check engine AUDI A8 1998 D2 / 1.G AHA ATQ Engines Secondary Air System Workshop Manual
Page 3 of 10
26-13
      
Flow test 
      During the flow test, the oxygen sensor control is 
switched off (engine runs rich at that time). At the 
same time the secondary air injection pump is 
switched on, injecting fresh air into the exhaust 
manifold which increases the oxygen content in 
the exhaust gas. The oxygen sensor now 
measures a lean mixture. To pass the diagnostic 
test, the oxygen sensor must measure a lean 
mixture for a certain time. Passing the test 
means that the secondary air injection system 
delivers enough air and the secondary air 
injection system is OK.  
     
Leak test 
     
Flow test must check out OK 
     Engine at operating temperature 
      The secondary air injection pump is switched on 
during idle. Since the combination valves are not 
triggered by the secondary air injection solenoid 
valve, they remain closed. When the secondary 
air injection pump is switched on, the oxygen 
sensor system is monitored by the ECM. If the 
system does not leak, fresh air cannot enter the 
exhaust manifold. If the system is leaking, the 
oxygen sensor signal will respond to the leaner 
mixture (caused by the secondary air getting into 
the exhaust manifold) and cause a noticeable 
Pa
ge 3 of 10 Secondar
y Air In
jection 
(AIR
) system
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE03.26.2