lock AUDI A4 1999 B5 / 1.G AEB Engine Readiness Codes
Page 2 of 22
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block"
function 08, and press -Q- button to confirm input.
Pa
ge 2 of 22 Readiness code
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.01.2
Page 3 of 22
01-60
Read Measurin
g Value Block
HELP
Input display group number XXX
Indicated on display
- Press buttons -0-, -8- and -6- to input display group number 86, and
press -Q- button to confirm input.
Read Measurin
g Value Block 86
1
2
3
4
Indicated on display (1-4 display fields)
Note:
The readiness code is generated as soon as only zeros ("0") are shown in
display field 1. - Check readiness code values in display field 1.
Specified value: 00000000
-
Press button to advance program sequence.
Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -6- to select "End Output" function 06, and press
-Q- button to confirm input.
Pa
ge 3 of 22 Readiness code
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.01.2
Page 8 of 22
01-65
Step 3: Adaptation of throttle valve control
module to ECM Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -8- to select "Read Measuring Value Block"
function 08, and press -Q- button to confirm input.
Read Measuring Value Block
HELP
Input displa
y group number XXX
Indicated on display
- Press buttons -0-, -6- and -0- to input display group number 60, and
press -Q- button to confirm input.
Read Measuring Value Block 60
1
2
3
4
Indicated on display (1-4 display fields) - Press -4- button to select "Basic Setting" function 04 (adaptation of
throttle valve control module to ECM)
System in Basic Setting 60
1
2
3
4
Indicated on display (1-4 display fields) - Check specified values in display fields 3 and 4:
Pa
ge 8 of 22 Readiness code
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.01.2
Page 11 of 22
01-68
Step 5: Oxygen Sensor (O2S) control
operating condition Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -8- to select "Read Measuring Value Block"
function 08, and press -Q- button to confirm input.
Read Measuring Value Block
HELP
Input displa
y group number XXX
Indicated on display
- Press buttons -0-, -3- and -0- to input display group number 30, and
press -Q- button to confirm input.
Read Measuring Value Block 30
1
2
3
4
Indicated on display (1-4 display fields) - Increase engine speed to 1800-2200 RPM.
- Hold at 1800-2200 RPM until:
Specified value of "111" is reached in display field 1
Specified value of "110" is reached in display field 2
Pa
ge 11 of 22 Readiness code11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.01.2