air condition AUDI A6 1995 C5 / 2.G ATQ Engine Motronic Injection System Servicing Workshop Manual
Page 29 of 78
24-27
 
Basic Settin
g 
Q
Input display group number XXX
    
When indicated on display:  
-  Press buttons -0-, -5- and -6- to select "display group number 056" and press -Q-
button to confirm input. 
System in Basic Setting 56  
1 
2 
3 
4 
    
When indicated on display:  
-  Check whether the engine speed in display field 1 (actual engine speed) is within 
tolerated range. 
  
Display fields  
  
1   2   3   4  
Display group 056: Idle stabilization with engine at idle and operating temperature  
Display  
xxx /min  
xxx /min   x.x %   X X X X X  
Indicated  
Engine speed (actual)  
Engine speed 
(specified)  Idle control  
Torque 
change  Operating conditions  
Specified 
value  720 to 820 RPM 
1)  
630 to 730 RPM 2)  770 RPM 
1)  
680 RPM 2)  -5 to 5 %   0 0 0 0 0  
Notes  
If specified value is not obtained   
Page 24
-29
   
    Significance of 
numbers 
 Page 24
-29
   
1) Front Wheel Drive Vehicles  
Pa
ge 29 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1