diagram AUDI A6 1996 C5 / 2.G ATQ Engine Tank Ventilation Checking Workshop Manual
Page 5 of 7
24-131
      
Checking voltage supply  
     
Test requirements:  
     
Fuse for the EVAP valve OK. 
     
       Electrical Wiring Diagrams, Troubleshooting & 
Component Locations binder   
     
Fuel Pump (FP) OK, checking   Page 24
-
49
 . 
     
Note:  
     Voltage is supplied to the EVAP valve via the 
Fuel Pump (FP) relay. 
     
-  Disconnect connector at EVAP valve.
    
-  Connect VAG1527B voltage tester as follows:Harness connector  
Terminal  
Measure to  
1   Engine Ground (GND)  
-  Operate starter briefly (engine can also start).
 
LED must light up.
Pa
ge 5 of 7 Tank ventilation, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.4 
Page 6 of 7
24-132
       If LED does not light up:  
     
-  Check wire connection from terminal 1 to Fuel 
Pump (FP) relay via fuse for open circuit. 
     
       Electrical Wiring Diagrams, Troubleshooting & 
Component Locations binder        
-  Repair open circuit if necessary.
      If LED lights up:  
     
- Checking activation.
     
Checking activation  
    
-  Connect VAG1527B voltage tester to connector terminals 1 (B+) and 2.
-  Initiate output DTM and activate Evaporative Emission (EVAP) canister 
purge regulator valve -N80-   Page 01
-56
 . 
 
LED must blink.
Pa
ge 6 of 7 Tank ventilation, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.4