24-95
If residual pressure drops below 2.5 bar (36 psi): - Disconnect vacuum hose (arrow) for fuel pressure regulator.
Fuel pressure must increase to approximately 4.0 bar (58 psi)
- Reconnect vacuum hose.
- Switch ignition off.
- Check for residual fuel pressure by monitoring decrease in pressure on
gauge. Specified value:
After 10 minutes: at least 2.5 bar (36 psi)
- Start engine and let run at idle.
- After pressure has built up, at the same time:
- Switch ignition off.
- Close valve on pressure tester VAG 1318-lever in OFF position
(arrow).
- Monitor decrease in pressure on gauge.