relay AUDI A6 1998 C5 / 2.G ATQ Engine Motronic Injection System Servicing Workshop Manual
Page 10 of 78
24-8
 
  
10 - 
E-box in plenum chamber 
Motronic Engine Control Module (ECM) -
J220- Secondary Air Injection (AIR) Pump Relay -
J299-  Fig.  10
 , page   Page 24
-12
 
11 - 
Valve -2- for camshaft adjustment -N208- 
12 - 
Camshaft Position (CMP) sensor 2 -G163- 
Bank 1
13 - 
Heated Oxygen Sensor (HO2S) -G39- 
before catalytic converter with Oxygen 
Sensor (O2S) Heater -Z19- Bank 1, sensor 1
14 - 
Ground connection on the engine bracket, right side
15 - 
Mass Air Flow (MAF) sensor -G70- Checking  Page 24
-56
16 - 
Evaporative Emission (EVAP) canister 
purge regulator valve -N80- 
Pa
ge 10 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 14 of 78
24-12
 
    
Note:  
In order to assure sufficiently secure fitting, switches must not be installed 
more than once. 
Adjusting switch: 
 Repair Manual, Brake System, ABS, ABS/EDL, Repair Group 46
    Fig. 9  Component location Brake Light Switch -F- and Brake 
Vacuum Vent Valve Switch For Cruise Control/Diesel Fuel 
Injection, Clutch Vacuum Vent Valve Switch -F36- 
1 - Clip
2 - Brake Light Switch -F-, Brake Vacuum Vent Valve Switch For Cruise 
Control/Diesel Fuel Injection -F47- 
3 - Clutch vacuum vent valve switch -F36-
    
Secondary Air Injection (AIR) Pump Relay -J299- (arrow) in 3-pin relay 
carrier in E-box, plenum chamber.  Fig. 10  Component location for Secondary Air Injection (AIR) 
Pump Relay -J299- 
Pa
ge 14 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 15 of 78
24-13
 
    
Fuel Pump (FP) Relay -J17- is located at position 4 of central electrics in 
driver's footwell, left.  Fig. 11  Component locations Fuel Pump (FP) Relay -J17-
    
Data Link Connector (DLC) in knee bolster on driver's side.  Fig. 12  Component location of Data Link Connector (DLC)
Pa
ge 15 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 55 of 78
24-46
      
Test requirement:  
     
Fuel pressure OK, checking   Page 24
-30
 . 
     
Test sequence  
     
-  Remove fuel distributor including fuel injectors 
from intake manifold   Page 24
-43
 . Fuel lines 
remain connected. 
     
-  Connect VAG1598/31 test box at wiring harness 
to ECM, do not connect ECM   Page 24
-17
 . 
     
-  Bridge terminals 1 and 65 at test box using 
adapter cables from VAG1594A connector test 
kit (this step supplies Ground -GND- to one side 
of relay coil for Fuel Pump -FP- relay). 
     
Note:  
     Fuel Pump (FP) relay is supplied with B+ via the 
central electric (terminal 30). Fuel Pump (FP) 
relay receives minus via the cable bridge in test 
box. The Fuel Pump (FP) is now running 
constantly. 
Pa
ge 55 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 59 of 78
24-49
 
  
Fuel Pump (FP) relay -J17- and activation, 
checking
 
Special Tools and Equipment  
 
VAG1526A
 VAG1594A
 VAG1598/31
 VAS5051 with VAG5051/1
- or 
 VAG1551 with VAG1551/3B
Pa
ge 59 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 60 of 78
24-50
       Voltage is supplied to the Fuel Pump (FP) and 
several components of the injection system via 
the Fuel Pump (FP) relay -J17-.  
      Engine must be turning for Fuel Pump (FP) relay 
-J17- to close. This means that the relay does 
not receive Ground (GND) (via ECM) until the 
ECM recognizes RPM signals.  
     
Note:  
    
Fuel Pump (FP) relay is located at position 4 of central electrics in driver's 
footwell, left. 
Test requirement: 
Battery voltage at least 12.7 V 
Pa
ge 60 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 61 of 78
24-51
      
Function test of Fuel Pump (FP) relay  
     
-  Remove driver-side storage compartment.
     
       Repair Manual, Body
-Interior, Repair Group 
68; Instrument Panel; Removing Driver
-Side 
Storage Compartment
   
     
-  Connect VAS5051 tester or VAG1551 scan tool 
and select the control module for engine 
electronics using "address word" 01   Page 01
-
9 . 
     
   Ignition must remain switched on for this.
     
-  Initiate output Diagnostic Test Mode   Page 01
-
56
 and activate Evaporative Emission (EVAP) 
canister purge regulator valve -N80-. 
    
A - If relay does not trigger:   
Fuel Pump (FP) relay (at position 4 of central electrics in driver's 
footwell, left) must trigger and Fuel Pump (FP) must run. 
-  Check voltage supply of Fuel Pump (FP) relay   Page 24
-52
 .
-  Checking activation of Fuel Pump (FP) relay   Page 24
-52
 .Pa
ge 61 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 62 of 78
24-52
       B - If relay triggers, but Fuel Pump (FP) does not 
run:  
     
-  Check voltage supply for Fuel Pump (FP) and 
components (via Fuel Pump -FP- relay)   Page 
24
-54
 . 
     
Check voltage supply of Fuel Pump (FP) 
relay  
     
-  Remove Fuel Pump (FP) relay.
    
If specified value is not obtained:  
Checking activation of Fuel Pump (FP) relay   -  Connect multimeter to terminal 17 of relay socket and Ground (GND) 
for voltage measurement. 
 
Specification: approx. battery voltage
-  Replace central electrics. 
-  Switch ignition off.
-  Connect VAG1598/31 test box at wiring harness to ECM, do not 
connect ECM   Page 24
-17
 . 
-  Bridge terminals 1 and 65 at test box using wires from VAG1594A 
adapter test kit. 
Pa
ge 62 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 63 of 78
24-53
 
    
If relay triggers now, but didn't during output DTM:  
If relay does not trigger:   
Fuel Pump (FP) relay (at position 4 of central electrics in driver's 
footwell, left) must trigger. 
-  Replace Engine Control Module (ECM)   Page 24
-21
 .
-  Remove cable bridge. 
-  Remove Fuel Pump (FP) relay.
    
If specified value is not obtained:  
 Electrical Wiring Diagrams, Troubleshooting & Component Locations 
binder    -  Connect multimeter to terminal 19 of relay socket and Ground (GND) 
for voltage measurement. 
 
Specification: approx. battery voltage
-  Check wire connections. 
Pa
ge 63 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 64 of 78
24-54
       If specified value is obtained:  
    
If no malfunctions are detected:  
Check voltage supply for Fuel Pump (FP) and components   -  Check the following wire connection for open circuit and short circuit to 
Ground (GND) and B+: 
Central electric 
in driver-side footwell, left, position 4  
Terminal  
VAG1598/31 test box  
  
  
Socket  
16   65  
-  Repair open circuit or short circuit if necessary.
-  Replace Fuel Pump (FP) relay -J17-.
-  Re-connect Engine Control Module (ECM).
    
-  Remove fuses S228, S229, and S234 (positions 28, 29, and S234) 
from fuse holder. 
-  Initiate output Diagnostic Test Mode   Page 01
-56
 and activate 
Evaporative Emission (EVAP) canister purge regulator valve -N80-. 
Pa
ge 64 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1