heating AUDI A8 1997 D2 / 1.G AEB Engine Motronic MFI And Ignition System
Page 41 of 135
24-29
      
-  Compare display and specified values (display 
fields 1 and 2): 
  
Display fields  
  
1   2   3   4  
Display group 41: Oxygen Sensor (O2S) heating  
Display  
xx.x   
Htg.bC.ON/Htg.bC.OFF  
xx.x   
Htg.aC.ON/Htg.aC.OFF  
Indicates   Resistance of oxygen 
sensor heater  
(before TWC)  O2S heater on  
or  
O2S heater off  
(before TWC)  Resistance of oxygen 
sensor heater  
(after TWC)  O2S heater on  
or  
O2S heater off  
(after TWC)  
Range  
0.0-65.0   
---   ---   ---  
Specified 
value  4.9-19.9   
Htg.bC.ON   ---   ---  
  
If not as specified   Page 24
-30
 , Continuation  
---   ---  
      If displayed values are OK (as specified):  
     
- 
Press  button to advance program 
sequence.      
- 
Press buttons -0- and -6- to select "End Output" 
function 06, and press -Q- button to confirm 