fuel AUDI A4 1998 B5 / 1.G Instrument Cluster OBD From Model Year 2000 User Guide

Page 79 of 99

01-142

Rapid data transfer
HELP
Select function XX

Indicated on display
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
10 - Adaptation

Indicated on display
Note:
If input is incorrect, tester switches to function mode. - Press -Q- button to confirm input.
Function is unknown or
cannot
be carried out at the moment

Indicated on display:
-
Press button.- Select "Adaptation" function 10 again and select adaptation channel
03.
- Perform correction of fuel gauge again.
Pa
ge 79 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 92 of 99

01-155

Adaptation of fuel gauge sender resistance
range
This function is used to adjust the fuel gauge
sender resistance range if the fuel gauge display
in the instrument cluster does not match the
actual amount of fuel in the tank. Rapid data transfer
HELP
Select function XX

Indicated on display
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
10 - Adaptation

Indicated on display
- Press -Q- button to confirm input.
Adaptation Input channel number XX

Indicated on display:
- Press buttons -3- and -0-.
- Press -Q- button to confirm input.
Pa
ge 92 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 93 of 99

01-156

Channel 30 Adaptation 128 Tank sender - 1 3-

Indicated on display: Adaptation value is displayed, for example 128.
Notes:
"128" is the adaptation value for the standard resistance range for the
fuel gauge sender as set by the factory. The resistance value for the fuel gauge sender resistance range can
be adjusted by 8 Ohm to give an adaptation value between 120 and
136. If the value "128" was changed due to a customer complaint, the
changed value must be transferred when replacing instrument cluster.
-
Press button.
Channel 30 Adaptation 128 Input adaptation value XXXXX

Indicated on display:
Example:
Desired input value: 132
Keypad input: 00132 - Input desired correction value using scan tool keypad, filling initial
positions with "0" and watch how the display responds.
Channel 30 Adaptation 128
Q
Input adaptation value 00132

Indicated on display:
- Press -Q- button to confirm input.
Pa
ge 93 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 94 of 99

01-157

Channel 30 Adaptation 132
Q
Tank sender - 1 3-

Indicated on display:
- Press -Q- button to confirm input.
Channel 30 Adaptation 132
Q
Store changed value?

Indicated on display:
- Press -Q- button to confirm input.
Channel 30 Adaptation 132 Changed value is stored

Indicated on display:
- End adaptation of the fuel gauge sender resistance range by pressing
the button.
Pa
ge 94 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page:   < prev 1-10 11-20