fuse box AUDI A6 2000 C5 / 2.G ATQ Engine Motronic Injection System Servicing Workshop Manual

Page 64 of 78

24-54
If specified value is obtained:

If no malfunctions are detected:
Check voltage supply for Fuel Pump (FP) and components - Check the following wire connection for open circuit and short circuit to
Ground (GND) and B+:
Central electric
in driver-side footwell, left, position 4
Terminal
VAG1598/31 test box


Socket
16 65
- Repair open circuit or short circuit if necessary.
- Replace Fuel Pump (FP) relay -J17-.
- Re-connect Engine Control Module (ECM).

- Remove fuses S228, S229, and S234 (positions 28, 29, and S234)
from fuse holder.
- Initiate output Diagnostic Test Mode Page 01
-56
and activate
Evaporative Emission (EVAP) canister purge regulator valve -N80-.
Pa
ge 64 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1