catalytic converter AUDI A8 1995 D2 / 1.G ATQ Engine Readiness Code Workshop Manual
Page 5 of 47
01-80
 
X  
X  
X  
X  
X  
X  
X  
X  
Notes for display group 086, display field 1   
                       
Diagnostic of catalytic converter  
 
Indication 0 = test was performed
 Indication 1 = test was not performed (generate readiness code   Page 01
-82
 )
                    
  
Indication always 0  
                 
     
EVAP system  
 
Indication 0 = test was performed
 Indication 1 = test was not performed (generate readiness code   Page 01
-82
 )
              
        
Secondary Air Injection system  
 
Indication 0 = test was performed
 Indication 1 = test was not performed (generate readiness code   Page 01
-82
 )
           
           
Indication always 0  
        
              
Oxygen sensors  
 
Indication 0 = test was performed
 Indication 1 = test was not performed (generate readiness code   Page 01
-82
 )
     
                 
Oxygen sensor heating  
 
Indication 0 = test was performed
Pa
ge 5 of 47 Readiness code
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 20 of 47
01-91
      
Work step 6: Diagnostic of oxygen sensor 
aging before catalytic converter 
     
Test requirement  
     
Engine continues to run at 2200 RPM. 
Basic Settin
g 
Q
Input display group number XXX
    
When indicated on display:  
-  Press buttons -0-, -3- and -4- to select "display group number 034" and 
press -Q- button to confirm input. 
System in Basic Setting 34  
1 
2 
3 
4
    
When indicated on display:  
Note:  
A few minutes may pass until a diagnostic result is reached.  -  Check specified value in display field 4 after indication "Test ON" 
appears: 
Pa
ge 20 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 21 of 47
01-92
 
  
Display fields  
  
1   2   3   4  
Display group 034: Oxygen sensor aging diagnostic, oxygen sensor before catalytic converter (bank 1)  
Display  xxxx/min  
xxx C  
x.x s  
---  
Indicated  Engine speed 
(RPM)  Exhaust 
temperature  Period duration 
Oxygen sensor 
before  
Catalytic 
converter  Diagnostic condition  
Functional 
range  630 to 6800 
RPM  70 to 850  C  
0 to 3.0 s   Test OFF  
Test ON  
B1-S2 OK  
B1-S2 not OK  
Specified 
value  2200 RPM  
above 380  C  0.1 to 1.8 s   B1-S2 OK  
Notes  
  
  
  
If "B1-S1 not OK" is displayed: Check Diagnostic 
Trouble Code (DTC) memory   Page 01
-15
   
      If specified value "B1-S1 OK" is obtained:  
     
- Press -C- button.Basic Setting 
Q
Input display group number XXX
    
When indicated on display:  
Pa
ge 21 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 23 of 47
01-93
 If specified value "B2-S1 OK" is obtained:  
System in Basic Setting 35  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified value in display field 4.
  
Display fields  
  
1   2   3   4  
Display group 035: Oxygen sensor aging diagnostic, oxygen sensor before catalytic converter (bank 2)  
Display  xxxx/min  
xxx C  
x.x s  
---  
Indicated  Engine speed 
(RPM)  Exhaust 
temperature  Period duration 
Oxygen sensor 
before  
Catalytic 
converter  Diagnostic condition  
Functional 
range  630 to 6800 
RPM  70 to 850  C  
0 to 3.0 s   Test OFF  
Test ON  
B2-S2 OK  
B2-S2 not OK  
Specified 
value  2200 RPM  
above 380  C  0.1 to 1.8 s   B2-S2 OK  
Notes  
  
  
  
If "B2-S1 not OK" is displayed: Check Diagnostic 
Trouble Code (DTC) memory   Page 01
-15
   
- Press -C- button. 
Pa
ge 23 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 24 of 47
01-94
      
Work step 7: Diagnostic of operational 
readiness of oxygen sensors behind catalytic 
converter 
     
Test requirement  
     
Engine continues to run at 2200 RPM. 
Basic Setting 
Q
Input displa
y group number XXX
    
When indicated on display:  
-  Press buttons -0-, -3- and -6- to select "display group number 036" and 
press -Q- button to confirm input. 
System in Basic Setting 36  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified values in display fields 2 and 4.
Pa
ge 24 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 25 of 47
01-95
 
  
Display fields  
  
1   2   3   4  
Display group 036: Operational readiness of the oxygen sensor behind catalytic converter (bank 1 and bank 2)  
Display   x.xxx V  
---   x.xxx V  
---  
Indicated   Voltage of oxygen 
sensors behind 
catalytic converter, 
bank 1  Diagnostic condition   Voltage of oxygen 
sensors behind 
catalytic converter, 
bank 2  Diagnostic condition  
Functional 
range  0.100 to 1.000 V  
Test OFF  
Test ON  
B1-S2 OK  
B1-S2 not OK  0.100 to 1.000 V  
Test OFF  
Test ON  
B2-S2 OK  
B2-S2 not OK  
Specified 
value  smaller than 0.4 V 
or  
larger than 0.5 V  B1-S2 OK   smaller than 0.4 V 
or  
larger than 0.5 V  B2-S2 OK  
Notes  
  
If "B1-S2 not OK" is 
displayed: Check Diagnostic 
Trouble Code (DTC) memory 
 Page 01
-15
   
  
If "B2-S2 not OK" is 
displayed: Check Diagnostic 
Trouble Code (DTC) memory 
 Page 01
-15
   
      If specified value "B1-S1 OK" is obtained:  
     
- Press -C- button. 
Pa
ge 25 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 27 of 47
01-97
 
  
Display fields  
  
1   2   3   4  
Display group 037: Diagnostic of oxygen sensor control system (Bank 1)  
Display   xxx %   x.xxx volts   xxx ms  
---  
Indicated   Load   Voltage of oxygen sensors 
behind catalytic converter, 
bank 1  Oxygen sensor 
correction value  
between sensor 1 
and sensor 2 (bank 
1)  Diagnostic condition  
Functional 
range  12 to 
100 %  0.100 to 1.000 V   -800 to 800 ms  
Test OFF  
Test ON  
System OK  
System not OK  
Specified 
value  12 to 26 
%  0.100 to 1.000 V   -800 to 800 ms   System OK  
Notes  
  
  
  
If "System not OK" is displayed: Check 
Diagnostic Trouble Code (DTC) memory 
 Page 01
-15
   
      If specified value "Syst. OK" is obtained:  
     
- Press -C- button. Basic Settin
g 
Q
    
When indicated on display:  
Pa
ge 27 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 29 of 47
01-98
 If specified value "Syst. OK" is obtained:  
System in Basic Setting 34  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified value in display field 4.
  
Display fields  
  
1   2   3   4  
Display group 038: Diagnostic of oxygen sensor control system (Bank 2)  
Display   xxx %   x.xxx volts   xxx ms  
---  
Indicated   Load   Voltage of oxygen sensors 
behind catalytic converter, 
bank 2  Oxygen sensor 
correction value  
between sensor 2 
and sensor 2 (bank 
1)  Diagnostic condition  
Functional 
range  12 to 
100 %  0.100 to 1.000 V   -800 to 800 ms  
Test OFF  
Test ON  
System OK  
System not OK  
Specified 
value  12 to 26 
%  0.100 to 1.000 V   -800 to 800 ms   System OK  
Notes  
  
  
  
If "System not OK" is displayed: Check 
Diagnostic Trouble Code (DTC) memory 
 Page 01
-15
   
- Press -C- button. 
Pa
ge 29 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 30 of 47
01-99
      
Work step 9: Diagnostic of oxygen sensor 
aging behind catalytic converter 
     
Test requirement  
     
Engine continues to run at 2200 RPM. 
Basic Settin
g 
Q
Input display group number XXX
    
When indicated on display:  
-  Press buttons -0-, -4- and -3- to select "display group number 043" and 
press -Q- button to confirm input. 
System in Basic Setting 43  
1 
2 
3 
4
    
When indicated on display:  
-  Check specified value in display field 4.
Pa
ge 30 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7 
Page 31 of 47
01-100
 
  
Display fields  
  
1   2   3   4  
Display group 043: Oxygen sensor aging diagnostic, oxygen sensor behind catalytic converter (bank 1)  
Display  xxxx/min  
xxx C  
x.x s  
---  
Indicated  Engine speed 
(RPM)  Exhaust 
temperature  Voltage of oxygen sensors 
behind catalytic converter, 
bank 1  Diagnostic condition  
Functional 
range  630 to 6800 
RPM  70 to 850  C  
0.100 to 1.000 V   Test OFF  
Test ON  
B1-S2 OK  
B1-S2 not OK  
Specified 
value  2200 RPM  
above 380  C  0.100 to 1.000 V   B1-S2 OK  
Notes  
  
  
  
If "B1-S2 not OK" is displayed: Check 
Diagnostic Trouble Code (DTC) memory 
 Page 01
-15
   
      If specified value "B1-S1 OK" is obtained:  
     
- Press -C- button. Basic Settin
g 
Q
Input displa
y group number XXX
    
When indicated on display:  
- 
Press buttons -0-, -4- and -4- to select "display group number 044" 
Pa
ge 31 of 47 Readiness code11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.01.7