relay AUDI A4 2000 B5 / 1.G AFC Engine Fuel Injector Leak Testing And Delivery Quantity Checking Workshop Manual

Page 2 of 5

24-34

Checking fuel injector leakage

CAUTION!

Fire hazard! Do not smoke, work near heaters
or open flame, or have anything in the area
that could ignite fuel.

- Use scan tool "Output Diagnostic Test Mode"
function 03 to trigger fuel pump relay -J17-
Repair Group 01.
- Visually inspect fuel injector for leaks (with fuel
pump running).

Maximum: Two drops per minute per fuel
injector
If fuel loss exceeds 2 drops per minute:

- Switch ignition OFF and replace leaking fuel
injector.

Note:
Always replace O-rings!
Pa
ge 2 of 5 Fuel in
jector leak testin
g and deliver
y quantit
y, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.24.7

Page 3 of 5

24-35

Checking fuel injector delivery quantity

CAUTION!

Fire hazard! Do not smoke, work near heaters
or open flame, or have anything in the area
that could ignite fuel.

- Insert fuel injector to be tested into calibrated measuring container from
1602 fuel analyzer kit.

- Connect one terminal of each fuel injector being tested to engine
Ground (GND) using jumper wire from connector test kit VW 1594.
- Connect remaining fuel injector terminal to B+ using remote control
VAG 1348/3A, adapter wire VAG 1248/3-2 and jumper wire from
connector test kit VW 1594.
- Use scan tool "Output Diagnostic Test Mode" function 03 to trigger fuel
pump relay -J17- Repair Group 01. - Operate remote control VAG 1348/3A for 30 seconds.
Pa
ge 3 of 5 Fuel in
jector leak testin
g and deliver
y quantit
y, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.24.7