display AUDI A4 1999 B5 / 1.G ATQ Engine Oxygen Sensor Control Checking
Page 51 of 63
24-118
 
  
Display fields  
  
1   2   3   4  
Display group 041: Oxygen sensor heating (bank 1) at idle  
Display  
xxx kOhm  ---  
xxx kOhm  ---  
Indicated  
Bank 1, sensor 1   Condition of heating  
Bank 2, sensor 1   Condition of heating  
Functional range      Htng. bef. cat. ON  
Htng. bef. cat. OFF     Htng. beh. cat. ON  
Htng. beh. cat. OFF  
Specified value  
0 to 0.9 kOhm   Htng. bef. cat. ON/OFF  
0 to 0.9 kOhm   Htng. beh. cat. ON/OFF  Important notes to display fields 1, 2, 3 and 4:  
 
If oxygen sensors have not yet reached their operating temperature, there will be no indication in display fields 1 and 3, 
i.e. they will both be empty. (increase engine speed to obtain specified values). 
 After reaching operating temperature of the two oxygen sensors, a resistance of less than 0.9 kOhm must be indicated in 
display fields 1 and 3. 
 Do not continue test until a resistance of less than 0.9 kOhm is indicated in display fields 1 and 3.
 At certain points of operation, the ECM "pulses" oxygen sensor heating. This means that oxygen sensor heating is 
switched on and off at these points. It is entirely possible that the specified value "Htng. bef. Cat. OFF" or "Htng. beh. Cat. 
OFF" will appear in display fields 2 and 4 
     
- Press -C- button.
Pa
ge 51 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
Page 52 of 63
Read Measurin
g Value Block 
Q
Input display group number XXX
    
When indicated on display:  
-  Press buttons -0-, -4- and -2- to select "display group number 042" and press -Q-
button to confirm input. 
Pa
ge 52 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
Page 53 of 63
24-119
 
Read Measuring Value Block 42  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified values in display fields 1 and 3.
  
Display fields  
  
1   2   3   4  
Display group 042: Oxygen sensor heating (bank 2) at idle  
Display  
xxx kOhm  ---  
xxx kOhm  ---  
Indicated  
Bank 2, sensor 1   Condition of heating  
Bank 2, sensor 2   Condition of heating  
Functional range      Htng. bef. cat. ON  
Htng. bef. cat. OFF     Htng. beh. cat. ON  
Htng. beh. cat. OFF  
Specified value  
0 to 0.9 kOhm   Htng. bef. cat. ON/OFF  
0 to 0.9 kOhm   Htng. beh. cat. ON/OFF  Important notes to display fields 1, 2, 3 and 4:  
 
If oxygen sensors have not yet reached their operating temperature, there will be no indication in display fields 1 and 3, 
i.e. they will both be empty. (increase engine speed to obtain specified values). 
 After reaching operating temperature of the two oxygen sensors, a resistance of less than 0.9 kOhm must be indicated in 
display fields 1 and 3. 
 Do not continue test until a resistance of less than 0.9 kOhm is indicated in display fields 1 and 3.
 At certain points of operation, the ECM "pulses" oxygen sensor heating. This means that oxygen sensor heating is 
switched on and off at these points. It is entirely possible that the specified value "Htng. bef. Cat. OFF" or "Htng. beh. Cat. 
Pa
ge 53 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
Page 54 of 63
OFF" will appear in display fields 2 and 4 
Pa
ge 54 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
Page 57 of 63
24-122
      
- Start engine.
     
 
Specification: approx. battery voltage, 
possibly fluctuating 
     
Notes:  
     
At certain operating points, the ECM "pulses" 
the Ground (GND) for oxygen sensor heating. 
This means that the Ground (GND) is 
constantly switched on and off at these points. 
It is therefore possible that the voltage 
displayed on the tester will fluctuate. 
     It is possible to observe the ECM switching 
oxygen sensor heating on and off within the 
function "read measuring value block", display 
group numbers 041 and 042. 
      If there is no voltage:  
    
-  Connect multimeter for voltage measurement as follows:Harness connector  
Terminal  
Measure to  
1 (B+)   Vehicle Ground (GND)  
-  Operate starter briefly. 