19-23

- Replace O-ring on coolant drain screw and
screw drain screw back into engine.

Tightening torque: 20 Nm

- Install bottom coolant hose and secure.

- Close coolant drain tap on radiator.

- Screw adapter VAG 1274/8 onto expansion tank and insert extension
VAG 1274/10 into the adapter.

- Loosen coolant hose on heat exchanger and pull back hose far enough
so that bleeder hole in hose -arrow- is no longer covered by
connection.
- Fill up coolant until it comes out at bleeder hole in coolant hose.
- Push coolant hose onto connection and tighten.
Pa
ge 25 of 34 Coolin
g system com
ponents, removin
g and installin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE05.19.1

Page 27 of 34

19-25

- Start engine and let it idle for about 10
minutes.

- Maintain an engine speed of about 2000 RPM
for about 5 minutes.

- Allow engine to run at idling speed until bottom
hose on radiator becomes hot.

- Check coolant level and top up if necessary.
When engine is at normal operating temperature
coolant level must be on max. mark, and
between min. and max. marks when engine is
cold.

Note:
When the engine is hot the cooling system is
under pressure. Carefully open filler cap on
expansion tank to release pressure before
starting repair work.

WARNING!

Hot steam can escape from the expansion
tank when the filler cap is opened. Cover the
filler cap with a cloth and remove it carefully.