lock AUDI A4 1999 B5 / 1.G ATQ Engine Ignition System Checking User Guide

Page 57 of 65

- Press buttons -0-, -9- and -3- to select "display group number 093" and
press -Q- button to confirm input.
Read Measuring Value Block 93
1
2
3
4

When indicated on display:
- Check specified values of Camshaft Position (CMP) sensor
Pa
ge 57 of 65 I
gnition s
ystem, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.28.1

Page 58 of 65

28-51


Display fields

1 2 3 4
Display group 093: Phase position of Camshaft Position (CMP) sensor bank 1 and bank 2 with engine at idle.
Display xxx /min xx %
KW
KW
Indicated Engine
speed Engine
load Phase position
Bank 1 Phase position
Bank 2
Functional
range 630 to 6800
RPM 12 to 100
% -20 to 15 KW
-20 to 15 KW
Specified
value 720 to 820
RPM
1)
630 to 730
RPM 2) 12 to 26
% -20 to 15 KW
-20 to 15 KW
Notes

If specified values are not reached, unscrew Camshaft Position (CMP)
sensor and check whether shutter wheel is mounted properly at camshaft
(if mounted improperly, locking lug will get squished when mounting bolt is
tightened).
Repair Manual, Engine, Mechanical, Repair Group 13, removing and installing
toothed belt - Also check engine timing
1) Front Wheel Drive Vehicles 2) All-Wheel Drive Vehicles
Pa
ge 58 of 65 I
gnition s
ystem, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.28.1

Page 60 of 65

28-52

Misfire recognition, checking


Test sequence

- Connect VAS5051 tester or VAG1551 scan tool
and select the control module for engine
electronics using "address word" 01 Page 01
-
9 .

Engine must run at idle for this.Rapid data transfer
HELP
Select function XX

When indicated on display:
- Press buttons -0- and -8- to select "Read measuring value block"
function 08. Press -Q- button to confirm input.
Read Measuring Value Block
Q
Input displa
y group number XXX

When indicated on display:
- Press buttons -0-, -1- and -4- to select "display group number 014" and
press -Q- button to confirm input.
Read Measuring Value Block 14
1
2
3
4

When indicated on display:
- Check misfire recognition in display fields 3 and 4.
Pa
ge 60 of 65 I
gnition s
ystem, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.28.1

Page 61 of 65

28-53


Display fields

1 2 3 4
Display group 014: Misfire recognition
Display xxxx/min xxx %
xxx
---
Indicated Engine speed
(RPM) Load
Number of combustion misfires
Misfire
recognition
Functional
range 670 to 6800
RPM 12 to
100 %
activated
locked
Specified
value 720 to 820
RPM
1)
630 to 730
RPM 2) 12 to 26
% 0 to 12
activated
Notes
If the specified value is exceeded: Check combustion
misfires of the individual cylinders Page 28
-54


1) Front Wheel Drive Vehicles 2) All-Wheel Drive Vehicles
If specified value is obtained:

-
Press button.Rapid data transfer
HELP

Indicated on display (function selection):
Pa
ge 61 of 65 I
gnition s
ystem, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.28.1

Page 63 of 65

28-54

Check misfire recognition of the individual
cylinders.

- Press -C- button.Read Measuring Value Block
Q
Input displa
y group number XXX

When indicated on display:
- Press buttons -0-, -1- and -5- to select "display group number 015"
and press -Q- button to confirm input.
Read Measuring Value Block 15
1
2
3
4

When indicated on display:
- Check misfire recognition in display fields 1 to 4.

Display fields

1 2 3 4
Display group 015: Misfire recognition of cylinders 1, 2 and 3
Display
xxx
xxx
xxx
---
Indicated
Number of combustion
misfires, cylinder 1 Number of combustion
misfires, cylinder 2 Number of combustion
misfires, cylinder 3 Misfire
recognition
Functional
range


activated
locked
Specified
value 0 to 15
0 to 15
0 to 15
activated
Notes
If the specified value is exceeded: Evaluation Page 28
-56

--- Pa
ge 63 of 65 I
gnition s
ystem, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.28.1

Page 64 of 65

28-55

- Press -C- button.Read Measuring Value Block
Q
Input display group number XXX

When indicated on display:
- Press buttons -0-, -1- and -4- to select "display group number 014"
and press -Q- button to confirm input.
Read Measuring Value Block 16
1
2
3
4

When indicated on display:
- Check misfire recognition in display fields 1 to 4.

Display fields

1 2 3 4
Display group 016: Misfire recognition of cylinders 4, 5 and 6
Display
xxx
xxx
xxx
---
Indicated
Number of combustion
misfires, cylinder 4 Number of combustion
misfires, cylinder 5 Number of combustion
misfires, cylinder 6 Misfire
recognition
Functional
range


activated
locked
Specified
value 0 to 15
0 to 15
0 to 15
activated
Notes
If the specified value is exceeded: Evaluation Page 28
-56

--- Pa
ge 64 of 65 I
gnition s
ystem, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.28.1

Page:   < prev 1-10 11-20