Display fields  
  
1   2   3  
4  
Display group 043: Oxygen sensor aging oxygen sensor behind catalytic converter (Bank 1)  
Display  xxxx/RPM  
xxx C  
x.xxx V  
Test ON  
Indicated  Engine speed 
(RPM)  Exhaust 
temperature  Voltage of oxygen sensor 
behind CAT, Bank 1  Diagnostic condition  
Work range   0 - 6800/RPM  
70 - 850  C  
0.000 - 1.000 Volt  
Test OFF  
Test ON  
B1-S2 OK  
B1-S2 not OK  
Specified 
value  1900 - 
2200/RPM  greater than 320 
C  0.000 - 1.000 Volt  
B1-S2 OK  
Note  
  
  
  
If specified value is not reached. Check 
oxygen sensor heater   Page 24
-114
   
      If the specified value of "B1-S2 OK" is reached:  
     
- Press -C- button.
     
Test requirements  
     
Engine runs at 1900 - 2200 RPM 
Pa
ge 31 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
Page 32 of 61
     
-  Press buttons -0-, -4- and -4- to select "display 
group number 044" and press -Q- button to 
confirm input. 
Pa
ge 32 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
Page 33 of 61
24-107
 
  
Display fields  
  
1   2   3  
4  
Display group 044: Oxygen sensor aging oxygen sensor behind catalytic converter (Bank 2)  
Display  xxxx/RPM  
xxx C  
x.xxx V  
Test ON  
Indicated  Engine speed 
(RPM)  Exhaust 
temperature  Voltage of oxygen sensor 
behind CAT, Bank 1  Diagnostic condition  
Work range   0 - 6800/RPM  
70 - 850  C  
0.000 - 1.000 Volt  
Test OFF  
Test ON  
B2-S2 OK  
B2-S2 not OK  
Specified 
value  1900 - 
2200/RPM  greater than 320 
C  0.000 - 1.000 Volt  
B1-S2 OK  
Note  
  
  
  
If specified value is not reached. Check 
oxygen sensor heater   Page 24
-114
   
      If the specified value of "B2-S2 OK" is reached:  
     
- Press -C- button.
Pa
ge 33 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
Page 34 of 61
24-108
      
Checking oxygen sensor control behind 
catalytic converter  
     
-  Carry out road test for approx.: 10 minutes.Basic Setting 
Q
Input displa
y group number XXX
    
Indicated on display  
-  Press buttons -0-, -3- and -7- to select "display group number 037" and 
press -Q- button to confirm input. 
System in Basic Setting 37  
1 
2 
3 
4
    
Indicated on display  
-  Check oxygen sensor voltage in display field 2.
-  Check dwell time (hold up) between oxygen sensor 1 before catalytic 
converter and oxygen sensor 2 behind catalytic converter in display 
field 3 and diagnostic result in display field 4. 
Pa
ge 34 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
Page 35 of 61
24-109
 
  
Display fields  
  
1   2   3   4  
Display group 037: Diagnostic oxygen sensor control (Bank 1)  
Display   xxx %   x.xxx Volt   xxx ms  
Test ON  
Indicated  Engine 
load  Oxygen sensor voltage behind 
catalytic converter, Bank 1  Correction value between 
oxygen sensor 1 and sensor 
2, bank 1  Diagnostic condition  
Work 
range  15.0 - 
175.0 %  0.000 - 1.000 V   -1200 - 1200 ms  
Test OFF  
Test ON  
SYST. OK  
SYST. not OK  
Specified 
value  15.0 - 
25.0 %  0.000 - 1.000 V   -500 - 500 ms  
SYST. OK  
Note  
  
If specified value is not 
obtained: Evaluation display 
field 2   Page 24
-112
   
If specified value is 
obtained: Continuation   
Page 24
-113
   
If "SYST. not OK" is 
displayed: Check DTC 
memory  Page 01
-15
   
or Continue   Page 24-113
   
Note for display field 3:  
Oxygen sensor control behind catalytic converter is superior to oxygen sensor control before catalytic converter and is the 
primary control. It corrects slight changes in the mixture (i.e. enrichment or thinning) by holding the oxygen sensor control 
before catalytic converter at its higher or lower point for a specific time (duration). If this time is in the positive range (i.e. 50 
ms), mixture is shifted in the -enrich- direction. If this time is in the negative range (i.e. 50 ms), mixture is shifted in the -lean- 
Pa
ge 35 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
Page 36 of 61
direction. 
Pa
ge 36 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
Page 37 of 61
24-110
      
- Press -C- button.
     
-  Press buttons -0-, -3- and -8- to select "display 
group number 038" and press -Q- button to 
confirm input. System in Basic Setting 38  
1 
2 
3 
4
    
Indicated on display: (1 - 4   display fields)  
Pa
ge 37 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
Page 38 of 61
24-111
 
  
Display fields  
  
1   2   3   4  
Display group 038: Diagnostic oxygen sensor control (Bank 2)  
Display   xxx %   x.xxx Volt   xxx ms  
Test ON  
Indicated  Engine 
load  Oxygen sensor voltage behind 
catalytic converter, Bank 2  Correction value between 
oxygen sensor 1 and sensor 
2, bank 2  Diagnostic condition  
Work 
range  15.0 - 
175.0 %  0.000 - 1.000 V   -1200 - 1200 ms  
Test OFF  
Test ON  
SYST. OK  
SYST. not OK  
Specified 
value  15.0 - 
25.0 %  0.000 - 1.000 V   -500 - 500 ms  
SYST. OK  
Note  
   If specified value is not obtained: 
Evaluation display field 2   
Page 24
-112
   
If specified value is obtained: 
Continuation  Page 24
-113
   
If "SYST. not OK" is 
displayed: Check DTC 
memory  Page 01
-15
   
or Continue   Page 24-113
   
Note for display field 3:  
Oxygen sensor control behind catalytic converter is superior to oxygen sensor control before catalytic converter and is the 
primary control. It corrects slight changes in the mixture (i.e. enrichment or thinning) by holding the oxygen sensor control 
before catalytic converter at its higher or lower point for a specific time (duration). If this time is in the positive range (i.e. 50 
ms), mixture is shifted in the -enrich- direction. If this time is in the negative range (i.e. 50 ms), mixture is shifted in the -lean- 
Pa
ge 38 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
Page 39 of 61
direction. 
Pa
ge 39 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
Page 40 of 61
24-112
 Evaluation display group 037 and 038  Display Group: 
037/038  
  
  
Display field: 2  
Possible cause  
Corrective action  
approx.: 0.450 V  
 
Open circuit in wire 4 between oxygen sensor 
and control module - Check signal wire and activation   Page 24
-
122
 
  
 
Open circuit in wire 3 between oxygen sensor 
and control module   
  
    Oxygen sensor heater faulty
 Oxygen sensor faulty- Check oxygen sensor heater   Page 24
-114
- Replace oxygen sensor
greater than 
1.100 V   
Short circuit to B+ in wire 4 between oxygen 
sensor and control module - Check oxygen sensor wiring bank 1 sensor 2 
(behind converter)   Page 24
-125
 
smaller than 
0.100 V   
Short circuit to Ground (GND) in wire 4 between 
oxygen sensor and control module 
 Short circuit between wire 3 and 4- Check oxygen sensor wiring bank 2 sensor 2 
(behind converter)   Page 24