AUDI A6 1998 C5 / 2.G ATW Engine Read Measuring Value Block Workshop Manual
Page 1 of 2
01-65
 
     
Read Measuring Value Block 
(function 08) 
     
Test requirements:  
     
Coolant Temperature at least 80 C. 
     
Electrical consumers switched off (radiator 
fan must NOT run during test). 
     A/C switched off. 
     
Test sequence  
     
-  Connect VAS5051 tester or VAG1551 scan tool 
and select control module for engine electronics 
using "address word" 01   Page 01
-10
 . Engine 
must run at idle. 
Rapid data transfer 
HELP
Select function XX
    
When indicated on display  
-  Press buttons -0- and -8- to select "Read Measuring Value Block" and 
press -Q- button to confirm input. 
Read measurin
g value block 
Q
Enter displa
y group number XXX
    
When indicated on display  
-  Enter desired three digit display group number and confirm by pressing 
-Q- button. 
Pa
ge 1 of 2 Read Measurin
g Value Block 
(function 08
)
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.01.7 
Page 2 of 2
01-66
      
Note:  
     Which display group should be chosen depends 
on current function and component tests. Read Measuring Value Block 0 1 
2 
3 
4 
5 
6 
7 
8 
9 
10
    
Indicated on display for display group 000  
Read Measuring Value Block 1 1 
2 
3 
4
    
Indicated on display (example) for display group 001  
Note: 
Display can be printed out on the paper roll when printer is switched 
on. To switch to a different display group, proceed as follows:
Display group  
VAG1551 Scan Tool  
VAS5051 tester  
Higher   Press button -3-  
Press  button.  
Lower   Press button -1-  
Press  button.  
Pa
ge 2 of 2 Read Measurin
g Value Block 
(function 08
)
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.01.7