24-119
 
Read Measuring Value Block 42  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified values in display fields 1 and 3.
  
Display fields  
  
1   2   3   4  
Display group 042: Oxygen sensor heating (bank 2) at idle  
Display  
xxx kOhm  ---  
xxx kOhm  ---  
Indicated  
Bank 2, sensor 1   Condition of heating  
Bank 2, sensor 2   Condition of heating  
Functional range      Htng. bef. cat. ON  
Htng. bef. cat. OFF     Htng. beh. cat. ON  
Htng. beh. cat. OFF  
Specified value  
0 to 0.9 kOhm   Htng. bef. cat. ON/OFF  
0 to 0.9 kOhm   Htng. beh. cat. ON/OFF  Important notes to display fields 1, 2, 3 and 4:  
 
If oxygen sensors have not yet reached their operating temperature, there will be no indication in display fields 1 and 3, 
i.e. they will both be empty. (increase engine speed to obtain specified values). 
 After reaching operating temperature of the two oxygen sensors, a resistance of less than 0.9 kOhm must be indicated in 
display fields 1 and 3. 
 Do not continue test until a resistance of less than 0.9 kOhm is indicated in display fields 1 and 3.
 At certain points of operation, the ECM "pulses" oxygen sensor heating. This means that oxygen sensor heating is 
switched on and off at these points. It is entirely possible that the specified value "Htng. bef. Cat. OFF" or "Htng. beh. Cat. 