clutch AUDI A6 1999 C5 / 2.G ATW Engine Readiness Code Workshop Manual
Page 17 of 35
01-80
      
Work step 5: Check operating condition of 
oxygen sensor control 
     
-  Start engine (for a vehicle with manual 
transmission: engage clutch). 
     
Note:  
     After starting engine, it may be necessary to 
select the Engine Control Module (ECM) again 
using "address word" 01 and the function "Initiate 
basic setting" using "04". 
     
-  Install VAG1788/10 RPM adjuster on accelerator 
pedal and raise engine speed to 2000 RPM. 
     
Test requirement:  
     
Engine running at 2000 RPM. 
Basic Setting 
Q
Enter display group number XXX
    
When indicated on display  
-  Press buttons -0-, -3- and -0- to select "display group number 030" and 
press -Q- button to confirm input. 
System in basic setting 30  
1 
2 
3 
4
    
When indicated on display  
Note:   -  Check oxygen sensor status in display fields 1 and 2.
Pa
ge 17 of 35 Readiness code11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.01.8