remote control AUDI A6 1998 C5 / 2.G ATQ Engine Motronic Injection System Servicing Workshop Manual
Page 56 of 78
24-47
      
Checking Proper Seal  
     
-  Check proper seal of fuel injectors (visual 
inspection). With Fuel Pump (FP) running, only 1 
to 2 drops per minute may drip out per injector. 
     
-  If fuel loss is greater, stop Fuel Pump (FP) from 
running (disconnect cable bridge) and replace 
faulty fuel injector   Page 24
-43
 . 
     
Checking Injection Quantity  
    
-  Insert fuel injector to be tested in a measuring glass from VAG1602 
injection quantity test device. 
    
-  Connect one terminal of fuel injector to engine Ground (GND) using an 
adapter cable and an alligator clip from VAG1594A connector test kit. 
-  Connect the second terminal of fuel injector to B+ using VAG1348/3A 
remote control, VAG1348/3-2 adapter cable and assisting cable. 
Pa
ge 56 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 57 of 78
24-48
      
-  Bridge terminals 1 and 65 at test box using wires 
from VAG1594A adapter test kit. 
     
 
Fuel Pump (FP) must run.
     
-  Operate VAG1348/3A remote control for 30 
seconds. 
     
-  After all three fuel injectors of one cylinder row 
have been activated, place measuring glasses 
on an even surface. 
     
 Specified value for each fuel injector: 90 to 
125 ml. 
     
-  If measured value of one or more fuel injectors 
is outside of specified range, switch Fuel Pump 
(FP) off (disconnect cable bridge) and replace 
faulty fuel injector   Page 24
-43
 . 
     
-  Repeat test at fuel injectors of second cylinder 
row. 
     
-  If the measured values of all fuel injectors are 
outside the specified range, check fuel pressure 
 Page 24
-30
 . 
     
Note:  
Pa
ge 57 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1