in the instrument cluster does not match the
actual amount of fuel in the tank. Rapid data transfer
HELP
Select function XX

Indicated on display
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
10 - Adaptation

Indicated on display
- Press -Q- button to confirm input.
Adaptation Input channel number XX

Indicated on display:
- Press buttons -3- and -0-.
- Press -Q- button to confirm input.
Pa
ge 92 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 93 of 99

01-156

Channel 30 Adaptation 128 Tank sender - 1 3-

Indicated on display: Adaptation value is displayed, for example 128.
Notes:
"128" is the adaptation value for the standard resistance range for the
fuel gauge sender as set by the factory. The resistance value for the fuel gauge sender resistance range can
be adjusted by 8 Ohm to give an adaptation value between 120 and
136. If the value "128" was changed due to a customer complaint, the
changed value must be transferred when replacing instrument cluster.
-
Press button.
Channel 30 Adaptation 128 Input adaptation value XXXXX

Indicated on display:
Example:
Desired input value: 132
Keypad input: 00132 - Input desired correction value using scan tool keypad, filling initial
positions with "0" and watch how the display responds.
Channel 30 Adaptation 128
Q
Input adaptation value 00132

Indicated on display:
- Press -Q- button to confirm input.
Pa
ge 93 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 94 of 99

01-157

Channel 30 Adaptation 132
Q
Tank sender - 1 3-

Indicated on display:
- Press -Q- button to confirm input.
Channel 30 Adaptation 132
Q
Store changed value?

Indicated on display:
- Press -Q- button to confirm input.
Channel 30 Adaptation 132 Changed value is stored

Indicated on display:
- End adaptation of the fuel gauge sender resistance range by pressing
the button.
Pa
ge 94 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 95 of 99

01-158

Adaptation of the engine speed threshold
This function is used to adapt the offset value for
the engine speed threshold to the dynamic oil
pressure warning. Rapid data transfer
HELP
Select function XX

Indicated on display
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
10 - Adaptation

Indicated on display
- Press -Q- button to confirm input.
Adaptation Input channel number XX

Indicated on display:
- Press buttons -3- and 5-.
- Press -Q- button to confirm input.
Pa
ge 95 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 96 of 99

01-159

Channel 35 Adaptation 0
- 1 3-

Indicated on display: Adaptation value is displayed, for example 0.
Notes:
The adaptation value of 0 corresponds to the value set at the factory
for the oil pressure warning if the oil pressure drops below 1.2 bar at
1500 rpm. The adaptation can be performed in four steps (0-1000).The adaptation value of "250" changes the engine speed threshold to
1750 rpm. If the value "0" was changed due to a customer complaint, the
changed value must be transferred when replacing instrument cluster.
-
Press button.
Channel 35 Adaptation 0 Input adaptation value XXXXX

Indicated on display:
- Input adaptation value using keypad, filling initial positions with "0", for
example, 00250.
Channel 35 Adaptation 0
Q
Input adaptation value 00250

Indicated on display:
- Press -Q- button to confirm input.
Pa
ge 96 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 97 of 99

01-160

Channel 35 Adaptation 250
Q
- 1 3-

Indicated on display:
- Press -Q- button to confirm input.
Channel 35 Adaptation 250
Q
Store changed value?

Indicated on display:
- Press -Q- button to confirm input.
Channel 35 Adaptation 250 Changed value is stored

Indicated on display:
-
End adaptation of the engine speed threshold by pressing the
button.
Pa
ge 97 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 98 of 99

01-161

Distance driven since service
This function is used to input the distance in
miles since the last service. Rapid data transfer
HELP
Select function XX

Indicated on display
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
10 - Adaptation

Indicated on display
- Press -Q- button to confirm input.
Adaptation Input channel number XX

Indicated on display:
- Press buttons -4- and -0-.
- Press -Q- button to confirm input.
Channel 40 Adaptation 8 Actual value Insp. in 100 Miles - 1 3-

Indicated on display: The display indicates the number of miles driven
since the last service (here for example, 8 indicates 800 miles)
Pa
ge 98 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 99 of 99

01-162

Notes:

Input of current specified value is only possible
in units of 100 miles, therefore indication in
display also changes in 100 mile units.
Observe notes when replacing instrument
cluster Page 01
-191
.

Values can only be input directly using the scan
tool keypad.